Original source · versioned page text
ECM_21734642_v2_Approved Plans MCU 21 0150
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn APPROVED PLANS
25° MCU21/0150
NOOSA COUNCIL
16 DECEMBER 2021
UF CL COLORBOND FASCIAS
5650 AND GUTTERS
UF WH
5200 COLORBOND ROOF SHEETING POWDERCOATED ALUM
FIXED TO MANUF. SPECS. WINDOWS AND DOOR FRAMES
7964
3°
UF FL
GF CL 3100
2700
GF WH
2100
1500
GF FL
SUNKEN FL 0
-300 2.1x4.8 PANEL-LIFT-DOOR
NOTES:
ELEVATION 1 SELECTED TIMBER FRONT
ENTRANCE DOOR
ELEVATION 2 GANGNAIL TRUSSES TIED DOWN, BRACED, FABRICATED
AND INSTALLED TO TRUSS MANUFACTURERS
1 : 100 1 : 100 SPECIFICATIONS.
100x100 TIMBER POST
ON GAL. STIRRUP (PORCH)
FLASHINGS TO WALL OPENINGS TO COMPLY WITH NCC
VOL 2, 3.5.4.6
DECKS & BALCONIES TO BE FIXED TO EXTERNAL WALLS AS
PER NCC VOL 2, 3.10.6
STAIR CONSTRUCTION TO BE IN ACCORDANCE WITH
NCC VOL 2 PART 3.9.1.2
BALUSTRADE TO BE 1M ABOVE FFL IN ACCORD. WITH
NCC VOL 2, 3.9.2.2 AND AS 1170.1.
OPENING WINDOWS IN BEDROOMS MUST BE PROVIDED
WITH PROTECTION AS PER NCC VOL 2, 3.9.2.6 IF 2M OR
MORE ABOVE THE SURFACE BENEATH
OPENING WINDOWS IN ROOMS OTHER THAN
BEDROOMS MUST BE PROVIDED WITH PROTECTION AS
'LINEA' WEATHERBOARD PER NCC VOL 2, 3.9.2.7 IF 4M OR MORE ABOVE THE
5°
CLADDING (or similar) SURFACE BENEATH
UF CL
TREADS, RAMPS AND LANDINGS MUST HAVE A SLIP-
5650 UF WH RESISTANCE CLASSIFICATION NOT LESS THAN LISTED IN
5200 NCC VOL 2, TABLE 3.9.1.4
BALUSTRADING TO NCC VOL
2 PART 3.9.2 & AS1170.1
UF FL
GF CL 3100
2700
GF WH
2100
GF FL
0 SUNKEN FL
-300
ELEVATION 3 75x75 SHS POSTS
ELEVATION 4
1 : 100 1 : 100
THESE DRAWINGS AND DESIGN ARE ISSUE DATE DRWN CHKD COMMENTS DATE
COPYRIGHT AND WILL NOT BE USED
PROJECT JOB SPECIFICATION BY BUILDER TAKES
OR REPRODUCED BY ANY MEANS,
* 19/08/2021 RW RW CONCEPT FLOOR PLANS
PROPOSED RESIDENCE PRECEDENCE OVER THESE PLANS DWELLING ELEVATIONS
WHOLLY OR PARTLY WITHOUT PRIOR A 01/09/2021 RW RW AMENDMENTS - CONCEPTS
CLIENT SALES PROJECT STATUS
WRITTEN PERMISSION FROM - B 02/10/2021 RW RW AMENDMENTS - CONCEPTS
BESPOKE BUILDING DESIGN PRELIMINARY DRAWINGS
Livable|Sustainable|Accessible|Desirable C 04/11/2021 RW RW AMENDMENTS - CONCEPTS
CLIENT LOCATION SCALE SHEET SIZE CLASS WIND ISSUE
P: (07) 41289065 DO NOT SCALE FROM THIS DRAWING D 15/11/2021 RW RW PRELIMINARY DRAWINGS
VERIFY ALL DIMENSIONS PRIOR TO E 23/11/2021 RW RW SHED AND TANKS MOVED LOT 190 ON MCH1261 INDICATED A3 1a E
E: [email protected]
COMMENCEMENT OF ANY SITE WORKS
PO Box 7330, Urangan QLD 4655 9 RULES ROAD DRAWING FILE NUMBER PAGE
QBCC 1257937
AND REFER ANY DISCREPANCIES TO
BESPOKE BUILDING DESIGN POMONA, QLD B210717 5
Document Set ID: 21734642
Version: 2, Version Date: 16/12/2021
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.