FRAMING SCHEDULE - SHEET ROOF ALL GIRDER TRUSS TIE-DOWN SHALL
BE IN ACCORDANCE WITH
WIND CLASSIFICATION MANUFACTURER’S SPECIFICATIONS
MAXIMUM ROOF LOAD WIDTH - 5800mm NOGGINGS - 1350mm CRS MAXIMUM
STUD HEIGHTS & SIZES
ALL STUDS NOT NOTCHED

2450 - 90x35 MGP12 @ 450 CRS
2700 - 90x35 MGP12 @ 450 CRS STUDS AT OPENINGS
3000 - 90x35 MGP12 @ 450 CRS OPENING WIDTH No. OF STUDS
3600 - 90x35 MGP12 @ 450 CRS Oy
4200 - 2/90x45 MGP10 @ 450 CRS 900
4500 - 2790x45 MGP1S @ 450 CRS 1200 2

1500 2
TOP PLATES - 2/90x45 MGP12 1800 2

2100 2
TIE-DOWN SPACING - 1200mm 24.00 3

2700 3
BOTTOM PLATE - 90x35 MGP12 3000 3

3200 3
TRUSS TIE-DOWN - Mi2 RODS AT 3900 5
CORNERS, EACH SIDE OPENINGS. 4.800 5
ROOF BATTENS .
METAL ROOF BATTENS FIXED IN
ACCORDANCE WITH MANUFACTURER'S
SPECIFICATIONS
RAFTERS & ROOF TRUSSES SHALL BE TIED
DOWN WITH 1/30 x 0.8 mm Gl STRAP

S/S

 

 

 

18 m

1.8 m

 

 

 

 

 

 

BRACING LEGEND

INDICATES M12 CYCLONE ROD :

 

}
INDICATES M16 CYCLONE ROD {

INDICATES M16 BOLT i

INDICATES 180mm LENGTH OF STRUCTURAL PLY BRACING WALL (6.4kN/m). 4.5mm F27 EXTERNAL PLY SHEETING FIXED

TO ONE SIDE OF STUD WALL, STUDS TO BE AT 600mm CENTRES MAXIMUM. VERTICALLY INSTALLED SHEETING TO BE

NAILED TO TIMBER FRAME WITH 30mm x 2.8-3.15@ CLOUTS OR FLATHEAD NAILS. NAILS ARE TO BE LOCATED AT 150mm
AROUND ALL EDGES AND BUTT JOINTS AND AT 300mm CENTRES ALONG INTERMEDIATE STUDS. PROVIDE M12 CYCLONE

ROD WITHIN SOmm OF EACH END OF THE BRACING WALL CONTINUOUS FROM TOP PLATE TO SLAB/FLOOR FRAMING AND
M12 BOLTS FROM BOTTOM PLATE TO SLAB/FLOOR FRAMING AT 1200mm CENTRES MAXIMUM IN BETWEEN.

INDICATES 1800mm LENGTH OF GYPROCK BRACING WALL (3.4kN/m). 10mm PLASTERBOARD LINING FIXED TO ONE SIDE OF
STUD WALL, STUDS TO BE AT 600mm CENTRES MAXIMUM. TOP AND BOTTOM PLATES TO BE &5mm DEEP. HORIZONTALLY
INSTALLED SHEETING TO 8E NAILED TO TIMBER FRAMING, WITH &Omm PLASTERBOARD CLOUTS. CLOUTS ARE TO BE
LOCATED AT 100mm CENTRES ALONG TOP AND BOTTOM PLATES AND SHEET EOGES AND AT 225mm CENTRES ALONG
INTERMEDIATE STUDS. PROVIDE M12 CYCLONE RODS WITHIN SOmm OF EACH END OF THE BRACING WALL CONTINUOUS
FROM TOP PLATE TO SLAB/FLOOR FRAMING AND AT 1800mm CENTRES MAXIMUM IN BETWEEN.

INDICATES 1800mm LENGTH OF EXTERNAL FIBRE CEMENT BRACING WALL. (&.4kN/m) 4.Smm HARDIFLEX OR 6mm F.C. SHEETS
EXTERNAL CLADDING FIXEO TO ONE SIDE OF, STUD WALL, STUDS TO BE AT 600mm CENTRES MAXIMUM. VERTICALLY
INSTALLED CLADDING TO BE NAILED TO TIMBER FRAMING WITH 30mm x 2.0 FIBRE CEMENT NAILS (GALVANISED). NAILS
ARE TO BE LOCATED AT 150mm CENTRES ALONG CLADDING SHEET EDGES AND AT 200mm CENTRES ALONG INTERMEDIATE
STUDS. PROVIDE: M12 CYCLONE ROD WITHIN SOmm OF EACH END OF BRACING WALL: CONTINUOUS FROM TOP PLATE TO
SLAB/FLOOR FRAMING AND Mi BOLTS FROM BOTTOM PLATE TO SLAB/FLOOR FRAMING AT 1200mm CENTRES MAXIMUM IN
BETWEEN.

‘e INDICATES 150mm BLOCK WALL WITH A RACKING RESISTANCE OF 13.4kN. Y12 RODS TO BE PLACED VERTICALLY AT
CORNERS, EACH SIDE OF OPENINGS AND AT 1800 CENTRES MAXIMUM IN BETWEEN. PROVIDE 2 COURSE (MIN) BOND BEAM
CONTINUOUS AT TOP OF BRACING WALLS.

WALLS BRACED WITH STRUCTURAL PLY BOTH SIDES ACHIEVE A RACKING
RESISTANCE OF 12.8kN/m. (NOTE M16 RODS REQUIRED EACH END}

WALLS BRACED WITH PLASTERBOARD BOTH SIDES ACHIEVE A RACKING
RESISTANCE OF 6.4kN/m . : -

INDICATES 300% R.C. COLUMN WITH A RACKING RESISTANCE OF SkN IN EACH
DIRECTION. .

CANTILEVERED POST BRACING FORCE IN EACH DIRECTION. FORCES SUITABLE FOR DIA
450 X 900 DEEP CONCRETE FOOTINGS. REFER TABLE BELOW FOR VALUES

POST HEIGHT BRACING FORCE
RESISTED

0 TO 600 mm 6 KN

600 TO 1200 mm 5 kN

1200 TO 1800 mm 4 kN

 

 

 

 

 

 

 

LINDSA Y CONSULTING {i

  

=
-_
TT
= hg
oS
~~
mae
n
nw
a
4
a
< iad
wa
295
z| 3°
olf <t
=| io &
=| 5 &
48 <
aw o
-| O fF <
wl a ~”
soe Oo
oj] &o &
ea Z&
a
e| >
a| 2
zl ©
|=
Pn x
PK] |;
N a
€

SINT CLV IL BAR CaN EY

Ne

Cit ke Z

    

OFF. 2C/82 PARKER STREET, MAROOZHYDOR

      

 

 

 

 

Used in these records

About this file

File size
3.2 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_1098 - MCU - Detached House [As Published].pdf · 3.2 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.