Architecturals REV E
GENERAL NOTES:
- DO NOT SCALE FROM THIS DRAWING - ALL BUILDINGS SHALL BE PROTECTED AGAINST TERMITE
WRITTEN DIMENSIONS TAKE PRECEDENCE ATTACK IN ACCORDANCE WITH AS 3660.1 AND A DURABLE
OVER SCALE. NOTICE SHALL BE PLACED IN THE METER BOX INDICATING
- ANY DISCREPANCIES WHICH THE TYPE OF BARRIER AND REQUIRED PERIODICAL
CONTRACTOR MAY FIND IN THIS DRAWING INSPECTIONS.
MUST BE BROUGHT TO THE ATTENTION OF
EVOKE ARCHITECTS PRIOR TO SAFETY GLAZING TO BE USED IN THE FOLLOWING CASES-
COMMENCEMENT OF WORK. - VERIFY ALL i) ALL ROOMS WITHIN 500mm VERTICAL OF THE FLOOR
DIMENSIONS PRIOR TO ORDERING OR SHOP ii) BATHROOMS- WITHIN 1500mm VERTICAL OF THE BATH
FABRICATION. BASE
- SMOKE DETECTORS TO BE WIRED INTO iii) FULLY GLAZED DOORS
ELECTRICITY MAINS AND TO COMPLY WITH iv) SHOWER SCREENS
NCC, PART 3.7.2. v) WITHIN 300mm OF A DOOR AND <1200mm ABOVE FLOOR
SD LEVEL
vi) WINDOW SIZES ARE NOMINAL ONLY, ACTUAL SIZES WILL
- ALL GLAZING TO COMPLY WITH AS 1288-2006 VARY WITH MANUFACTURER, FLASHING ALL ROUND.
GLASS IN BUILDINGS & AS 4055-2012 FOR
WINDLOADING. NOTE: GLAZING REQUIREMENTS MAY BE DIFFERENT FROM
- ALL CONSTRUCTION TO BE IN ACCORDANCE THAT STATED UNDER BUSHFIRE CATEGORY
WITH THE RELEVANT AUSTRALIAN REQUIREMENTS REFER 'BAL RATING'
STANDARDS, THE NATIONAL CONSTRUCTION
CODE & LOCAL AUTHORITY REGULATIONS FOOTINGS NOT TO ENCROACH TITLE BOUNDARIES OR
- FOOTINGS HAVE BEEN DESIGNED IN EASEMENTS. IT IS RECOMMENDED THAT WHERE BUILDINGS
ACCORDANCE WITH ASSOCIATED SOIL TESTS ARE TO BE LOCATED IN CLOSE PROXIMITY OF BOUNDARIES,
AND/ OR ENGINEERS SPECIFICATIONS. A CHECK SURVEY BE CONDUCTED BY A LICENSED
- DRAWINGS TO BE READ IN CONJUNCTION SURVEYOR.
WITH ATTACHED ENGINEERS NOTES.
- ARTICULATION JOINTS TO ENGINEERS ALL STEELWORK IN MASONRY TO BE HOT DIP GALVANISED.
DESIGN REPORT
- LOH - WHERE INDICATED TO BE REMOVABLE ALL WET AREAS TO COMPLY WITH NCC 3.8.1.2 AND AS 3740.
DOORS WITH LIFT OFF HINGES IN SPLASH BACKS SHALL BE IMPERVIOUS FOR 150mm ABOVE
ACCORDANCE WITH NCC 3.8.3 SINKS, TROUGHS AND HAND BASINS WITHIN 75mm OF THE
- REFER ENGINEER'S PLAN FOR EXPANSION WALL.
JOINT LOCATIONS
- WATER PROOFING TO WET AREAS TO PROVIDE WALL TIES AT 600mm SPACINGS BOTH VERTICAL
COMPLY WITH NCC, PART 3.8.1 AND HORIZONTAL AND WITHIN 300mm OF ARTICULATION
- SMOKE ALARMS TO BE INTER-CONNECTED JOINTS. BRICK TIES TO BE STAINLESS STEEL.
SUSTAINABILITY COMPLIANCE THERMAL INSULATION; INSULATION TO CEILING AND
REFLECTIVE FOIL TO EXTERNAL WALLS OR AS PER ENERGY
1. TRIPLE 'A' RATED SHOWER ROSES. RATING REFER SARKING REQUIREMENT UNDER BUSH FIRE
2. DUAL FLUSH TOILETS (6 LITRE FULL FLUSH / CATEGORY. BEDROOMS REQUIRE MINIMUM 10% LIGHT & 5%
3 LITRE HALF FLUSH). VENTILATION TO TOTAL FLOOR AREA.
3. 500kpa WATER PRESSURE-LIMITING
DEVICES.
4. ENERGY EFFICIENT LIGHTING TO 80% OF RELEVANT AUSTRALIAN STANDARDS
DWELLING INTERNAL FLOOR SPACE.
- CONCRETE CONSTRUCTION TO COMPLY WITH
TERMITE PROTECTION: NATIONAL CONSTRUCTION CODE.
TO AS3660-2017 "TERMSPEC" TERMITE
MANAGEMENT SYSTEM TO ALL SLAB - TIMBER STRUCTURE STANDARD AS 1720.3- 2016
PENETRATIONS AND PERIMETER OF SLAB.
CONCRETE SLAB TO BE DESIGNED AND - TIMBER CONSTRUCTION AS1684 - 2010
CONSTRUCTED IN ACCORDANCE WITH AS2870. - MASONARY STRUCTURES AS4773-2010
REFER ENGINEERS PLAN FOR EXPANSION JOINT - CONCRETE STRUCTURES AS3600-2018
LOCATIONS. - CONCRETE ROOF TILES AS2049-2002
- RESIDENTIAL SLABS & FOOTINGS AS2870-2011
SLAB: - WINDOW & GLASS INSTALLATION AS2047 AND AS1288. ON SITE HOUSE RELOCATION AT:
STEPDOWNS TO EXTERNAL SURFACES TO - BARRIERS FOR SUBTERRANEAN TERMITES TO
COMPLY WITH THE NCC. CONCRETE SLABS, COMPLY WITH THE PROVISIONS OF PART 3.1.3 OF THE
1174 POMONA KIN KIN RD, KIN KIN
PATHS & DRIVEWAYS NOT DESIGNED BY NCC AND WITH AS3660.1-2014
ENGINEER ARE NOT PART OF THIS APPLICATION. - WIND LOADS FOR HOUSING AS4055-2012
- STEEL STRUCTURES AS4100-2016
PLUMBING: - DAMP PROOF COURSE & FLASHINGS AS/NZS2904
PLUMBER / DRAINER TO VERIFY ALL DIMENSIONS - PROTECTION OF MASONRY WALL TIES TO COMPLY
PRIOR TO POSITIONING UNDERSLAB POINTS. WITH THE PROVISIONS OF PART 3.3.3.2 OF THE NCC.
MEASUREMENTS MAY VARY. FLOOR WASTE - PROTECTION OF LINTELS IN MASONRY TO COMPLY
FIXTURES TO BE POSITIONED AT THE TIME OF WITH THE PROVISIONS OF PART 3.3.3.4 OF THE NCC.
CONSTRUCTION.
ALL CONSTRUCTION TO BE IN DATE DESCRIPTION REV
ACCORDANCE WITH THE NCC & RELEVANT
15.03.2021 PRELIMINARY A CLIENT NAME:
AUSTRALIAN STANDARDS. FULL
STRUCTURAL CERTIFICATION IS REQUIRED.
DO NOT SCALE FROM DRAWINGS. CONFIRM 06.04.2021 MINOR AMENDMENTS B VICTORIA NICHOLLS & NICK MARKS
ALL DIMENSIONS ON SITE PRIOR TO
COMMENCING ANY FABRICATION, SETOUT 27.07.2021 NEW HOUSE LOCATION C PROJECT ADDRESS:
OR WORK. ANY COSTS ARISING FROM
INCORRECT DIMENSIONING IS THE 23.08.2021 NEW HOUSE LOCATION D 1174 POMONA KIN KIN RD, KIN KIN , QLD, 4571.
RESPONSIBILITY OF THE CONTRACTOR IF
EVOKE ARCHITECTS IS NOT CONTACTED 24.08.2021 NEW HOUSE LOCATION E SHEET NAME:
PRIOR TO CONSTRUCTION. VERIFY
LOCATION OF EXISTING SERVICES BEFORE PRO SHEET NUMBER REV COVER SHEET
COMMENCEMENT OF WORK.
838 A - 01 E
COPYRIGHT EVOKE ARCHITECTS ALL RIGHTS RESERVED. THIS WORK CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS IN PART OR WHOLE WITHOUT WRITTEN PERMISSION OF EVOKE ARCHITECTS.
© EVOKE ARCHITECTS 2021 - | ALVIN: 0421 244 897 DARCY: 0421 159 555 | E: [email protected] |