Skip to the record
Accept no substitutions.

Council archive · source document

REFERENCED DOCUMENT - Stormwater Management Plan - MCU12/0133

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
Bligh Tanner Consulting Engineers
Noosa Flexi Learning Centre Stormwater Management Plan
August 2012



Attachment A – MUSIC Modelling
The following reporting tables outline the key parameters used in the MUSIC Modelling for
this project. The table format is adopted from the Water by Design (2010) MUSIC Modelling
Guidelines V1.0. In accordance with that guideline, where recommended rainfall-runoff and
pollutant generation parameters are adopted, they aren’t reported.

Interested parties can review the model files to verify model parameters.

Table B8 Meteorological and rainfall runoff data reporting table
          Input                                  Data used in modelling
          Rainfall station                       Cooroy Composite 40059
          Time step                              6 minute
          Modelling period                       1/1/1973 – 13/12/1983 (11 years)
          Mean annual rainfall (mm/yr)           1595 mm
          Evapotranspiration (mm/yr)             1627 mm
          Rainfall runoff parameters             Predevelopment: Forested
                                                 Post development: Urban Residential (except for natural
                                                 landscaped areas which use Forested parameters)

          Pollutant export parameters            Predevelopment: Forested
                                                 Post Development: Urban Residential (except for natural
                                                 landscaped areas which use Forested parameters)


Table B9 Catchment definition reporting table
          Catchment ID                   Area (m²)              Land use          Total impervious (%)
          1 (reference to catchment      Total area of sub-     Residential,      Total impervious portion of
          plan)                          catchment              commercial,       catchment as measured
                                                                industrial etc.   off development plans
          Carpark                        370                    Residential       100%
          Buildings                                             Residential
            Knowledge                    170                    Residential       100%*
            Amenities                    70                     Residential       100%*
            Create                       318                    Residential       100%*
            Retreat                      210                    Residential       100%*
            Sound                        139                    Residential       100%*
            Allied/Support/Eat/Gather    497                    Residential       100%*
          Landscape                      3226                   Forest            0%
          Turf                           600                                      0%

          TOTAL                            5600
         *Note this is roof area, not ground level impervious area


Table B10 Rainwater tank node reporting table
          Rainwater tanks
          Catchment ID                                                  Treatment node 1
          Volume below overflow pipe (kL). If greater than 1 tank      20 kL
          specify number of tanks, volume per tank and total e.g.
          10 tanks x 5 kL = 50 kL
          Depth above overflow (m)                                     0.1
          If tanks are lumped, is depth below overflow the same as     n/a
          a single tank and overflow pipe scaled accordingly
                           2
          Surface area (m ).                                           10
          Overflow pipe diameter (mm). For lumped tanks this           150
          must be equivalent to the diameter of the overflow pipe
          of a single tank multiplied by the square root of the
          number of tanks

Used in these records

About this file

File size
1.0 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

REFERENCED DOCUMENT - Stormwater Management Plan - MCU12_0133.pdf · 1.0 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.