Council archive · source document
180426 1801 (Mcu 3) · MCU18/0048
Attached to the e-mail Response to information request - MCU18/0048.
Original PDF page 6, section 1. The text section number identifies this passage in the reader.
.32
.4
31
31
32
design group
D B MH
B C D E F G H building design + interior design
WD.604 WD.602
LL 32.1
3
S
5 000 1 660 5 890 1 660 3 700 8 990
34
33
0
.28
.14
.2 5
.44
.93
.14
.32
.49
34
31
34
33
34
.71
100°30'
36
35
34
OW
.950
33
3 2 4 .2 5
+T
44.056
0
.7 2
3
1
34
OW
.82
W
.42
+T
TURF
TO
.01
32
34
31
.23
.16 +
.19
.1
1 390
34
.17
OVER 12 11 10 9 8 7 6 5 4 33 2 1
32
.93
1.5m SIDE SETBACK
33
.27
WM
35
33
34
36
PLANTER FFL 34.550
2m SIDE SETBACK 2m SIDE
ENTRYSETBACK
STAIR 2
.49
OVER
0
33
.2 5
34
ia
Banks
OW
PATH
+T
.23
0
.2 5
FFL 32.520
32
34
C
OW
PLANTER
.01
+T
WD.603
4 490
33
DECK DECK NATURE
POOL OVER STRIP
LIVING 2 OVER OVER
.71
190°30'
32
15.097
OVER
ia
Banks
gate
0
31
3
.2 5
35
34
ARAKOON CRS
n us
intercom
Panda
OW
WATERCRAFT STORAGE ARRIVE
+T
.53
36
FFL 32.520 PATH
.00
2 425
FFL 32.520
.01
32
STAIRS
31
BREEZEWAY OVER
OVER
STORE
6.0M FRONT SETBACK
.67
.14
.93
4
32
31
32
STAIRS
.54
A
34
500
OVER fall P.101
15
14 fall E
.94
13
WD.605
31
.55
12 DRIVEWAY
CINEMA
34
4 085
GAMES ROOM 11 FFL 32.550 GARAGE
OVER OVER BED 10 1:26 1:7 1:4 1:8 1:40
BATH OVER
9
8
OVER
4 000
DRIVEWAY
STAIRS
.53
relocate telstra pit
7
.19
34
6
BY RPEQ
32
5 fall
4
3
2 5
500
2m SIDE SETBACK 1
6
.21
.96
32
1.5m SIDE SETBACK
30
1 600 OMP
1 600 OMP
BIKES
1 220
500
.47
401
34
shower
PLANTER
.01
.41
7
.95
35
33
33
37.498
35
NATURE
.07
280°30'
36
8 500
34
Garage side setback intrusion
to QDC requirements
STRIP
.86
8 500
30
5 000 1 660 5 890 1 660 3 700 8 990
D B
B C WD.604 D E F WD.602 G H
.91
31
MCU 3 Material change of use (3)
issue issue / amendment
26.04.18 SF. LF. AB. NB.
GARAGE LEVEL PLAN issue date
client
drawn by
SCALE 1:100 @ A3 Cori & Andrew McGuinness
project
1801 McGuinness house
EXT. FINISHES LEGEND location
7 Arakoon Cres Sunshine Beach Q 4567
GENERAL LEGEND FLOOR FINISH LEGEND WALL LEGEND AS aluminium screen. CS concrete slab. GS garage slab. SBJ silicone butt jointed glass.
TER
WIN ATH D04 denotes door number
GARAGE LEVEL PLAN
P FT1 FT2 Indicates extent of TILE RC masonry blockwork AL aluminium louvres, refer sched. DP down pipe. HWS hot water service. SP structural post, refer engineer.
SUN
m)
(7a
Lee Foster • director Scott Falconer • director
W04 denotes window number p - 0424 620 247 p - 0431 267 157
ng
ASD aluminium sliding door. DS driveway slab. HR handrail. SF structural footing, ref. eng.
si
e - [email protected] e - [email protected]
RC pool shell/off form concrete
Ri
design group
the aboda design group trust Level 2 1794 David Low Way Coolum Beach,
FFL 17.200 denotes finished floor level ABN 56 266 884 746 Q. 4573. PO box 2449 Noosa Heads Q 4567
Setting 5 pm C Indicates extent of CARPET AFD aluminium framed door. FCA fibre cement awning. LPG LPG gas bottle. TIM timber cladding. t/a aboda design group • BSA License -150580097 • www.aboda.com.au
N + RL 17.700 denotes spot level
90MM ext. timber frame
• This drawing is to be read in conjunction with engineers drawings & reports • Construction
ER H
Rising (6.30
am) AFW aluminium framed window. FC fibre cement ext. cladding. MR1 metal roof - (no refers to type). TD timber deck. to comply with all relevant SAA & NCC Codes & standard Bldg By-law 1975 & as amended •
MM AT 50 step 70MM int. timber frame
Copyright for design & drawings remain the property of the authors • Verify all dimensions on
SU N P denotes change in level TF TD Indicates extent of TIMBER. site prior to commencement of any works • These drawings are not to be used for scaling.
BA sun control battens, refer detail. FG fascia gutter. NGL natural ground line. TF timber floor.
m
SU
0p
Indicates extent of scale as shown @ A3 issue
5 .3
HATCHED AREA
HATCHED AREA
chs shs
i ng
NOT PART OF THIS denotes 'not part of structural posts - refer BAL1 balustrade-(no refers to type). FT1 floor tile (no refers to type). PF compliant pool fencing TFD timber framed door drawing See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
180426 1801 (MCU 3).pdfRelated documentApplication case desk ↗
About this file
- File size
- 5.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.