20180106 - RPEQ Inspection Certifcate F16 · 131999.982846.2

Attached to the e-mail Change to DA - 131999.982846.2.

of 2

Text shows just the words. Original shows the document exactly as it was published.

                                                            Department of Housing and Public Works

                                                            Form 16—Inspection
                                                            Certificate/Aspect Certificate/QBCC
                                                            Licensee Aspect Certificate Version 5 – July 2017
 NOTE: This form is to be used for the purposes of section 10(c) and 239 of the Building Act 1975 and/or sections
 32, 35B, 43, 44 and 47 of the Building Regulation 2006.
 1. Indicate the type of
 certificate                               Inspection Certificate for
 The stages of assessable building
 work are listed in section 24 of the                  Stage of building work (for single detached class 1a or class 10 building or
 Building Regulation 2006 or as                        structure)
 conditioned by the building certifier.
 An aspect of building work is part of
 a stage (e.g. waterproofing).
                                                       Aspect of building work :
                                                       Retaining Wall Footings




                                                     QBCC Licensee Aspect Certificate
                                           Scope of the work
                                           Scope of the work covered by the licence class under the Queensland Building and Construction
                                           Commission Regulation 2003 for the aspect being certified, e.g. scope of work for a
                                           waterproofing licence is “installing waterproofing materials or systems for preventing moisture
                                           penetration”. An aspect being certified may include “wet area sealing to showers”.




 2. Property description                   Street address (include no., street, suburb/locality and postcode)
 The description must identify all          18 Arakoon Crescent
 land the subject of the application.
 The lot and plan details (e.g.             SUNSHINE BEACH                                                 Postcode 4567
 SP/RP) are shown on title
 documents or a rates notice.              Lot and plan details (attach list if necessary)
 If the plan is not registered by title,    Lot 791 RP 48111
 provide previous lot and plan details.
                                           In which local government area is the land situated?
                                            Noosa Council

 3. Building/structure                     Building/structure description                                Class of building/structure
 description                                Free Standing Retaining Wall                                        Class 10B

 4. Description of component/s
 certified                                  Depth of Excavations, Adequacy of Foundation Base, Placement of
 Clearly describe the extent of work        Reinforcement
 covered by this certificate, e.g. all
 structural aspects of the steel roof
 beams.


LOCAL GOVERNMENT USE ONLY
          DATE RECEIVED                                                       REFERENCE NUMBER/S
Full text of the other 1 page

Page 2

5. Basis of certification
Detail the basis for giving the                AS/NZS 1170.0 & 1 - 2002 Structural Design Actions - Part 0: General Principles, - Part 1:
certificate and the extent to which            Permanent, Imposed and Other Actions, - Part 2-2011: Wind Actions
tests, specifications, rules, standards,       AS2870.1-2011 Residential Slabs and Footings - Construction
codes of practice and other
publications, were relied upon.                AS3600-2009 Concrete Structures
                                               AS3700-2007 Masonry Structures
                                               AS4678-2002 Earth Retaining Structures

6. Reference documentation
                                               Neil McKenzie & Associates Pty Ltd Drawings Q17—304-01, -02, -03
Clearly identify any relevant
documentation, e.g. numbered
structural engineering plans.




7. Building certifier reference               Building certifier reference number                 Development approval number
  number and development
  approval number
                                               20160223

8. Building certifier, competent              Name (in full)
  person or QBCC licensee
  details
                                               James Neil McKenzie{B.E.(Civil),M.I.E Aust}
A competent person must be                    Company name if applicable                              Contact person
assessed as competent before                   Neil McKenzie & Associates Pty. Ltd.                    Neil McKenzie
carrying out the inspection.
The builder for the work cannot give a        Phone no. business hours          Mobile no.                         Fax no.
stage certificate of inspection.               (07) 3862 1886                    0411 746 878                       (07) 3862 1397
A competent person is assessed by
the building certifier for the work as        Email address
competent to practice in an aspect of          [email protected]
the building and specification design,
because of the individual’s skill,            Postal address
experience and qualifications. The
competent person must be registered
                                               14/699A Sandgate Road
or licensed under a law applying in the        Clayfield                                                             Postcode 4011
State to practice the aspect.
If no relevant law requires the               Licence class                                      Licence number
individual to be licensed or registered,       R.P.E.Q                                             2097
the certifier must assess the individual
as having appropriate experience,             Date approval to inspect received from building certifier
qualifications or skills to be able to give
the help.


9. Signature of building certifier,
  competent person or QBCC                    Signature                                                       Date
  licensee
Note: A building certifier must sign this                                                                       Digitally signed by Neil
form for temporary swimming pool                                                                                McKenzie
fencing under section 4 of Schedule 1
of QDC MP 3.4.
                                                                                                                Date: 2018.03.05
                                                                                                                13:28:36 +10'00'




  The Building Act 1975 is administered by the Department of Housing and Public Works

Used in these records

About this file

File size
427 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

20180106 - RPEQ Inspection Certifcate F16.pdf · 427 KB (small file)