Original source · versioned page text
EGX_PROD_n7653942_55_and_70_Carpenters_Road,_Cooroy_L2_RP200519,_L1_SP248288
2
3. Access to the easement and access along the easement must be available to
Energex personnel and heavy equipment at all times.
4. Clearance from any building/structures to the existing electricity wires must be
maintained accordance with the Electrical Safety Regulation 2013 at all times.
5. Natural ground levels on the easement are not to be disturbed without Energex
approval. Detailed civil design drawings showing any proposed cut and fill levels
on the easement and the location of the Energex assets in relation to the
proposed development are to be approved by Energex prior to the
commencement of any works on site.
6. 10 metres clear access must be provided around all towers and pole structures
after the completion of any works on the easement.
7. No landscaping/planting is permitted on the easement with the exception of turf.
8. The proposed development must ensure no stormwater worsening within
Energex easements.
9. Any future works in the vicinity of Energex assets are to be carried out in
accordance with the Electricity Entity Requirements: Working Near Overhead
and Underground Electric Lines. This guideline can be accessed via the following
link: https://www.energex.com.au/__data/assets/pdf_file/0004/344470/Working-
Near-Overhead-and-Underground-Electric-Lines-WP1323.pdf.
Should you require any further information on the above matter, please contact Maddison
Low on 0456 836 609.
Yours faithfully,
Maddison Low
Town Planner
Reference: HBD 7653942
Have you seen our fact sheets?
See the ‘considerations when developing around electricity infrastructure’ section of our website
www.energex.com.au/referralagency