MITCHELLDESIGN

Demolition of the Existing House

The existing house is to be demolished. Its adaptation has been investigated but its layout, its condition and the general quality of its construction is
neither suitable to clients’ needs nor readily or for that matter economically adaptable.

The specific difficulties are the number of ievels and the planning of intemal spaces which do not allow the provision for adaptability possible.

Removal is currently being investigated although preliminary advice indicates that this is difficult for the sorts of reasons which make it impossible to
adapt. Advice obtained by the client indicates that a significant proportion of the material and fittings in the house is likely to be able to be recycled.

Overlays

The Noosa Plan identifies that the property does not trigger Biodiversity (environmental protection) or Natural Resources (coastal protection)
Overlays.

The Natural Hazard Overlay, however, determines that the property lies within a Medium Bushfire Hazard Area.

The Building Code of Australia contains provisions applying to building in bushfire prone areas.

Building certification will require that the building be constructed to reduce ember attack.

To comply with AS3959-1999, the use of fire retardant building materials, door seals, ridge seals, sealed roof/wall junctions and screened window
openings, vents and weepholes may need to be provided. :

This will be addressed in the next stage of design

Rainwater Tanks .
Map 1 of Schedule 8 determines that the property is sited within a rainwater tank area (3000litres).

User Guide 23 states that “if a property is tocated in a Bushfire Hazard Area a requirement to provide a rainwater tank (5000 litres) accessible for
the purposes of fire fighting. (Note that a filled swimming pool does not satisfy this requirement). The tank must therefore be compatible with local
fire service requirements’.

The relationship of the proposed house to the topography will result in significant areas of undercroft which will provide accommodation for
rainwater storage tanks. .
: me

Used in these records

About this file

File size
6.2 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_0965 - MCU - Detached House [As Published].pdf · 6.2 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.