CORNER POST FENCE NOTES:
\ 7620 CONNECTION REFER NOTE 11 1. REFER TO DRAWING 017866201 SHEET 1
A \ FOR ADDITIONAL CONNECTION DETAILS. JA
| 2. ALL EARTH STRAPS TO BE 50 x 3mm HOT
7 é—, 7 + / / 7 7 Zz z / 7 Z 7 / , DIPPED GALVANISED MS FLAT AND LAID TO
TO TELSTRA SERVICE EARTH MINIMUM DEPTH OF 500mm.
PROPOSED 35mm? GIY EARTH CABLE ee PmTTELSTRA EXCHANGE SEBI \ 3, TELSTRA EXCHANGE SITES WILL HAVE AN
INCONDUIT. ALSO REFER TO NOTE 16 EA EXISTING STRUCTURE BASE EXISTING EARTHING SYSTEM PRESENT
eA (WHICHEVER IS CLOSER) / CHECK RECORDS FOR LOCATION.NOTE =
eA — =o \ THAT THERE MAY BE AN OBSOLETE SYSTEM
—_— = IN SITU, TESTING WILL BE REQUIRED TO
ENSURE THAT EARTHING SYSTEM IS IN
EA —— — —— EA — — — FA — — — EA — — — SERVICE.
4. SEBISPC FOR SAN INSTALLATION SHALL BE
B PROPOSED 35mm? GIY CABLE IN FLEXIBLE EARTH PIT WITH ELECTRODE G CONNECTED TO EXISTING SERVICE EARTH |B
GREY CONDUIT. REFER TO NOTE 14 e { VIAABOLTED CONNECTION THAT CAN BE
/ _— \ BROKEN FOR EARTH SYSTEM TESTING. THE
co BOND IS TO BE UNDERTAKEN EXTERNAL TO
7 THE BUILDING AND MUST NOT RUN VIA
| 4 EQUIPMENT AREAS.
m 5. STANDARD ELECTRODES TO BE STAINLESS [-]
Z oO STEEL CLAD ROD (S/I 446/16) 1440mm LONG
| } AT SPACING OF MINIMUM 2 ELECTRODES
8 | DEEP.
* 8 TO MAST SEB 6. ALL ELECTRODES ARE TO BE INSTALLED AND
¢ > © PLACED WITHIN P1/P2 INSPECTION PIT. a
| 7. 19/.53mm GREEN AND YELLOW COPPER
CABLE SHALL RUN FROM THE PROPOSED
“ ‘ SEB/SPC FOR SAN INSTALL, TERMINATE AT
| UNISTRUT CABLE PATHS (2 OFF) SHALL | ELECTRODE AND CONTINUE TO EXISTING
BE BONDED TO ANTENNA MAST EARTH m SERVICE EARTH SYSTEM
— \ | BAR IN A PIGGY BACK ORIENTATION ° \. 8. REFER TO EARTHING GUIDELINES SHEET
J | G4-2 AND G4-3
m 9. ALL CONNECTIONS TO EARTH ELECTRODES
, 90 AND JOINTS ARE TO BE TREATED WITH
} SEBISPC SHALL BE MOUNTED AT LOWER CORNER POST FENCE | DENSO PASTE AND TAPE.
LEVEL ON H-FRAME VIA INSULATORS CONNECTION 0. WHERE ELECTRODES CAN NOT BE DRIVEN
D REFER NOTE 11 OR EARTH RESISTIVITY IS HIGH, DRILLING |p
MAY BE REQUIRED. PRE-DRILLED HOLES
CORNER POST FENCE CONNECTION SHALL BE BACK FILLED WITH EARTH
REFER NOTE 11 ENHANCING COMPOUND (E.G CALCIUM
BENTONITE AND GYPSUM SLURRY)
/ / / 7 / / / 7 7 / 1, ALL FOUR FENCE CORNER POSTS SHALL BE
CONNECTED TO THE SAN EARTH a
12. CABLES ANDIOR CONNECTIONS FROM
EARTHING - PLAN VIEW NOTES (CONT'D): EARTH ELECTRODE SCHEDULE EXISTING TELSTRA EARTHING SYSTEM SHALL
- 13. EARTH CABLE LUGS SHALL HAVE HEAT TYPE DIAMETER] QUANTITY] DEPTH BE LABELLED IN RESPECTIVE EARTH PITS TO
SCALE 1:25 SHRINKS TO COVER LUG BARREL EXTENDING STAINLESS STEEL CLAD) 44, 3 288m IDENTIFY CONNECTION TO SAN EARTH.
OVER CABLE. ROD : ALL OTHER EARTH CABLES THAT CANNOT BE
E 14, PROPOSED 35mm? G/Y INSULATED EARTH EARTH GRID SCHEDULE VISUALLY TRACED FROM SEB TO E
CABLES INSTALLED WITHIN SAN COMPOUND GRID SCHEDU DESTINATION MUST ALSO BE LABELLED.
LEGEND: AMONG EARTH BARS AND FENCES/EARTH TYPE DIMENSIONS
ELECTRODES SHALL RUN IN FLEXIBLE GREY HOT DIPPED GALVANISED MS FLAT 50 x 3mm
oor oman EA CONDUIT TO BE INSTALLED UNDER NOTE: THIS DRAWING TO BE READ IN CONJUNCTION WITH SHEET G4-2 FOR CONSTRUCTION
ABOVE GROUND 16mm? EARTH E GEOTEXTILE MAT AND 100mm COMPACTED * "
BELOW GROUND 35mm? EARTH — — — £ — __ROADBASE. ORDER | DRAWN] CHKD AMENDMENT exa | aPeD | DATE [188 t ‘elstra LH
BELOW GEOTEXTILE MAT. EC 15, FENCE AND GATE POST CONNECTIONS ARE TO [57168] NL | HH |FC-SP30096252WOOS4DECON-SATELLITE | RC | IT | 23.03.23] 1
: BE TREATED WITH DENSO PASTE AND TAPE.
35mm? EARTH IN FLEX GREY CONDUIT 416. IF INTERCONNECTION OF SAN GROUND ROD TO SATELLITE ACCESS NODE SITE 182703
EARTH INSPECTION PIT Ce) TELSTRA GROUND/TOWER STRUCTURE EARTH NOOSAVILLE EXCHANGE & RT
F SITE FENCING / / CANN Sia BE CONRECIED RECTLY SITE EARTHING (OPTION 1)
EARTH ELECTRODE ot TO THE H FRAME GROUND BAR AS AN 88 GOODCHAP STREET, NOOSAVILLE, QLD 4566
DWG SHT
SERVICE EARTH BAR SEB ALTERNATIVE ©elstra Corporation Limited ABN 33 051 775556. All rights reserved NO. Q757 4 68 | NO. Ge
1 I 2 I 3 7 4 I 5 Cad fle, O757 168.49 A3

 

 

The copyright and cumership of tis drawing assigned io Telstra and must not be copied or saved elsewhere without writen permission from Tals,
Log in to download the original file

fc Noosaville Exchange & rt.pdf · 6.1 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.