Council archive · source document
Attachment 6. ES01 DMA Engineering - Preliminary Electrical Plans · OPW22/0319
Plans and drawings: the text below has words only, no drawings.
PP®) PRIVATE PROPERTY POLE. OVERHEAD CONNECTION BY ENERGEX 0 ] | MAIN SWITCHBOARD | CURRENT RATING: 160A | | | FAULT LEVEL: 10kA FOR 1 SEC | CONSTRUCTION: FORM 1 PROTECTION: IP56 | LOCKABLE DOORS (ENERGEX LOCK) 1# | CABLE # DB NAME CABLE SIZE SINGLE LINE LEGEND | ORE ES TANDING WITH PLINTH AND SLAB LOCKABLE | Qa MSB 4x 1C 70mm? Cu XLPE/PVC ———— SINGLE PHASE | | @ UNIT 1 DB (DB-1) 2C 16mm? + E Cu XLPE/PVC s ' ——*— THREE PHASE | | Oo UNIT 2 DB (DB-2) 2C 16mm? + E Cu XLPE/PVC | | Oo UNIT 3 DB (DB-3) 2C 16mm? + E Cu XLPE/PVC bo MAIN SWITCH OR ISOLATOR, FAULT MAKE LOAD BREAK | | o UNIT 4 DB (DB-4) 2C 16mm? + E Cu XLPE/PVC | | o UNIT 5 DB (DB-5) 2C 16mm? + E Cu XLPE/PVC xo CIRCUIT BREAKER, RATING AS INDICATED | SUPPLY AUTHORITY | a UNIT 6 DB (DB-6) 2C 16mm? + E Cu XLPE/PVC RCD | METERS | O UNIT? DB (DB7) 30 lemm? + E Cu XLPEIPVC xX 30mA RESIDUAL CURRENT DEVICE CIRCUIT BREAKER, RATING | | oO UNIT 8 DB (DB-8) 2C 16mm? + E Cu XLPE/PVC | 63A 63A 63a 63a 328 | 40) UNIT 9 DB (DB-9) 2C 16mm? + E Cu XLPE/PVC a—D REMOVABLE LINKS | | a UNIT 10 DB (DB-10) 2C 16mm? + E Cu XLPE/PVC aS RELAY CONTACTOR (NORMALLY OPEN) | _ COMMUNITY SECTION | | J J J J i | CABLE SCHEDULE a RELAY / CONTACTOR (NORMALLY CLOSED) REFER | ADJACENT SPARE | | TABLE aA aA aA ®* POLES | —(ur}— KILOWATT HOUR METER (ENERGEX AUTHORITY METER) @ w @ @ 0 0 0 Oo | | SWITCHBOARD NOTES —tQ7— METERING CURRENT TRANSFORMER - ee ee oo a | 1. ALL CABLES ARE TO BE COPPER. TYPICAL TYPICAL 2. CONFIRM METERING AND SWITCHES ARRANGEMENT WITH SUPPLY —_ —_ —_ —_ SUBCIRCUITS SUBCIRCUITS AUTHORITY PRIOR TO MANUFACTURE OF SWITCHBOARD. (POWER) (LIGHTING) MINIMUM 1 x 2C 3. PROVIDE EARTHING CONDUCTORS AS REQUIRED TO AS/NZS 3000. 6mm2 +E 4. ALL SUBMAINS CABLE SIZES ARE MINIMUM. VERIFY AND CONFIRM EXACT SIZES PRIOR TO INSTALLATION. 5. ALL CABLES ENTERING THE MSB AND ALL DBs TO BE GLANDED TO KEEP |.P. RATING OF BOARDS. r eee 7 6. | PROVIDE LABELS TO ALL CIRCUIT BREAKERS AND EQUIPMENT. | | 7. EXTERNAL LIGHTING TO BE TIME SWITCHED AND PE CONTROLLED. | | | | 63A 0A _RCD pb ~o J x Set LIGHTING SPACE 0A RCD | a POWER CIRCUIT | | | | tL x SPACE | TYPICAL TENANCY SWITCHBOARD (1 - 10) ENCLOSURE - P42 CONSTRUCTION - FORM1 CURRENT RATING - 100A FAULT WITHSTAND - 6kAFOR1 SEC CHASSIS - 12 POLE MINIMUM NOTE: FINAL RATINGS OF ALL CIRCUITS TO SUIT EQUIPMENT SELECTION. NOT FOR TENDER D> Rev D> Description > Date D> Client : > Architect : D> Project : > Service & Title : > Created Date : D Scale : N.T.S. 03 / 2023 P1 PRELIMINARY ISSUE 01/03/23 TOOLAR ST TOWN HOUSES ELECTRICAL SERVI CES ee —— ~ ND ' ND JAMESON/STIRLING ROBIN SPENCER i at SCHEMATICS AND DETAILS > Approved : > Plot Date : ARCHITECTS PTY. LTD. engineers 25-27 TOOLAR STREET, TEWANTIN 01/03/2023 L 18, 135 Wickh t Spring Hill @LD 4000 1 7 2839 3050 QLD 4565 > Job Number : > Drawing Number : DRev: eVEl Oo, Icknam lerrace, spring Fl [email protected] | DMAengineers.com.au 1 1844 ES02 P1 01.03.2023@16:33:25 \\dma.local\DMA\Data\Data01\Synergy\Projects\1 1844 Toolar St Townhouses — NBN\Drawings\DMA\11844-ES02.dwg XREF : 11844-A1_hoz LOGIN NAME : NicholasD
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment 6. ES01 DMA Engineering - Preliminary Electrical Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.6 MB (small file)
- File type
No other editions are linked here.