Original source · versioned page text
221363 - 2 Kestrel Cres Peregian Beach - Construction of Dwelling, Swimming Pool & Fence - Stamped - Archs
Original PDF page 9, section 1. The text section number identifies this passage in the reader.
ISSUE DATE DESCRIPTION
A 20/12/22 ISSUE FOR CLIENT SIGN OFF - CONCEPT
B 12/01/23 ISSUE FOR INFORMATION
C 06/02/23 ISSUE FOR CLIENT SIGN OFF - PLANNING
A B C D F G D
E
14/02/23
21/02/23
ISSUE FOR DEVELOPMENT APPLICATION
ISSUE FOR COORDINATION
F 06/06/23 ISSUE FOR BUILDERS TENDER
G 11/08/23 ISSUE FOR INFORMATION
H 11/08/23 ISSUE FOR CONTRACT
I 16/08/23 ISSUE FOR CONTRACT
J 21/08/23 ISSUE FOR PRICING
K 20/09/23 ISSUE FOR BUILDING APPROVAL
Y
AR
UND
O
EB
S IT
ROOF LEGEND
REFER TO ENERGY EFFICIENCY REPORT FOR COMPIANCE
RF01
COLORBOND CUSTOM ORB ULTRA ROOF SHEETING TO BE IN ACCORDANCE
WITH MANUFACTURERS SPECIFICATIONS ON TS44 ROOF BATTENS @ 900
CENTRES
SIT
EB
OUN
DAR
Y
1 2
A3000 A3000
9700 13248
DP DP
GUTTER
OVERHANG
800
1 LINE OF BUILDING BELOW
LINE OF BUILDING BELOW
13.00°
1100 RI
DG
DG
E
E RI
FIXED
800
550
SKYLIGHT TO
SHOWER
OVERHANG
GUTTER
1
LINE OF HOUSE BELOW
A3001
LINE OF BUILDING BELOW
800
DP DP
IN CEILING GUTTER
OVERHANG
13.00°
700
SPACE
PROPOSED A/C
800
UNIT
2 BLADE WALL -
RL. 30.970 RIDGE
POWDERCOATED LINE OF FIRST FLOOR BELOW
FLASHING OVER DP
TO MATCH ROOF
3
13.00° 13.00°
14434
EY
LL
VA
RIDGE
2
GE
RID
A3001
LINE OF BUILDING BELOW
SITE BOUNDARY
800
CLIENT:
LINE OF BUILDING BELOW
PROPOSED A/C
UNIT
ANDREW + ANDREA MACLAREN
1400
RIDGE
9700
9700
13
WIND DRIVEN ROOF .00
VENTILATION °
LL
FA
IN CEILING
SPACE
PROJECT:
FALL
CNR KESTREL CRES & LORILET ST
RE
1275
TT
E
GU
DG
RI
RID
WIND DRIVEN ROOF
GE
VENTILATION
DP
13.00°
DP
688
FIXED SKYLIGHT
TO KITCHEN
ARCHITECT:
M. 0475 030 630
Y
W. honghenwood.com
AR
LL
ND
FA
E. [email protected]
OU
1
EB
A3002 ABN No. 12822847278
S IT
DRAWING TITLE:
FALL FALL GUTTER
DP SPITTER DP
460
FIXED SKYLIGHT
4 TO SHOWER ROOF PLAN
5.00° FALL
T.O.W 28.305
A3002 870
GARAGE WALL
FALL
PARAPET TO
GUTTER DP
NOTES: NORTH:
1. Use only figured dimensions, do not scale drawings.
2. All discrepancies and omissions to be referred to Hong Henwood
H
FALL GUTTER Design prior to construction.
RT
3. Check all dimensions, Building Code of Australia, relevant codes
NO
DP
and council approvals.
SITE BOUNDARY 4. This drawing is not for construction.
Copyright remains the property of Hong Henwood. Reproduction of the
whole or part of this document constitutes an infringement of copyright.
5. Nominated Architect: Karen Leech QLD 5795
20/09/2023 4:37:06 PM
200 6485 7172 SCALE: DATE:
ROOF PLAN As indicated @ A1 11/08/23
1 15395 DRAWN BY: CHECKED BY: PROJECT NO: DRAWING NO: ISSUE:
Scale: 1 : 50
H KL HH 2216
A1102
CAD FILE:
K
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.