FLOOR AREAS:
3 5 1 LOWER LIVING 135.40 m²
UPPER LIVING 88.13 m²
18930
4 GARAGE 39.83 m²
PATIO 4.43 m²
N
1540 2730 6180 2090 5590 800
PORCH 1.85 m²
90 90 90 90
TOTAL DWELLING AREA 269.63 m²
6000 2000 5500
70 70 90
4710 1220 930 1000 5500 800 GRANNY VERANDAH 106.56 m²
250
GRANNY LIVING 64.80 m²
250
D2106 D2106 D2106 D2106 TOTAL RELATIVES RESIDENCE AREA 171.36 m²
90
FIREPLACE Total 440.99 m²
SIZE TBA
gas struts
A0612
2200
x2
D1809 C1 C1 WALL LEGEND
90
EXTERNAL WALLS
1270
5870
5800
LOUNGE - CLADDING - TO BUILDER'S SPEC.
- 90mm TIMBER STUD FRAME (UNO)
CH3000mm
F2115 2131STK-SGD - 10mm PLASTERBOARD LINING (GENERAL)
90
3090
- 10mm 'WET STOP' OR EQUIV' (WET AREAS)
1300
LINE OF UPPER FLOOR INTERNAL WALLS
- 70mm TIMBER STUD FRAME (UNO)
L1806 - 10mm PLASTERBOARD LINING (GENERAL)
90
STEP
DINING - 10mm 'WET STOP' OR EQUIV' (WET AREAS)
STEP UP
REFER TO ENGINEERS DETAILS FOR
70
820
F1815
1700
SEAT
ARTICULATION JOINTS IF REQUIRED
530 1130 70
C2 D1809
ST TEP
EP
90
S
BOOKSHELF ON HINGES
1640
STEP
1200
1130
LEGEND:
920
CH2700mm STEP
POR ENTRY
14100
70
300
6800
90
720cs C1 DENOTES - 75x75 SHS POST
70
90
820 DISPLAY C2 DENOTES - 100x100 HWD POST
820fs
5680
D1809
storage
910
S DENOTES - PHOTOELECTRIC SMOKE ALARM
1130
PWDR
D1806
70
900x3000 TO NCC VOL 2, 3.7.5 & AS 3786
mv
70
(MAINS POWERED & INTERCONNECTED)
70
3730
3380
3200
BED 4 G DENOTES - GAS BOTTLE/HWS LOCATION AS PER
720cs
D1809
HW AS 5601
2200
KITCHEN
2000
robe
D1806
WIP
FLOOR PLAN NOTES:
720cs
LINE OF UPPER FLOOR TERMITE PROTECTION IS TO BE PROVIDED IN ACCORD.
70
90
820fs
6000
90
D1806 F0624 WITH NCC VOL 2, 3.1.4 AND AS 3660.1.
1230
1300
ENS GARAGE 1500hh
PROVIDE A STATEMENT OF PROTECTION METHOD FROM A
TERMITE MANAGEMENT PROFESSIONAL IN CONJUNCTION
WITH THESE DRAWINGS AT THE TIME OF SUBMISSION FOR
90
BUILDING APPLICATION APPROVAL.
3310
D0906
3400
900
obsc LDRY
TOILET DOORS TO BE PROVIDED WITH LIFT-OFF HINGES,
2100
OPEN OUTWARDS OR SLIDE UNLESS CLEAR SPACE OF
1.2m TO WC PAN
INSECT/SECURITY SCREENS TO WINDOWS AND DOORS
ARE AS PER BUILDERS SPECIFICATIONS UNO
90
90
820
2148PLD CONSTRUCTION IS NOT TO COMMENCE PRIOR TO FULL
APPROVAL BEING GRANTED IN WRITING BY THE CERTIFIER
90 70 70 70 90 AND LOCAL AUTHORITY
4200 2130 1530 2200
70 90 90 OPENING WINDOWS IN BEDROOMS MUST BE PROVIDED
3600 530 6000 2000 6300 WITH PROTECTION AS PER NCC 3.9.2.6 IF 2M OR MORE
ABOVE THE SURFACE BENEATH
90
2660 TREADS, RAMPS AND LANDINGS MUST HAVE A SLIP-
RESISTANCE CLASSIFICATION NOT LESS THAN LISTED IN
90 6000 2000
APPROVED PLANS NCC VOL 2 TABLE 3.9.1.4
1540 2730 8270 6390 MCU21/0150 MECHANICAL VENTILATION (mv) TO BE IN ACCORD.
WITH THE NCC VOL 2, 3.8.5, 3.8.7 & AS 1668.2
NOOSA COUNCIL (DISCHARGE TO EXTERNAL AIR)
16 DECEMBER 2021
DWELLING LOWER FLOOR PLAN INTERNAL GARAGE DOOR TO BE SEALED AS PER NCC
VOL 2, 3.12.3.3
1 : 100 GAS BOTTLE LOCATION AS PER AS5601
THESE DRAWINGS AND DESIGN ARE ISSUE DATE DRWN CHKD COMMENTS DATE
COPYRIGHT AND WILL NOT BE USED
PROJECT JOB SPECIFICATION BY BUILDER TAKES
OR REPRODUCED BY ANY MEANS,
* 19/08/2021 RW RW CONCEPT FLOOR PLANS
PROPOSED RESIDENCE PRECEDENCE OVER THESE PLANS DWELLING LOWER FLOOR PLAN
WHOLLY OR PARTLY WITHOUT PRIOR A 01/09/2021 RW RW AMENDMENTS - CONCEPTS
CLIENT SALES PROJECT STATUS
WRITTEN PERMISSION FROM - B 02/10/2021 RW RW AMENDMENTS - CONCEPTS
BESPOKE BUILDING DESIGN PRELIMINARY DRAWINGS
Livable|Sustainable|Accessible|Desirable C 04/11/2021 RW RW AMENDMENTS - CONCEPTS
CLIENT LOCATION SCALE SHEET SIZE CLASS WIND ISSUE
P: (07) 41289065 DO NOT SCALE FROM THIS DRAWING D 15/11/2021 RW RW PRELIMINARY DRAWINGS
VERIFY ALL DIMENSIONS PRIOR TO E 23/11/2021 RW RW SHED AND TANKS MOVED LOT 190 ON MCH1261 INDICATED A3 1a E
E: [email protected]
COMMENCEMENT OF ANY SITE WORKS
PO Box 7330, Urangan QLD 4655 9 RULES ROAD DRAWING FILE NUMBER PAGE
QBCC 1257937
AND REFER ANY DISCREPANCIES TO
BESPOKE BUILDING DESIGN POMONA, QLD B210717 3
Document Set ID: 21734642
Version: 2, Version Date: 16/12/2021
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.