Original source · versioned page text
200437-C-Drawings
Original PDF page 1, section 1. The text section number identifies this passage in the reader.
33 TEWANTIN ROAD, COOROY, QLD, 4563 MULTIPLE DWELLINGS DEVELOPMENT OPERATIONAL WORKS - CIVIL COUNCIL MCU PERMIT No. MCU20/0074 GENERAL NOTES: 1. DRAWINGS TO BE READ IN CONJUNCTION WITH ALL RELEVANT DOCUMENTATION, LOCAL AUTHORITY DRAWING INDEX SPECIFICATIONS (OR ARCOS GROUP SPECIFICATIONS IF SUPPLIED). ANY POINT OF CONFLICT I TO BE IDENTIFIED BY THE CONTRACTOR AN WILL BE RESOLVED BY THE SUPERINTENDENT. DRAWING No. DRAWING TITLE 2. THE DEVELOPER IS TO NOMINATE THE SUPERINTENDENT FOR THE WORKS AND NOTIFY ALL RELEVANT 200437-C-00011 CIVIL - LOCALITY PLAN & DRAWING INDEX PARTIES PRIOR TO COMMENCEMENT OF CONSTRUCTION. 200437-C-00012 CIVIL - SITE LAYOUT & DRIVEWAY SECTION 3. DIMENSIONS IN METRES (U.N.O). DO NOT SCALE FROM DRAWINGS. USE PRINTED DIMENSIONS ONLY AND IF IN DOUBT ASK SUPERINTENDENT FOR CLARIFICATION. 200437-C-00013 CIVIL - ROADWORKS & DRAINAGE LAYOUT 4. ALL WORKS TO BE CONSTRUCTED IN ACCORDANCE WITH LOCAL COUNCIL APPROVAL CONDITIONS, 200437-C-00014 CIVIL - EROSION AND SEDIMENT CONTROL LAYOUT DEVELOPMENT GUIDELINES, ASSOCIATED STANDARD DRAWINGS AND SPECIFICATIONS U.N.O. AD SITE LOCATION 200437-C-00015 CIVIL - EROSION AND SEDIMENT CONTROL NOTES AND DETAILS 5. EXISTING SERVICES HAVE BEN PLOTTED FROM SUPPLIED DATA AND AS SUCH THEIR ACCURACY CANNOT BE RO GUARANTEED. IT IS THE CONTRACTORS RESPONSIBILITY TO ESTABLISH THE LOCATION AND LEVEL OF ALL N EXITING SERVICES PRIOR TO COMMENCEMENT OF ANY WORK. DISCREPANCIES HALL BE REPORTED TO THE TI SUPERINTENDENT. 200437-C-00101 SEWER RETICULATION - LOCALITY AND NOTES AN REET 6. ON COMPLETION OF SERVICES INSTALLATION, ALL AREAS SHALL BE RESTORED TO ORIGINAL LEVEL, 200437-C-00102 SEWER RETICULATION - LAYOUT AND DETAILS W E INCLUDING KERBS, FOOTPATHS, CONCRETE AREAS, GRAVEL AREAS, GRASSED AREAS AND ROAD TE N LA PAVEMENTS. KAURIF ST 200437-C-00201 E 7. THE CONTRACTOR HAL BE RESPONSIBLE FOR REPAIR OF ANY DAMAGE TO COUNCILS INFRASTRUCTURE. WATER RETICULATION - LOCALITY AND NOTES IN EET SUCH REPAIR OR REINSTATEMENT TO BE CARRIED OUT IMMEDIATELY TO THE SATISFACTION OF LOCAL V COUNCIL. 200437-C-00202 WATER RETICULATION - LAYOUT AND DETAILS LI O MIVA STR 8. THE CONTRACTOR SHALL PROVIDE ALL MANAGEMENT PLANS, INCLUDING TRAFFIC MANAGEMENT PLAN, ENVIRONMENTAL MANAGEMENT PLAN AND WORK PLACE HEALTH AND SAFETY PLAN FOR REVIEW AND APPROVAL OF PRINCIPAL AND SUPERINTENDENT, PRIOR TO CONSTRUCTION. 9. THE CONTRACTOR IS TO UNDERTAKE ALL WORKS IN ACCORDANCE WITH ALL WORKPLACE HEALTH AND SAFETY REQUIREMENTS. 10. WHERE ANY EXCAVATION OR CONSTRUCTION WORKS ARE IN CLOSE PROXIMITY TO NEIGHBOURING LOT BOUNDARIES OR INFRASTRUCTURE, THE CONTRACTOR IS TO ALLOW IN SCOPE OF WORKS TO PROVIDE ALL MEASURES NECESSARY TO ENSURE THE INTEGRITY OF EXISTING BOUNDARIES AND INFRASTRUCTURE. THIS MAY INCLUDE THE USE OF LOW VIBRATION EQUIPMENT, TRENCH SHORING ETC AS REQUIRED. 11. THE CONTRACTOR SHALL NOTIFY ARCOS GROUP PRIOR TO COMMENCING WORKS AND RECEIVE WRITTEN IMAGE (NEARMAP) CONFIRMATION THAT THE WORKS CAN COMMENCE. LOCALITY PLAN 12. CONTRACTOR SHALL PROVIDE AS CONSTRCUTED DRAWINGS FOR ALL CONSTRUCTED WORKS IN N.T.S ACCORDANCE WITH LOCAL COUNCIL REQUIREMENTS ULSS OTHERWISE ADVISED BY ARCOS GROUP. 13. THE FOLLOWING HOLD POINT INSPECTIONS WILL BE REQUIRED; Filename: C:\USERS\GRANT\ARCOSGROUP.COM.AU\BILLY BLAKE - ARCOS\6.0 PROJECTS\200437 - COOROY, PROPOSED DUAL OCCUPANCY - 33 TEWANTIN ROAD\4.0 CAD\DRAWINGS\200437-C-00011.DWG · CONSTRUCTION PRE-START MEETING · SET OUT · DEMOLITION · SUBGRADE PROOF-ROLLS · PRE-SEAL PROOF-ROLLS SURVEY DATA DEMOLITION · CONCRETE PRE-POURS SURVEYED BY 'CADCON INTERNATIONAL DEMOLISH OR RELOCATE OFF SITE ALL EXISTING BUILDINGS PTY LTD' DATED 30/09/2020. PLAN AND/OR STRUCTURES ON SITE AND DISCONNECT AND · FINAL INSPECTION REFERENCE 208522-01-01 WHERE REQUIRED CAP ALL ASSOCIATED SERVICES IN 14. THE CONSTRUCTION PRE-START MEETING IS AN OPPORTUNITY FOR ALL PARTIES TO DISCUSS CRITICAL ACCORDANCE WITH A PLUMBING AND DRAINAGE ISSUES, SUCH AS: APPLICATION PRIOR TO DEMOLITION COMMENCING. ● KEY OBJECTIVES OF THE EROSION AND SEDIMENT CONTROL PLAN; ● REQUIRED WATER QUALITY OBJECTIVES; BUILDING DESIGN WARNING CLEARING ● PERFORMANCE MONITORING AND INSPECTION PROCEDURES; BUILDING AND LANDSCAPE DESIGN BY BEWARE OF UNDERGROUND SERVICES 'ABODE SOLUTIONS' REV B. THE CONTRACTOR SHALL REMOVE ALL EXISTING ● IDENTIFICATION OF THE RESPONSIBLE SITE OFFICERS; VEGETATION WITHIN THE SITE IN ACCORDANCE WITH THE APPROVED TREE RETENTION PLAN IF SPECIFIED. POSITION OF EXISTING UNDERGROUND SERVICES SHOWN ● IDENTIFICATION OF CRITICAL ENVIRONMENTAL CONCERNS; IS APPROXIMATE ONLY. EXACT POSITION SHALL BE · ● REPORTING PROCEDURES FOR NON-COMPLIANCE ACTIVITIES AND EVENTS. PROVEN ON SITE BY THE CONTRACTOR PRIOR TO COMMENCEMENT OF CONSTRUCTION SETTING OUT DESIGN FINISHED SURFACE LEVELS OF STRUCTURES ARE FOR THE CONTRACTOR'S GUIDANCE ONLY. ACTUAL FINISHED LEVELS SITE DATA SHALL BE SET OUT AS DIRECTED ON-SITE IN KEEPING WITH THE LOCATION OF SERVICES REQUIREMENTS AND SPECIFICATIONS OF THE LOCAL AUTHORITY PRIOR TO COMMENCEMENT OF NEW WORK THE RPD AND ACTUAL FINISHED GROUND LEVELS. CONTRACTOR SHALL CONFIRM LOCATIONS, LEVELS AND LOT 107 ON C 5604 DETAILS OF EXISTING CONNECTION POINTS AND SERVICE CROSSINGS BY POT HOLING. IF A VARIATION OCCURS PARISH: TEWANTIN CONTACT THE ENGINEER PRIOR TO CONSTRUCTION. COUNTY: WARD SITE AREA Last Plotted: 2020-12-18 PROTECTION OF SERVICES THE CONTRACTOR SHALL CONTACT THE RELEVANT 1012m2 TOTAL AUTHORITIES AND ARRANGE FOR RELOCATION AND / OR PROTECTION OF EXISTING SERVICES AS REQUIRED TO SUIT LOCAL AUTHORITY Last saved by: GRANT(2020-12-18) SURROUNDING NEW WORK, CONSTRUCTION LOADINGS AND NOOSA SHIRE COUNCIL TO SUIT FINAL FINISHED SURFACE LEVELS AND GRADES. ZONE CLASSIFICATION MEDIUM DENSITY RESIDENTIAL North Point Scale Horiz. Datum Client Consultant Project Drawing LOCAL Drawn GM Drawing No. Rev No. MIDSON CONSTRUCTIONS 33 TEWANTIN ROAD CIVIL 0 25 50 Vert. Datum (QLD) PTY LTD COOROY, QLD, 4563 Design GM LOCALITY, DRAWING INDEX AND A1 1:1000 m AHD MULTIPLE DWELLINGS DEVELOPMENT Check LS GENERAL NOTES 200437-C-00011 A A FOR OPW APPROVAL 17.12.20 LS RL Datum CIVIL | STRUCTURAL | GEOTECHNICAL OPW APPLICATION Approved Signed P1 PRELIMINARY 16.11.20 LS OPM 24963 COPYRIGHT © All rights reserved. Sheet Rev Revision Description Date Approved RL 125.924 This work is copyright and cannot be reproduced or copied in any form without the prior consent SUNSHINE COAST | BRISBANE | GOLD COAST www.arcosgroup.com.au | ABN 51 640 311 842 Date 17.12.20 L.SWANN RPEQ 21223 Status NOT FOR CONSTRUCTION Size A1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original (200437-C-Drawings.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.