{/ SURVEY LOCATION
The red dashed lines on this Plan represent an
approximation of the boundary positions for this site and
may not be located in its true position in relation to the
Levels and Features shown here on. Additional Survey
SEE _ work is required to position the boundary and the
Features in their correct relation to each other. Please
NOTE contact Axis Surveys for additional advice before relying
L on the boundary position on this Plan for design purposes
( SETOUT EXTRA FEES ALERT (Designer/Builder Etc.)
This Contour and Feature Survey as prepared by Axis Surveys does not
address the location of boundaries, Because of the age of the subject plan /
and / or missing boundary pegs, Axis Surveys will require additional fees for
extra control work to enable us to setout any proposed building work. Please
[ contact this office for further advice
\ Sewerage Note
Sewer manhole/s not located
NOTE must be found on site
prior to construction
Tree Legend
@=Trunk Dia
(Total Canopy)
—T Te
TREE SCHEDULE
No. | Name | T'O' | Spr'@' | 'H
1 TREE 0.30 m 3.0m 5.0m
2 TREE 0.20 m 2.0m 4.0m
3 TREE 0.30 m 4.0m 5.0m
4 TREE 0.30 m 5.0m 5.0m
5 TREE 0.30m 5.0m 5.0m
6
7
8
9
TREE 0.50m 7.0m 6.0m
TREE 0.40m 6.0m 7.0m
TREE 0.20m 3.0m 5.0m
TREE 030m 3.0m 7.0m
10 TREE 0.20m 2.0m 4.0m
it TREE | 030m] 5.0m | 6.0m
12 TREE | 040m | 3.0m | 5.0m
13 TREE | 040m | 3.0m | 5.0m
HO
q
“———— Mas
Approximate House
Connection Plotted —
From Statutory or
Supplied Records
Approx. Invert Level 7.08m
Approx. .84m deep
Saoe LL
H
House
AHO
Patio
IE
Existing
ighset
Sewer M/H
Not Located
Peg
Found
Wall
Block Ret.
Existing Concrete |
Timber Fence 9.25. 8.88
8.18
90°0'
I
Ws
Timber Fence
32
BUSH LAND
Metal Fence on Existing Timber Sleeper Retaining Wall
7.53 7.38 Gat 182°13'20"
‘cee nee sate 7.51
7. 3 TT
Sewer Mit” 75,088 ‘
Not Located
[et
Deck
Floor Level =
No Mk
Found
2
Step
1926 13.
3.42 Existing Coneretes
3. E\
f
19g]
TBM Spike in Bitumen
AHD RL / m 13.461
' Plover Street
1326) Block Ret, Wall
11 Y PProximate Ss
ewer Line Lo
Approximate House
Connection Plotted
From Statutory or
Supplied Records
Cation (See note)
| Approx. Invert Level 7.32m
Approx. .65m deep
jo7e RL 10.70 :10-78
Dg ° 73
oT e = eS §
aftr es TTS
Deck _ Floor Level
RL 14.34
Floor Level
RL 11.73
Roof Peak Existing Q Gutterline
“pAIRE 19.05 Highset Roof Peak
s House RL 19.05
1.00_
ws
we . Floor Level e
S &
Gao a RL 2.97 Existing
12.70 a Highset
= House
Hi1ga"" 11.9%
wre 12.58 12.58
Existing Concrete L__
Block Ret.Wal
8
8
=
5
i"
5
2
E
=
Approximate Sewer Line Location (See note)
Contour & Feature Survey «
ra sci S
SURVEYS
Unit 5/23 Overlord Place, ACACIA RIDGE, Qld, 4110
Ph (07) 3363 8100 www.axissurveys.com.au
LOT 5 on — P9313
#24 Plover Street
Suburb Peregian Beach
Local Auth Sunshine Coast Reg.Council
Area 506m2
Client:
Reitsma & Associates
Order No:
NOTES TO BE READ BEFORE USING THIS PLAN
This Plan has limitations regarding its use for
some applications. Please contact this office if
there is any doubt about the suitability of this
plan for the intended use. These notes form part of
this plan and they must remain with the plan or
any copies. The limitations of this plan are detailed
in the link below, with the main ones being:-
1, This plan has been prepared for our client &
should not be used by others without approval.
2, The boundaries shown have been sourced
from the subject survey plan or as noted, and
have not been checked.
3, Distances from features to the shown
boundaries should not be used or relied upon.
4, If positional accuracy is critical a boundary
identification survey may be required.
5, The certificate of title has not been searched
and should be checked for any encumbrances.
6. The contours may not represent the local
authority's definition of “Ground Level”
7. A flood search has not been carried out.
Check with local council for min. and max.
construction heights.
8. Non visible services (if shown), have been
plotted from the relevant authority's records
or from other sources and may not be
accurate. Services should be exposed
before design or construction commences.
9, The north point has been taken from the survey
plan and may not be suitable for all uses.
Refer to this link for more information
www. axissurveys.com.au/alertsanddisclaimers/
Issue Date Amendment By
A 23/03/21 _| Original Issue GEO1
B
C
D
E
FE
Ty po
Site No: 2101583 Scale:
Order No: X427758 .
Level Datum: AHD 1:200
Surveyed: SH/CF PAGE
Date: 18/03/21} 1 OF 1
See the original