07/0967 - MCU - Detached House [As Published] · 132007.967
Window & Door Schedule
4 “a
All doors and window sizes are approximate and are to be checked on site.
All doors and windows in westem red cedar or surian cedar timber.
Coat all timber with 1 coat of Sikkens Cetol + 2 coats Sikkens Super Natural
Prime all timber before or as soon as it arrives on site.
Use 140 x 42 frames, unless otherwise stated.
Allow for black framed aluminium fly screens to all louvred windows inset to outside.
Use safety glass to bathroom and other areas as required.
Use 152 glass louvre blades or 102 timber blades with Hardies mechanism in black.
Allow for a 200 x 50 Hebel sill mould to each window where shown.
Lower level - set windows and doors to 2700mm, unless noted otherwise.
All doors and windows to suit W41 wind loads, or as per engineer's requirements.
** All measurements are height x width.
GROUND LEVEL DOORS
01 2700 x 2400 feature timber framed pivot door with glass panels
each side, refer to joinery drawings
D2 2700 x 920 timber framed hinged glass doors, 1 lite
D3 2700 x 2500 x 4 panel OXXO 2 x timber framed hinged glass
doors with timber louvres each end
D4 2700 x 13600 x 6 panel XXX-XXX timber framed glass sliding
@ doors, on extended sliding track
5 2700 x 6400 x 3 panel XXX timber framed glass sliding
doors, on extended track
D6 2700 x 3700 x 4 pane) OOXO timber framed glass sliding door
with glass louvres each end
07 2700 x 600 + 4600 + 600 OOXO timber framed glass sliding door
with silicon butt comer with 3 horiz. mid rails each end
D8 2700 x 2500 x 4 panel OXXO 2 x timber framed hinged glass
doors with timber louvres each end
GROUND LEVEL WINDOWS
wi 3 x 800 x 800 awning windows, satina glass, set at 2400
Ww2 500 x 500 awning window, satina glass, set at 2200
W3 600 x 900 awning window, satina glass, set to bench
W4 2400 x 900 timber louvre, set to step
WS 2400 x 900 timber louvre, set to step
W6 2700 x 1200 glass louvres
W7 3 x 2900 x 900 fixed glass panels, no timber frame, chanel set into blockwork;
glass penetrating water
@: 2700 x 1200 glass louvres
w9 2700 x 500 + 2000 silicon butt comer with 3 horiz. mid rails
W10 900x 900 satina glass louvres set at 2200
W11 900 x 3600 x 3 panels of satina glass louvres
() RH RAINHEAD
$ SPITTER N
Opp DOWNPIPE
CSR COLORBOND SHEET ROOF
oP
SW STORMWATER ROOF PLAN
_FALLDIRECTION DOWN PIPES AND ROOF DRAINAGE LOCATIONS
ARE SUGGESTED ONLY AND BUILDER SHOULD VERIFY SIZE OF ALL
ENSURE ADEQUATE STORMWATER FALL AND ROOFS ON SITE
DRAINAGE AS REQUIRED
_/
. PAUL CLOUT DESIGN (7
GENERAL NOTES: GuENT NAME: TRUST CLOUT ”
4 PAUL CLOUT - SUITE 4, 44 MARY eT NOOSAVILLE ' Use written dimensions onty, DO NOT scale drawings. Contractors to verify all SITE aDoRESS: Lot 710 Shorehaven Drive, Noosa Waters
+ NOOSA * 1 dimensions on site prior to commencing works. Site location is Category W41
o~ PH: (07) 5440 5388 FAX: (07) 5440 5399 1 or as per engineers requirements. These drawings are to be read in conjunction DRAWING TITLE: ROOF PLAN & WINDOW SCHEDULE
EMAIL: [email protected] WEB: www.pauidoutdesign.com.au with engineer's design and details, the accompanying building specification and DRAWING DATE: 04/05/07 l SCALE: 1:100 DRAWING No:
t schedule of finishes. If in doubt, it \. IME.
lule of finishes. If in doubt, please request clarification. DO NOT ASSUI PRELIMINARY 02 . 0)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/0967 - MCU - Detached House [As Published]Related documentApplication case desk ↗
About this file
- File size
- 2.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.