Skip to the record
Noosa’s premier civic archive.

Original source · versioned page text

Reference Document MCU22-0102 Stormwater Management Plan

of 119

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Very large file: it may take a few minutes

The original of this document is very large (29.9 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
               HOW IT WORKS
               Section of the SPEL HydroChannel:                       Modular Design
               1)	Water comes from the surface to the SPEL            Based on the innovative filtration solution is the
                      HydroChannel                                     concrete nominal width of 300mm. Planners
               2) 	The sedimentation chamber removes coarse           are not required to make any alternations in the
                      solids, such as gravels, chippings, leaves and   drainage plan if they want to treat the water with the
                      other solids. The rubber seal ensures a water    HydroChannel.
                      tight seal is maintained.                        The modular interior of the HydroChannel:
               3-4) 	The pre-treated water pass through the           1) 	The sedimentation box is primary treatment
                      granular filter bag, and the organic and                   capturing solids such as stones, leaves,
                      inorganic pollutants are removed.                          and suspended particles on. The rubber
               5)	The filtered water flows over the baffle into                 lip ensures sealing around the edges – for
                      the free flow area of the channel. It can                  the reliable differentiation for subsequent
                      then be re-used, or discharged to surface or               filtration.
                      ground water via infiltration.                   2) 	The pretreated rainwater passes through
                                                                                 the granular-filter-pad and the organic and
Drain:                                                                           inorganic pollutants will be filtered from the
                                                                                 water.
the surface
er Drain
                             1                                         3) 	     The filtered water flows over the baffle into
                                                                           Section 3P Hydro Filter Drain:
                                                                                 the free flow area of the channel and is
                                                                           1) Water comes from the surface
chamber                                                                        todischarged              per normal site1requirements.
                                                                                   the 3P Hydro Filter Drain

 lids, such                                                                 2)    The sedimentation chamber
                                                                                  removes coarse solids, such
gs, leaves                                                                        as gravels, chippings, leaves
                                                                                  and other solids. The rubber
he rubber                                                                         seal ensures a water tight
er tight                                                                          seal is maintained.
                                                                                                                  2
                        2                                                   3-4) The pre-treated water pass
                                                                                 through the granular filter
                                                                                 bag, and the organic and inor-
                                                                                                                          3
ter pass                                                                         ganic pollutants are removed.
ar filter                               3                                    5)    The filtered water flows over         4
 c and inor-                                                                      the baffle into the free flow
                                                                                  area of the channel. It can
e removed.                                                                        then be re-used, or dischar-            5
 ows over                         4                                               ged to surface or ground
                                                                                  water via infiltration.

ree flow
 . It can
 dischar-                                5
round
n.




                                                                          3P Technik Filtersysteme GmbH
                                                                          Öschstraße 14
                                                                          73072 Donzdorf
                                                                          T +49 (0) 71 62 - 94 60 7-0
                                                                          F +49 (0) 71 62 - 94 60 7-99
                                                                          [email protected]
                                                                          www.3ptechnik.com




         4       SPEL Hydrochannel
Log in to download the original file

Reference Document MCU22-0102 Stormwater Management Plan.pdf · 29.9 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.