200437-C-Drawings
Original PDF page 9, section 1. The text section number identifies this passage in the reader.
STATE ROAD ASSET:
CONTRACTOR TO ARRANGE NECESSARY
EXISTING APPROVALS WITH TRANSPORT AND MAIN
Carport TELSTRA PIT
ROADS FOR ROAD CROSSING WORKS.
EXISTING POWER POLE
EXISTING ROAD
CROWN
PROVIDE UNDERBORE ACROSS
TEWANTIN ROAD IN ACCORDANCE WITH
STD DRG SEQ-WAT-1108-1 & 1108-2.
EXISTING CROSSING LOCATION TBC ON
SITE PRIOR TO WORKS.
OLIVINE LANE
PROPOSED UNIT 1
UTILISE EXISTING WATER SERVICE .05
22
1
LOCATION. REPLACE BOX/ METER AND
PROVIDE SUB-METERING ARRANGEMENT IN UTILISE EXISTING WATER CONNECTION
TEWANTIN ROAD
ACCORDANCE WITH UNITYWATER LOCATION FOR SUBJECT LOT. PROVIDE
REQUIREMENTS WATER PROPERTY SERVICE AND
METER POINT POSITION IN
EXISTING ACCORDANCE WITH STD DRG
DWELLING SEQ-WAT-1108-2
GARAGE FFL 115.500
GROUND FLOOR FFL 116.7
PROPOSED UNIT 2
EXISTING DN100 AC WATER MAIN (ASSET ID 2040454).
ALIGNMENT FOLLOWS BACK OF EXISTING KERB
EXISTING FIRE HYDRANT
LOCATED AT BACK OF KERB
Dilapidated Shed
LIVE WATER WORKS SCHEDULE
DESCRIPTION DIA.
No.
(SEE NOTES FOR AGENCY) SEWER
Filename: C:\USERS\GRANT\ARCOSGROUP.COM.AU\BILLY BLAKE - ARCOS\6.0 PROJECTS\200437 - COOROY, PROPOSED DUAL OCCUPANCY - 33 TEWANTIN ROAD\4.0 CAD\DRAWINGS\200437-C-00202.DWG
AGENCY TO CONNECT TO EXISTING WATER MAIN AT DEVELOPERS EXPENSE
1 (A) DN150
FOLLOWING SUCCESSFUL "ON MAINTENANCE" INSPECTION.
LEGEND ABBREVIATIONS MATERIALS COMPLIANCE:
NOTES: EXISTING SITE BOUNDARY WATER SERVICES ASSOCIATION OF ALL MATERIALS USED IN THE WORKS SHALL
WSAA
EXISTING PROPERTY BOUNDARY AUSTRALIA COMPLY WITH THE CURRENT IPAM LIST
1. FOR GENERAL AND WATER NOTES REFER DRG 200437-C-00201.
NSC NOOSA SHIRE COUNCIL
2. NOTWITHSTANDING THE DETAILS SHOWN ON THE DRAWINGS, ALL WORKS EXISTING SEWER MAIN
WW WATER & WASTE
SHALL BE CONSTRUCTED IN ACCORDANCE WITH LOCAL W&W AGENCY AND EXISTING WATER MAIN DBYD
ASSOCIATED SEQ CODE STANDARD DRAWINGS AND SPECIFICATIONS. AC ASBESTOS CEMENT
EXISTING U/G TELECOMMS DBYD WARNING!
3. ALL DISTURBED AREAS SHALL BE TOPSOILED (MINIMUM THICKNESS 100mm) CI CAST IRON
EXISTING U/G OPTIC FIBRE DBYD BEWARE OF UNDERGROUND SERVICES
AND PROVIDED WITH GRADE 'B' TURF. CICL CAST IRON CEMENT LINED
EXISTING U/G TELECOMMS/ OPTIC FIBRE DBYD POSITION OF EXISTING UNDERGROUND SERVICES
4. TEMPORARY WORKS SIGNAGE TO BE ERECTED AS PER DEPARTMENT OF DI DUCTILE IRON SHOWN IS APPROXIMATE ONLY. EXACT POSITION
TRANSPORT & MAIN ROADS (DTMR) MANUAL OF UNIFORM TRAFFIC EXISTING STORMWATER DBYD
DICL DUCTILE IRON CEMENT LINED SHALL BE PROVEN ON SITE BY THE CONTRACTOR
CONTROL DEVICES (MUTCD), CURRENT EDITION. EXISTING O/H ELECTRICITY DBYD PRIOR TO COMMENCEMENT OF CONSTRUCTION
MH MANHOLE
PROPOSED WATER
DN DIAMETER NOMINAL
PROPOSED SEWER
PE POLYETHYLENE
SS STAINLESS STEEL
UPVC UNPLASTICISED POLYVINYL CHLORIDE
Last Plotted: 2020-12-18
VC VITRIFIED CLAY
Last saved by: GRANT(2020-12-18)
North Point Scale Horiz. Datum Client Consultant Project Drawing
LOCAL Drawn GM Drawing No. Rev No.
MIDSON CONSTRUCTIONS 33 TEWANTIN ROAD WATER RETICULATION
0 2.5 5 Vert. Datum (QLD) PTY LTD COOROY, QLD, 4563 Design GM LAYOUT & DETAILS
A1 1:100
m AHD
MULTIPLE DWELLINGS DEVELOPMENT Check LS
200437-C-00202 A
A FOR OPW APPROVAL 17.12.20 LS RL Datum CIVIL | STRUCTURAL | GEOTECHNICAL OPW APPLICATION Approved Signed
P1 PRELIMINARY 16.11.20 LS OPM 24963 COPYRIGHT © All rights reserved. Sheet
Rev Revision Description Date Approved RL 125.924
This work is copyright and cannot be reproduced
or copied in any form without the prior consent
SUNSHINE COAST | BRISBANE | GOLD COAST
www.arcosgroup.com.au | ABN 51 640 311 842
Date 17.12.20 L.SWANN
RPEQ 21223
Status NOT FOR CONSTRUCTION
Size A1