Council archive · source document
Appendix E - David Moore Noise report · 132007.2446.03
Attached to the e-mail Other Change application (Extension of Existing Visitor Hostel - 21 Beds) - 132007.2446.03.
Tamobrojo Pty Ltd Environmental Noise Level Impact Assessment for Proposed Expansion of Existing Backpacker Accommodation onto 106 Pacific Avenue, Sunshine Beach Page 9 of 18 At the closest adjoining residence to the north-west the noise of people laughing and talking would be: • covered communal area: 54 dB(A) LAeq,adj,T @ 8 m – 4 (distance) – 8 (acoustic barrier/fence between communal area and staff carparking space = 42 dB(A); • outdoor DOSA: 54 dB(A) LAeq,adj,T @ 8 m – 5 (distance) – 8 (acoustic barrier/fence between outdoor DOSA and staff carparking space = 41 dB(A). The noise limits for the above noise source, at the adjoining residence to the north-west, are: • daytime: 58 dB(A) LAeq,adj,T; • evening: 51 dB(A) LAeq,adj,T; • night-time: 44 dB(A) LAeq,adj,T. All of the above noise limits are complied with for the complete 24-hour day, provided the fence between the communal area and DOSA and the staff carparking space is an acoustic barrier. Plant Noise Plant noise from the proposed backpacker accommodation could include airconditioning units. Whilst at the time of preparing this report no detail was available with respect to plant it has been assumed that the 6-bed Dorms would be airconditioned, along with the Manager and Staff facilities and the cinema. Based on previous noise assessments conducted by the consultant typical airconditioner noise levels are 64 dB(A) LWA. At the closest adjoining residence to the north-west the noise level of the airconditioning units, assuming a total of 6 units (dorms × 3, cinema × 1, staff/manager × 2) would be: • dorms: 64 dB(A) LWA + 6 (3 units) – 26 (distance) = 44 dB(A); • cinema: 64 dB(A) LWA – 30 (distance) – 8 (fence/barrier between communal area and staff carpark) = 26 dB(A); • staff: 64 dB(A) LWA + 3 (2 units) – 30 (distance) = 37 dB(A); • combined: 44 + 26 + 37 = 45 dB(A) LA90,T. The noise limits for plant noise at the adjoining residence to the north-west are: • daytime: 53 dB(A); • evening: 46 dB(A); • night-time: 39 dB(A). The night-time noise limit is exceeded by the three airconditioning units associated with the Dorms. Therefore, if the Dorms are to be airconditioned, EITHER the airconditioning units need to be located remote from the adjoining residence to the north-west OR these airconditioning units are acoustically treated with an acoustic enclosure OR acoustic barrier on the common boundary adjacent to these airconditioning units. At the closest adjoining residences to the north-east the noise level of the airconditioning units, assuming a total of 6 units (dorms × 3, cinema × 1, staff/manager × 2) would be: • dorms: 64 dB(A) LWA + 6 (3 units) – 36 (distance) = 34 dB(A); • cinema: 64 dB(A) LWA – 38 (distance) – 15 (intervening building) = 11 dB(A); • staff: 64 dB(A) LWA + 3 (2 units) – 32 (distance) = 35 dB(A); • combined: 34 + 11 + 35 = 38 dB(A) LA90,T. David Moore & Associates Pty Ltd Our reference: R18018/D3310/Rev.0/19.04.18
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix E - David Moore Noise report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 805 KB (small file)
- File type
No other editions are linked here.