Original source · versioned page text
221363 - 2 Kestrel Cres Peregian Beach - Construction of Dwelling, Swimming Pool & Fence - Stamped - Archs
Original PDF page 13, section 1. The text section number identifies this passage in the reader.
ISSUE DATE DESCRIPTION
A 12/01/23 ISSUE FOR INFORMATION
B 21/02/23 ISSUE FOR COORDINATION
C 06/06/23 ISSUE FOR BUILDERS TENDER
D 20/09/23 ISSUE FOR BUILDING APPROVAL
A B C D F G
CEILING LEGEND
SQUARESET AQUACHEK PAINT FINISH
INTERNAL PLASTERBOARD CELING
MOISTURE RESISTANT PLASTERBOARD TO WET AREAS
INTERNAL PLASTERBOARD BULKHEAD @ 2400
UNDERSIDE OF SLAB
RENDER AND PAINT FINISH TO SLAB EDGE
LIGHTING AND ELECTRICAL LEGEND
WALL LIGHT
DOWNLIGHT
LIGHT SWITCH
S SMOKE DETECTOR
EXHAUST FAN
800
UNDERSIDE OF SOFFITT SENSOR LIGHT
SQUARESET AQUACHEK PAINT FINISH
1 1 *REFER TO FIXTURES SCHEDULE BY HONG HENWOOD DESIGN FOR LIGHTING
FIXTURE SELECTIONS
CEILING MOUNTED CURTAIN TRACKS
800
ENSUITE
FCL 2700
NOTES
ABOVE RL
P ALL LIGHTING LOCATIONS, SWITCHES AND CIRCUITS TO BE COORDINATED AND
CEILING MOUNTED
AIR CON GRILLE CONFIRMED ON SITE BETWEEN CLIENT, BUILDER, DESIGNER AND ELECTRICAL
MASTER BEDROOM CONTRACTOR
CEILING MOUNTED CURTAIN TRACKS
ALL INTERNAL LIGHTING TO HAVE ELECTRONIC DIMMABLE SWITCHES
LIGHT FITTINGS TO BE SOURCED BY OWNER WITH BUILDER ALLOW FOR INSTALL
T
GH
Y LI
WALL MOUNTED
AIR CON GRILLE
SK ALL EXHAUSTS TO EXTRACT EXTERNALLY.
SMOKE ALARMS: INTERCONNECTED PHOTOELECTRIC SMOKE ALARMS TO BE IN
ACCORDANCE WITH PART 3.7.2 OF THE BCA AND AS 3786 TO BE HARD WIRED TO
CONSUMER SUPPLY WITH BATTERY BACKUP. POSITINING TO COMPLY WITH
FCL 2700 REGULATIONS TO ELECTRICAL SPEC.
ABOVE RL
ROBE
FCL 2700
ABOVE RL
A
P
0
60
PROPOSED A/C P
0x
UNDERSIDE OF SOFFITT
800
60
UNIT
SQUARESET AQUACHEK PAINT FINISH
2 2
185
SD
DINING
3 3
3196
UPSTAIRS TERRACE
UNDERSIDE OF SOTFIT - SAUARESET AQUACHEK - PAINT FINISH
P P
2 WAY
FCL 2700
ABOVE RL
P
2 WAY
CEILING MOUNTED
AIR CON GRILLE
CEILING MOUNTED
AIR CON GRILLE
CLIENT:
4 SD 4
PROPOSED A/C ANDREW + ANDREA MACLAREN
UNIT
840
SQUARESET AQUACHEK PAINT FINISH
1050
UNDERSIDE OF SOFFITT
1500
PROJECT:
GARAGE LIVING
LED BELOW ON SENSOR CNR KESTREL CRES & LORILET ST
620
WHIRLYBIRD
ARCHITECT:
LED TO UNDERSIDE OF SHELVES
KITCHEN
PANTRY
A
0
60
P M. 0475 030 630
0x
60
W. honghenwood.com
FCL 2700
ABOVE RL
E. [email protected]
CEILING MOUNTED
ABN No. 12822847278
AIR CON GRILLE
EXHAUST
DRAWING TITLE:
REFLECTED CEILING PLAN - FIRST
FLOOR
5 5
NOTES: NORTH:
1. Use only figured dimensions, do not scale drawings.
6 6 2. All discrepancies and omissions to be referred to Hong Henwood
H
Design prior to construction.
RT
3. Check all dimensions, Building Code of Australia, relevant codes
NO
and council approvals.
4. This drawing is not for construction.
Copyright remains the property of Hong Henwood. Reproduction of the
whole or part of this document constitutes an infringement of copyright.
5. Nominated Architect: Karen Leech QLD 5795
20/09/2023 4:37:27 PM
SCALE: DATE:
1 : 50 @ A1 11/08/23
REFLECTED CEILING PLAN - FIRST FLOOR DRAWN BY: CHECKED BY: PROJECT NO: DRAWING NO: ISSUE:
1 H KL HH 2216
Scale: 1 : 50
A B C D F G CAD FILE: A1201 D