Council archive · source document
07/2446 - 6 Copies of environmental noise level study [As Published] · 132007.2446
Mixstone Pty Ltd Environmental Noise Level Study for Proposed Residential - Budget Accommodation - Development, 102 Pacific Avenue, Sunshine Beach Page 11 of 19 As the noise limits are complied with/effectively complied with for the complete 24-hour day at the closest adjoining residence, which is to the north-west, the noise limits would also be complied with at all other adjoining residences, also for the complete 24-hour day. Plant Noise Plant noise from the proposed budget accommodation could include the spa pool pump and blower and airconditioning units. Whilst at the time of preparing this report no detail was available with respect to plant it has been assumed that the Dorms would be airconditioned, along with the Manager's Unit and Reception. Based on previous noise assessments conducted by the consultant typical plant noise levels would be: e spa blower: 85 dB(A) @ 1 metre; ¢ poo! filter/pump: 65 dB(A) @ 1 metre; ¢ —airconditioner: 55 dB(A) @ 1 metre. At the closest adjoining residence, which is to the north-west, the noise level of the above would be: e spa blower: 85 dB(A) @ 1 m - 22 (distance) — 20 (enclosure/room) = 43 dB(A); © pool filter/pump: 65 dB(A) @ 1 m - 22 (distance) — 20 (enclosure/room) = 23 dB(A); ¢ airconditioner: 55 dB(A) @ 1 m - 22 (average distance) + 8 (multiple airconditioning units operating concurrently, up to 8 units) = 41 dB(A). The noise limits for plant noise are: e daytime: 47 +5=52 dB(A); * evening: 43+ 5=48 dB(A); « night-time: 40 + 3 = 43 dB(A). Assuming that the spa blower will not operate during the night-time but the pool filter/pump and airconditioning units would operate during the night-time the combined noise level for these noise sources would be 23 + 41 = 41 dB(A), which complies with the noise limits for the complete 24-hour day. As the noise limits are complied with for the complete 24-hour day at the closest adjoining residence, which is to the north-west, the noise limits would also be complied with at all other adjoining residences, also for the complete 24-hour day, for plant noise. CONCLUSIONS It is proposed to partially remove the existing structures from the subject site at 102 Pacific Avenue, Sunshine Beach and develop the site with residential (budget accommodation). Based on the consultant's site inspection, the only potential environmental noise impact upon the subject site is traffic noise from Pacific Avenue, a Council controlied road. Noise from the subject site could include vehicle activities, people laughing and talking and plant and equipment. To assess traffic noise impact upon the subject site a 24-hour noise level study was conducted from Monitoring Location A, on the front (Pacific Avenue) boundary of the subject site with the microphone elevated 2 metres. To assess the general ambient noise levels for this residential area and establish appropriate noise limits for noise from the subject site a 24-hour ambient noise assessment was conducted over a weekend from monitoring location B from adjacent the rear boundary of the subject site - boundary most distant from the influence of traffic noise from Pacific Avenue, with the microphone also elevated 2 metres. The noise limits based on these ambient noise levels were used for noise from people laughing and talking and plant noise. David Moore & Associates Pty Ltd - “3 Our reference: R09043/D2260/Rev.0/23.04.09 + 4 4 oi
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2446 - 6 Copies of environmental noise level study [As Published]Related documentApplication case desk ↗
About this file
- File size
- 1.7 MB (small file)
- File type
No other editions are linked here.