Original source · versioned page text
221363 - 2 Kestrel Cres Peregian Beach - Construction of Dwelling, Swimming Pool & Fence - Stamped - Archs
Original PDF page 33, section 1. The text section number identifies this passage in the reader.
ISSUE DATE DESCRIPTION
A 06/06/23 ISSUE FOR BUILDERS TENDER
B 16/08/23 ISSUE FOR CONTRACT
WINDOW + LOUVRE SCHEDULE C 20/09/23 ISSUE FOR BUILDING APPROVAL
EAST ELEVATION
GENERAL WINDOW NOTES
WINDOW AND DOOR RESTRICTIONS TO BCA D2.24 TO BE CERTIFIED BY WINDOW
4825 CONTRACTOR
ALL EXTERNAL WINDOWS AND DOORS DRAWN AS VIEWED FROM EXTERIOR
820 500 900 EQ EQ EQ EQ
900 CONFIRM ALL DIMENSIONS ON SITE PRIOR TO MANUFACTURE
WINDOW SUB-CONTRACTOR TO PROVIDE FULL SET OF SHOP DRAWINGS FOR
COMMENT DISPLAYING HEAD, SILL & JAMB DETAIL PRIOR TO MANUFACTURE
GLAZING TO COMPLY WITH AUSTRALIAN STANDARDS, NCC (BCA) AND ENERGEY
EFFICIENCY REPORT
W E104 GLASS SAMPLES TO BE APPROVED PRIOR TO ORDER. SUBCONTRACTOR TO
2400
2400
2400
2400
W E101 W E102 W E103 PROVIDE CERTIFICATION COMPLIANCE WITH ENERGY EFFICIENCY REPORT UPON
COMPLETION
ALUMINIUM FRAME SECTION TO BE APPROVED BY SUPERINTENDENT. ALUMINIUM
DOORS TO HAVE RECESSED FINGER PULL
HARDWARE TO ALUMINIUM JOINERY TO BE AWS ICON SERIES OR APPROVED
FIXED SLIDING SLIDING SLIDING EQUIVALENT
Ground Floor Ground Floor Ground Floor Ground Floor
30
30
30
30
RL.23.870 RL.23.870 RL.23.870 RL.23.870 SCREENS TO BE MOUNTED EXTERNALLY TO COMPLY WITH BAL19 TO
CERTIFICATION REQUIREMENTS
HINGED DOORS - ALLOW 3 STAINLESS STEEL BUTT HINGES PER DOOR. 316
STAINLESS FOR EXTERNAL.
ALL FRAMELESS GLASS PANELS TO BE TEMPLATED ON SITE FOR FABRICATION
POWDER COATED ALUMINUM FRAME - COLOUR (TBA)
SAMPLES OF STACKER DOOR TRACKS TO BE PROVIDED FOR APPROVAL
WINDOW NUMBER W-E101 WINDOW NUMBER W-E102 WINDOW NUMBER W-E103 WINDOW NUMBER W-E104
ELEVATION EAST ELEVATION EAST ELEVATION EAST ELEVATION EAST
LEVEL GROUND LEVEL LEVEL LEVEL 1 LEVEL GROUND LEVEL LEVEL GROUND LEVEL
ROOM NAME LAUNDRY ROOM NAME HALLWAY ROOM NAME HALLWAY ROOM NAME MEDIA / BED 4
ITEM TYPE DOOR / LOUVRE ITEM TYPE LOUVRE ITEM TYPE DOOR ITEM TYPE SLIDING STACKER DOOR
FRAME TYPE FRAME TYPE FRAME TYPE FRAME TYPE
FRAME FINISH FRAME FINISH FRAME FINISH FRAME FINISH
GLASS TYPE GLASS TYPE CLEAR GLASS TYPE GLASS TYPE
LOUVRE TYPE LOUVRE TYPE LOUVRE TYPE LOUVRE TYPE
SILL HEIGHT REBATED INTO SLAB SILL HEIGHT REBATED INTO SLAB SILL HEIGHT REBATED INTO SLAB SILL HEIGHT REBATED INTO SLAB
HARDWARE HARDWARE HARDWARE HARDWARE
FIRE REQUIREMENTS FIRE REQUIREMENTS FIRE REQUIREMENTS FIRE REQUIREMENTS
ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES
EAST ELEVATION
2080 1685 1245 3775
900
CONFIRM MEASURE ON SITE
CLIENT:
Roof Level Roof Level Roof Level Roof Level Roof Level
RL.29.570 RL.29.570 RL.29.570 RL.29.570 RL.29.570
ANDREW + ANDREA MACLAREN
FRAMLESS WINDOW CORNER
EQ
2700
2700
2700
2700
2700
W E201 W E202 W E203 W E204
PROJECT:
W E205
CNR KESTREL CRES & LORILET ST
EQ
Level 1 FIXED Level 1 FIXED Level 1 Level 1 Level 1
30
30
30
30
30
RL.26.870 RL.26.870 RL.26.870 RL.26.870 RL.26.870
ARCHITECT:
M. 0475 030 630
W. honghenwood.com
E. [email protected]
ABN No. 12822847278
WINDOW NUMBER W-E201 WINDOW NUMBER W-E202 WINDOW NUMBER W-E203 WINDOW NUMBER W-E204 WINDOW NUMBER W-E205
ELEVATION EAST ELEVATION EAST ELEVATION EAST ELEVATION EAST ELEVATION EAST DRAWING TITLE:
LEVEL FIRST LEVEL LEVEL FIRST LEVEL LEVEL FIRST LEVEL LEVEL FIRST LEVEL LEVEL FIRST LEVEL
WINDOW SCHEDULE
ROOM NAME LIVING ROOM NAME DINNG ROOM NAME TERRACE ROOM NAME TERRACE ROOM NAME MASTER BEDROOM
ITEM TYPE LOUVRE ITEM TYPE FIXED GLASS WITH FRAMLESS CORNER ITEM TYPE FIXED ITEM TYPE DOOR ITEM TYPE SASH WINDOW
FRAME TYPE FRAME TYPE FRAME TYPE FRAME TYPE FRAME TYPE
NOTES: NORTH:
FRAME FINISH FRAME FINISH FRAME FINISH FRAME FINISH FRAME FINISH 1. Use only figured dimensions, do not scale drawings.
2. All discrepancies and omissions to be referred to Hong Henwood
H
Design prior to construction.
RT
GLASS TYPE CLEAR GLASS TYPE CLEAR GLASS TYPE GLASS TYPE GLASS TYPE
3. Check all dimensions, Building Code of Australia, relevant codes
NO
and council approvals.
LOUVRE TYPE LOUVRE TYPE LOUVRE TYPE LOUVRE TYPE LOUVRE TYPE 4. This drawing is not for construction.
Copyright remains the property of Hong Henwood. Reproduction of the
whole or part of this document constitutes an infringement of copyright.
SILL HEIGHT REBATED INTO SLAB SILL HEIGHT REBATED INTO SLAB SILL HEIGHT REBATED INTO SLAB SILL HEIGHT REBATED INTO SLAB SILL HEIGHT REBATED INTO SLAB 5. Nominated Architect: Karen Leech QLD 5795
20/09/2023 4:40:13 PM
HARDWARE HARDWARE HARDWARE HARDWARE HARDWARE
SCALE: DATE:
FIRE REQUIREMENTS FIRE REQUIREMENTS FIRE REQUIREMENTS FIRE REQUIREMENTS FIRE REQUIREMENTS TO COMPLY WITH BAL RATING As indicated @ A1 11/08/23
DRAWN BY: CHECKED BY: PROJECT NO: DRAWING NO: ISSUE:
ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES
KL HH 2216
CAD FILE: A5101 C
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.