1 into 5 Lot Subdivision A
83 Butler St Tewantin QLD
NBN Co PIT AND PIPE DESIGN
Pit types Conduit depths and cover Clearances from other carriers and services
Type Symbol Description Location Minimum Cover Service item Minimum radial clearances*
P2 PIT-ID Service Drop Access Pit Service Drop conduit - Gas pipe over 110 mm 300 mm
B 300 mm B
2 (650mmX280mmX565mm)
less than 3m from Pit to Boundary
110 mm or less 150 mm
P5 PIT-ID Network Boundary/Local Network Pit (Single Lid) Service Drop conduit - Power high voltage 300 mm
450 mm
5 (700mmX450mmX650mm)
more than 3m from Pit to Boundary
low voltage 100 mm (with protection barrier)
P6 PIT-ID Distribution/Local Network Connection Pit (Dual Lid) Verge Water mains high pressure/capacity 300 mm
450 mm
6 (1360mmX555mmX650mm)
(walkways, footpaths)
local reticulation 150 mm
P8 PIT-ID Distribution/Local Network Connection Pit (Dual Lid) Road Sewer main 300 mm
600 mm
8 (1360mmX555mmX860mm)
(non-state or territory)
connection pipe 150 mm
C C
P9 PIT-ID Fibre Distribution Hub (FDH) Pit Other Telecommunications 100 mm without reduced separation agreement
Road crossing 800 mm to 1200mm (typically)
9 (2000mmX555mmX900mm)
Manhole MH-ID Distribution Network manhole General Notes
(2600mmX1240mmX1490mm)
1. NBN conduits supplied and installed by telecommunication contractor. Trenching and backfilling by
electrical contractor. Telecommunication contractor to confirm location of trench prior to installing
conduits and co-ordinate location of conduits within the trench with other services.
Pit
Pit
2. Civil contractor to install 'c' markers. 'c' markers required for all points where conduit passes under
roads or driveways.
D Min 3m Min 3m D
0-900 Truncation Max 15m Max 15m
Alignment
Back of kerb
3. Spacing between NBN conduits and other services to be as per NBN Co: installing pit and conduit
Property Boundary infrastructure- guidelines for developers manual section 4.
Pit Projected Property Boundary
Property boundary 4. NBN Co conduit must be installed on shared trench with electrical otherwise stated.
Road Min 1m
Kerb 5. Pit shall be positioned a minimum of 600mm distance from electrical pillar.
Local network pit
Primary location Min 3m Driveway ry
Min 1m o unda 6. Pit shall be installed 3m minimum from any pole and 5m from back of kerb at an intersection.
Max 15m RP B
1m
it Peg
NBN P 7. 100mm and 50mm nominal diameter conduits are detailed in as/nzs 1477:2006 table 4.2(a) for wall
Pit offset from pillar -
Service drop conduit Min 3m
600mm Lateral conduit Min 1m Energex pillar offset
thickness tabled under pn9 nominal sizes (n) 20, 50 and 100mm. All conduits shall meet the minimum
Max 15m
E Property peg
from RP Boundary Peg requirements of as/acif s008:2006 (requirements for customer cabling) and acif c524:2004 (external E
Kerb
telecommunication networks).
Min 1m
Energex pillar Pit Zero lot RP 8. All conduit bends shall be prefabricated. combinations of bends with angles of 15°, 22.5° and 30°
Projected Property Boundary
Service drop conduit should be used to changed the direction.
Property Boundary
Energex Exclusion Zone Min 3m Min 3m
9. Service drop conduit:
Local network pit Max 15m Max 15m - For single dwelling units (sdu) the service drop conduit will be 20mm (nominal id) pvc conduit.
Secondary location
Zero lot boundary confirguration - For multiple dwelling units (sdu) the service drop conduit will be 50mm (nominal id) pvc conduit.
Refer to NBN and Energex manuals for details
Pit
Pit
Pit within 6.5m of conduit 10. It is the contractors responsibility to locate existing underground services before excavating. any
change in direction
costs caused by damage to underground services will be paid by the contractor.
F F
Conduit Road Crossing 11. The contractor shall construct as per new development: deployment of the nbn co conduit and pit
0-900
Alignment network - guidelines for developers. document number: NBN-TE-CTO-194.
General road reserve confirguration Pit alignment for crossings/street corners 12. Developer's contractor to lay the conduit next to the existing Telstra but not terminate. NBN will
Refer to NBN and Energex manuals for details Refer to NBN Document number NBN-TE-CTO-194 terminate the NBN network into Telstra's network at the later stage.
13. The P20 conduits across the road are to be tested to ensure they are clear and fitted with a draw
cord.
Conduit dimensions Nominal Conduit dimensions Nominal Conduit dimensions Nominal
Size (Inside Size (Inside Size (Inside
Conduit Configuration Legend white telecommunications Diameter) white telecommunications Diameter) white telecommunications Diameter) 14. Refer to NBN Co pit and pipe network guideline section 5.2.10 for minimum depth and corner of
conduit.
G Conduits and ducts are in layer: 26.7 60.3 113.9 G
< L460 NBN Support - Underground > Capped Conduit size 15. Contractor should ensure that adequate clearances are provided between NBN assets and electrical
Conduit length 23.3 53.0 104.9
and terminology categorized into two conduit assets. If pits cannot be placed in the electrical alignment due to clearances they are to be installed
NBN pit 1.7 20 mm 3.65 50 mm 4.5 100 mm
within the comms alignment. Refer to NBN and local council construction standards to confirm
groups in the drawings as per below: PN 12 PN 12 PN 9 AS/
PIT-ID PIT-ID alignments.
P100 26.5 AS/NZS ASPN 12 NZS
1- DUCT Used with Local Network 8 8 Nominal
1477:2006
table 4.2(A) Nominal
A S/NZS
1477:2006 Nominal
1477:2006
table 4.2(A)
2-CONDUIT Used with Lead-In drops dimensions dimensions table 4.2(A) dimensions
Property boundary
(in mm.) (in mm.) (in mm.)
Attributes attached are as shown Lead-in conduit
APPROVAL ISSUE
NOT FOR TENDER OR CONSTRUCTION
STRICTLY
- - - - - THE LOCATION OF OTHER N KEY PLAN DRAWING TITLE: 1 into 5 Lot Subdivision
THIS DRAWING IS TO DO NOT CONSTRUCT AUTHORITIES SERVICES WHICH MAY
CONTRACTOR TO SUBMIT NBNCO APPROVAL SIGNATURE DATE
RECORD: 83 Butler St Tewantin QLD
H - - - - BE BUILT IN CONJUNCTION DRIVEWAYS/CROSSOVERS AFFECT THIS WORK HAVE NOT BEEN AS-BUILT DESIGNS TO AMPFLO DD H
WITH AMPFLO ELECTRICAL UNTIL ELECTRICAL WORKS OBTAINED BY THE ESTIMATOR. [email protected] Title Page and Details
CONSTRUCTOR TO OBTAIN SERVICE WD
D 29.03.23 GW APPROVAL ISSUE JB
RETICULATION DRAWINGS ARE COMPLETED INFORMATION BEFORE COMMENCING TO BE PROCESSED BY NBN AB STATE: QLD REGION: MGA56
C 08.03.23 GW REVISED TO SUIT ELECTRICAL LAYOUT JB FSA: - SAM: - ADA: -
NBNCO DISCLAIMER
DANGER FIRE ANTS ATTENTION
B 24.01.23 GW REVISED ISSUE JB
SAFETY FIRST LASER BEAM CONSTRUCTION CONTRACTOR
TO DETERMINE IF FIRE ANTS
DO NOT CHANGE OR ALTER JOB THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR THE USE OF NBNCO LIMITED (ABN
86 136 533 741) FOR USE IN MAINTAINING NBNCO FACILITIES. IT HAS NOT BEEN
ISO 9001
CERTIFIED
PROJECT No: -
A 09.01.23 GW PRELIMINARY ISSUE JB SPECIFICATIONS UNLESS FIRST CADREF No: 221869
SAFETY STARTS WITH YOU EYE PROTECTION MUST BE WORN RESTRICTIONS APPLY
CALL 13 25 33 CHECKING WITH DESIGNER
CREATED FOR ANY OTHER USE. IT SHOULD NOT BE SCALED TO LOCATE NBNCO ASSETS.
Q U A L I T Y
ABN 28 111 423 842
NO WARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE OR COMPLETE. Electrical and Telecommunications Consultants
REV DATE DRAFTER DESCRIPTION APPROVED MANAGEMENT SCALE N/A SHEET No. 1 OF 2 REV. D
07 3372 9280 [email protected]
1 2 3 4 5 6 7 8 9 10 11 12
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 1 page
Page 2
1 2 3 4 5 6 7 8 9 10 11 12
II
SDU Development Information
SW
A A
SI
N
I
II
W
Development Name:
II
II
M CRT
W
1 into 5 Lot Subdivision
II
II
SW
Developer Company:
N
II
S
W
Endeavour Foundation
W
Development Address:
2
GHOSTGU
N
83 BUTLER ST TEWANTIN QLD
S
N
W
Lot 16 N Authorised Rep:
W
RP864131 N Grant Watson
#13
N
Phone: 07 3372 9280
S
New pillar location N
W
B B
Lot 2 N E-Mail: [email protected]
PIT-004
W
RP864131 nbn Reference Number: Stage Number:
2
S
KA #85 STG- 1
W
New LICs to be capped short of P20 Design Revision:
X
N
W
existing pit. Final connection by NBN 3 D
BILL OF MATERIAL
W
W
34.6 New water meter location NO OF LOTS: 5
N
W
New pillar location PITS DUCTS
SIZE QTY SIZE QTY MTRS
W
W
New pillar location 2 0 0 P100 0
N
C C
W
KA 5 0 0 P50 0
W 6 0 5 P20 42
PIT-005 8 0
W
5 New water meter location 9 0
2 P35 W
N
W
TOTAL NUMBER OF PITS: 0
W
W 1 TOTAL NUMBER OF MANHOLES: 0
ST
TOTAL NUMBER OF CONDUITS: 5
X
TOTAL LENGTH OF CONDUITS: 42
X
N
W
BUTLER
WALL
P20
N
3
W
RET
S
D ALL DRIVEWAYS/CROSSOVERS D
SHOWN ON DRAWING ARE
WALL
P20 PROPOSED LOCATIONS
N
W
30 PROVIDED BY DEVELOPER
S
New water meter location
RET
2
W
WALL
Lot 17 S
X
KA
N
MAINTAIN CLEARANCE TO:
RP864131
RET
PROPOSED PILLARS
#22
W
PROPOSED CROSSOVERS
S
P20 PROPOSED WATER METERS
N
E 4 3 E
W
New pillar location
S
N
KA
W
S
S
SW S
P20
3
N
SW S
SW S
SW S
SW S
3
W
S
S
S S
S S
S
N
S
S S
S
F F
W
N
W
X
C
N
N
W
W
New water meter location W
N
W N
W
N
N W
W
W N
G G
W
APPROVAL ISSUE
NOT FOR TENDER OR CONSTRUCTION
STRICTLY
- - - - - THE LOCATION OF OTHER N KEY PLAN DRAWING TITLE: 1 into 5 Lot Subdivision
THIS DRAWING IS TO DO NOT CONSTRUCT AUTHORITIES SERVICES WHICH MAY
CONTRACTOR TO SUBMIT NBNCO APPROVAL SIGNATURE DATE
RECORD: 83 Butler St Tewantin QLD
H - - - - - BE BUILT IN CONJUNCTION DRIVEWAYS/CROSSOVERS AFFECT THIS WORK HAVE NOT BEEN AS-BUILT DESIGNS TO AMPFLO DD H
WITH AMPFLO ELECTRICAL UNTIL ELECTRICAL WORKS OBTAINED BY THE ESTIMATOR. [email protected] Title Page and Details
CONSTRUCTOR TO OBTAIN SERVICE WD
D 29.03.23 GW APPROVAL ISSUE JB
RETICULATION DRAWINGS ARE COMPLETED INFORMATION BEFORE COMMENCING TO BE PROCESSED BY NBN AB STATE: QLD REGION: MGA56
C 08.03.23 GW REVISED TO SUIT ELECTRICAL LAYOUT JB FSA: - SAM: - ADA: -
NBNCO DISCLAIMER
DANGER FIRE ANTS ATTENTION
B 24.01.23 GW REVISED ISSUE JB
SAFETY FIRST LASER BEAM CONSTRUCTION CONTRACTOR
TO DETERMINE IF FIRE ANTS
DO NOT CHANGE OR ALTER JOB THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR THE USE OF NBNCO LIMITED (ABN
86 136 533 741) FOR USE IN MAINTAINING NBNCO FACILITIES. IT HAS NOT BEEN
ISO 9001
CERTIFIED
PROJECT No: -
A 09.01.23 GW PRELIMINARY ISSUE JB SPECIFICATIONS UNLESS FIRST CADREF No: 221869
SAFETY STARTS WITH YOU EYE PROTECTION MUST BE WORN RESTRICTIONS APPLY
CALL 13 25 33 CHECKING WITH DESIGNER
CREATED FOR ANY OTHER USE. IT SHOULD NOT BE SCALED TO LOCATE NBNCO ASSETS.
Q U A L I T Y
ABN 28 111 423 842
NO WARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE OR COMPLETE. Electrical and Telecommunications Consultants
REV DATE DRAFTER DESCRIPTION APPROVED MANAGEMENT SCALE 1:200 SHEET No. 2 OF 2 REV. D
07 3372 9280 [email protected]
1 2 3 4 5 6 7 8 9 10 11 12