221363 - 2 Kestrel Cres Peregian Beach - Construction of Dwelling, Swimming Pool & Fence - Stamped - Archs
Original PDF page 16, section 1. The text section number identifies this passage in the reader.
ISSUE DATE DESCRIPTION
A 06/06/23 ISSUE FOR BUILDERS TENDER
B 11/08/23 ISSUE FOR INFORMATION
C 11/08/23 ISSUE FOR CONTRACT
D 16/08/23 ISSUE FOR CONTRACT
E 20/09/23 ISSUE FOR BUILDING APPROVAL
SITE BOUNDARY
SETBACK
SETBACK
SITE BOUNDARY
OUND LEVEL
NATURAL GR
8000 ABOVE
2000
LEVEL
RAL GROUND
7500 ABOVE NATU
FEATURE BLADE WALL WITH
SL 201 PAINT FINISH
600
Roof Level
GLAZING HEAD HEIGHT RL.29.570
LIGHTWEIGHT CLADDING TO UPPER
LEVEL PAINT FINISH
W W203
FIXED GLASS RL. 28.305
2700
2100
W W202
PT05
600
LIGHTWEIGHT CLADDING RENDERED BASE TO BUILT TO BOUNDARY WALL (TO
TO UPPER LEVEL PAINT GARAGE. PAINT FINISH COMPLY WITH QBD, MAX MEAN
FINISH HEIGHT OF 3.5M + 9M LENGTH
900 T.O.W 27.105
GLAZING SILL HEIGHT
600 300
Level 1
PT05 AP01
RL.26.870
PIVOT FRONT DOOR FIXED
2400
550
WITH TIMBER LOOK GLASS D 01
RENDER + PAINT GF
1675
ALUMINIUM BATTEN
PROFILE OVER
MB HWC
W W101 SECTIONAL GARAGE DOOR
PT05
OUND LEVEL
NATURAL GR Entry
2000 ABOVE
3000
BINS / STORE
RENDER & PAINT FINISH RL.25.370
2400
2400
PT05
CONSTRUCTION OF DRIVEWAY AND CROSSOVER TO
BE IN ACCORDANCE WITH NOOSA STANDARD
DRAWINGS (RS049/50) - FINAL SHAPE/SIZE TBC ON
SITE WITH BUILDER + CLIENT
Ground Floor
CRUSHED GRANITE RL.23.870
OUND LE VEL
NATURAL GR PLANTER
NEW LAWN
SOUTH WEST - BEHIND WALL
1 Scale: 1 : 50
CLIENT:
Roof Level ANDREW + ANDREA MACLAREN
RL.29.570
PROJECT:
CNR KESTREL CRES & LORILET ST
Level 1
RL.26.870 ARCHITECT:
WITHI N SETBACKS)
IT (HARDSCAPE
2.0m HEIGHT LIM M. 0475 030 630
ST03 W. honghenwood.com
Entry
E. [email protected]
RL.25.370
ABN No. 12822847278
DRAWING TITLE:
Ground Floor
RL.23.870 WEST ELEVATIONS
FEATURE STONE CLAD ENTRY ALUMINIUM BATTEN
BLOCK WALL PEDESTRIAN GATE
NOTES: NORTH:
1. Use only figured dimensions, do not scale drawings.
SOUTH WEST - FROM STREET WITH FENCING 2. All discrepancies and omissions to be referred to Hong Henwood
H
Design prior to construction.
RT
2 3. Check all dimensions, Building Code of Australia, relevant codes
NO
Scale: 1 : 50 and council approvals.
4. This drawing is not for construction.
Copyright remains the property of Hong Henwood. Reproduction of the
whole or part of this document constitutes an infringement of copyright.
5. Nominated Architect: Karen Leech QLD 5795
20/09/2023 4:37:46 PM
SCALE: DATE:
1 : 50 @ A1 11/08/23
DRAWN BY: CHECKED BY: PROJECT NO: DRAWING NO: ISSUE:
KL HH 2216
CAD FILE: A2000 E
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.