TEST EOUIPMENT
TESTING }VIACHINE: Avery Universal Testing Machine, Type 7110 DCJ
- Serial no. E6862
- Ma,rimum capacity: 500 kI{
- Calibration accuracyto AS 2193 - Grade "A"
TEST RESULTS
TESTDATE: 27107195
Test SAMPLE Max. Load Compressive Strength
No. No. (kr9 (MPa)
1 I 260 2.90
2 2 263 2.93
3 J 259 2.88
4 4 258 2.87
5* 5 259 2.88
6* 6 258 2.87
r Carpet tiles ( rubber backed) werr used betrveen the compression platen and ihe test samples to aid sn el'cn distribudon ofload
The load traces are shown in Appendix A
CONCLUSIONS
1. The average ma:<imum compressive load capacity for the (6) samples tested is
259.5 ld{ with a standard deviation of 1.87 kI'[, ie. 259.5 + 1.87 k]I
I The average ma:<imum compressive strength for the (6) samples tested is
2.89 MPawith a standard deviation of 0.023 MPq ie 2.89 t0.023 MPa.
Signatory
@avid Ng)