   Form 15—Compliance Certificate for building Design or Specification
NOTE                                                   This is to be used for the purposes of section 10 of the Building Act 1975 and/or section 46 of the
                                                       Building Regulation 2006.
                                                       RESTRICTION: A building certifier (class B) can only give a compliance certificate about whether
                                                       building work complies with the BCA or a provision of the QDC. A building certifier (Class B) can
                                                       not give a certificate regarding QDC boundary clearance and site cover provisions.
1. Property description                                Street address (include no., street, suburb / locality & postcode)
This section need only be completed if
details of street address and property
                                                        26 Dolphin Bay Drive
description are applicable.                             Sunshine Beach, QLD                                                 Postcode 4567
EG. In the case of (standard/generic)
pool design/shell manufacture and/or
                                                       Lot & plan details (attach list if necessary)
patio and carport systems this section
may not be applicable.
                                                       In which local government area is the land situated?
The description must identify all land the              Noosa Council
subject of the application.
The lot & plan details (eg. SP / RP) are
shown on title documents or a rates notice.
If the plan is not registered by title, provide
previous lot and plan details.
2. Description of component/s certified
Clearly describe the extent of work covered by          Structural design of proposed new garage & stormwater drainage
this certificate, e.g. all structural aspects of the    infrastructure
steel roof beams.

                                                        This certificate does not apply to the following:
                                                            existing structure outside of proposed scope of work as per
                                                               reference documentation.

3. Basis of certification
Detail the basis for giving the certificate and the     Standards:
extent to which tests, specifications, rules,           AS/NZS 1170.0 (2002), AS/NZS 1170.1 (2002), AS/NZS 1170.2 (2011), AS
standards, codes of practice and other                  2870 (2011), AS 3600 (2009), AS 3700 (2011), AS 4678 (2002)
publications, were relied upon.

                                                        Loadings:
                                                        Roof Live Load – 3.0kPa
                                                        Driveway / Carport – 2.5kPa / 9kN
                                                        Wind Loading – N3

                                                        Geotechnical Conditions:
                                                        Footings have been designed in accordance with site investigation numbered
                                                        17/1057 by Global Testing

                                                        As per Noosa Council Decision Notice (Application Number
                                                        OPW18/0016), the following have been satisfied in the design covered in
                                                        this certificate:
                                                            a. have the capacity to cater for the expected stormwater flows in
                                                                accordance with Council’s Planning Scheme Policy PSP 5
                                                            b. will not result in additional ponding of stormwater on the subject
                                                                site, the road reserve or any adjoining property
                                                            c. will not result in any additional scour or damage to the subject site
                                                                or the adjoining reserve.
Full text of the other 1 page

Page 2

4. Reference documentation
Clearly identify any relevant documentation,         Drawings numbered 17058 – S01 to S05 revision B by Casswell
e.g. numbered structural engineering plans.          Consulting Pty Ltd




5. Building certifier reference number              Building certifier reference number



6. Competent person details                         Name (in full)
A competent person for building work, means a
person who is assessed by the building certifier     Troy Steven Casswell
for the work as competent to practise in an
aspect of the building and specification design,
                                                    Company name (if applicable)                               Contact person
of the building work because of the individual’s     Casswell Consulting Pty Ltd                                 Troy Casswell
skill, experience and qualifications in the
aspect. The competent person must also be           Phone no. business hours              Mobile no.                         Fax no.
registered or licensed under a law applying in
the State to practice the aspect.
                                                     0416 048 132                          0416 048 132
                                                    Email address
If no relevant law requires the individual to be
licensed or registered to be able to give the        [email protected]
help, the certifier must assess the individual as
having appropriate experience, qualifications or    Postal address
skills to be able to give the help.                  PO Box 62
If the chief executive issues any guidelines for     Coolum Beach, QLD                                                        Postcode 4573
assessing a competent person, the building
certifier must use the guidelines when              Licence or registration number (if applicable)
assessing the person.
                                                     REPQ 07685

7. Signature of competent person                    Signature                                                         Date
This certificate must be signed by the individual
assessed by the building certifier as competent.


                                                                                                                                 26/06/2018




LOCAL GOVERNMENT USE ONLY

                Date received                                                                    Reference Number/s

Used in these records

About this file

File size
142 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

180626_Revised Form 15 Certificate.pdf · 142 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.