Att11 - Land Suitability (effluent) Report
Very large file (13.4 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Low plume (<500mm),
Distribution laterals with above ground
Installation Notes:
large / heavy droplet dome Max spacing
sprinkler with max spray 4000mm. sprinkler heads.
diameter of <2000mm. 1. This drawing must be read in conjunction with the corresponding
Minimum of 150mm cover material. Future-Plus Environmental report.
2. All work must comply with AS/NZ 1547, Queensland Plumbing and
N.S.L Wastewater Code, Standard Plumbing and Drainage Regulation 2003,
Plumbing and Drainage Act 2002 and local government guidelines.
150mm min
3. There is to be sufficient fall from the existing / proposed facilities to the
treatment plant to enable sanitary drains to gravity feed to the connection
point.
4. Delivery pipe should be lilac stripe 25mm or similar polypipe and
should be buried to a minimum depth of 150mm in good quality natural or
imported topsoil.
5. A filter is to be installed on the delivery pipe to prevent clogging.
6. A check valve is to be installed on the delivery pipe.
7. A distribution valve is to be installed (upslope of the irrigation area) to
For clay soils, the irrigation area is to be Irrigation area is to be planted with provide even distribution to the irrigation area(s) and to the laterals.
scarified and treated with 1kg/m2 of non-intrusive, water-tolerant trees, shrubs, 8. Any depressions within the irrigation area are to be filled with soil of the
gypsum. groundcovers and / or turf to maximise same category as Horizon A.
nutrient uptake and evapotranspiration.
9. Laterals must be laid parallel with the natural contours of the land.
10. Control valves are to be placed on each sprinkler to ensure even
distribution.
11. Sprinklers should be spaced no more than 4000mm apart and no less
Diversion Drain /
Mound
than 2000mm from the irrigation area boundary.
12. Irrigation areas should be ripped to a minimum depth of 400mm
Low plume (<500mm),
where possible.
Cut Off Drain
large / heavy droplet dome 13. A diversion drain / mound is to be constructed upslope of the irrigation
sprinkler with max spray area.
diameter of <2000mm. 14. A retention mound is to be constructed downslope of the irrigation
area.
15. All stormwater is to be diverted away from the proposed irrigation
area.
16. If applicable, any existing sewage treatment plant(s) and effluent
Sloping Site - greater than 1:10 disposal system is to be decommissioned.
Where slope exceeds 10%, advice is to be sought from FPE prior to installation. 17. Where not already established, the irrigation area is to be planted with
non-intrusive vegetation that is tolerant to wet conditions and has a high
evapotranspiration capacity. Seek advice from your local nursery.
18. Where not already established, turf or mulch is to be applied to the
STANDARD DRAWING irrigation area.
Surface Spray Irrigation System 19. The boundary of the irrigation area should be clearly delineated (e.g.
through planting) to deter human and animal access.
20. All vehicles and hooved animals are to be kept off the irrigation area.
21. A minimum of two warning signs should be placed within each
Not to Scale. irrigation area with wording such as ‘Recycled Water – Avoid Contact –
FPE Ref: WW02
Figure measurements to take precedence over scale DO NOT DRINK’.