Original source · versioned page text
221363 - 2 Kestrel Cres Peregian Beach - Construction of Dwelling, Swimming Pool & Fence - Stamped - Archs
Original PDF page 35, section 1. The text section number identifies this passage in the reader.
ISSUE DATE DESCRIPTION
A 06/06/23 ISSUE FOR BUILDERS TENDER
B 20/09/23 ISSUE FOR BUILDING APPROVAL
FN01
FN0
1
PF02 (1200AFFL)
FN01
FN
01
AP02 (1000H)
PF02 (1200
(1000H)
HR02
BAL02 (1050 AFFL)
AP02
AFFL)
HR01 PF01
(1200H)
BAL01 (1050 AFFL)
AP01
AP02
BAL01
HR01 HR01
SCN01
AP02 (VARYING
HEIGHTS)
FIRST FLOOR PLAN
GROUND FLOOR PLAN 2 Scale: 1 : 200
1 Scale: 1 : 200
BALUSTRADES HANDRAILS SCREENS POOL FENCING
CLIENT:
2 ANDREW + ANDREA MACLAREN
G
PROJECT:
CNR KESTREL CRES & LORILET ST
12mm x 40mm STEEL 40 50
FLATBAR HANDRAIL.
40 50 POWDERCOAT FINISH
40
12
40
40
FRAMELESS TOUGHENED ARCHITECT:
1200 AFFL
1200 AFFL
SQUARE SET SAFETY GLASS
PLASTERED 40 x 40mm 12mm DIA. STEEL FRAMELESS TOUGHENED
FULL HEIGHT 30 x 30 REFER TO SCHEDULE BALUSTRADE TO
BATTENS WITH
1050 ABOVE FFL
BALUTRADE CUSTOM OAK ROUND BRACKET MANUFACTURER'S REQ'S SAFETY GLASS
HARDWOOD BATTENS TO
1050 ABOVE FFL
40mm SPACING
1050 AFFL
TIMBER HANDRAIL AND AUSTRALIAN BALUSTRADE TO
INTERIOR DESIGNER VARYING HEIGHTS
STANDARDS MANUFACTURER'S REQ'S M. 0475 030 630
1050 AFFL
SELECTION
12mm STEEL ROD WITH WELDED AND AUSTRALIAN
CONNECTION TO BAR UPRIGHT STANDARDS W. honghenwood.com
FINISH TO INTERIOR DESIGNERS
SELECTION TO MANUFACTUERES
E. [email protected]
RECESSED Ground Floor Ground Floor
60 120
SKIRTING SPECIFICATION. FACTORY APPLIED ABN No. 12822847278
1550
RL.23.870 RL.23.870
25mm BATTEN TO
50 50
SLAB EDGE Level 1 Level 1
FFL FFL
BALUSTRADE SPIGOT SIMILAR /
120
RL.26.870 RL.26.870
EQUIVALENT TO AXIOM DRAWING TITLE:
FIXED TO SLAB SEASCAPE SD16-02 FIXED TO COUNTER SUNK STAINLESS
EDGE SLAB [CONCEALED FIXING]. STEEL PATCH FITTING TO
SCREENS, BALUSTRADES AND
600
PROVIDE CERTIFIED SLAB EDGE. SPACING TO
SQUARE SET
CEILING ACRCYLIC RENDER
BALUSTRADE SYSTEM.
ENGINEER TO CERTIFY
MANUFACTURERS
REQUIREMENTS. PROVIDE
HANDRAILS
TOP SLAB EDGE
CONNECTION TO STRUCTURE CERTIFIED BALUSTRADE
SYSTEM. ENGINEER TO
CERTIFY CONNECTION TO
NOTES: NORTH:
STRUCTURE
1. Use only figured dimensions, do not scale drawings.
2. All discrepancies and omissions to be referred to Hong Henwood
H
Design prior to construction.
RT
3. Check all dimensions, Building Code of Australia, relevant codes
NO
and council approvals.
4. This drawing is not for construction.
Copyright remains the property of Hong Henwood. Reproduction of the
BAL01 BAL02 HR01 HR02 SCN01 AP02 PF01 PF02 whole or part of this document constitutes an infringement of copyright.
5. Nominated Architect: Karen Leech QLD 5795
20/09/2023 4:40:43 PM
SCALE: DATE:
As indicated @ A1 11/08/23
DRAWN BY: CHECKED BY: PROJECT NO: DRAWING NO: ISSUE:
KL HH 2216
CAD FILE: A5106 B
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.