8M HEIGHT LIM
+7.5M IT
9
+4.5M
8M HE
IGHT L
IMIT
RELAXATIONS
1 1. WALL & EAVE THROUGH 2M SIDE SETBACK
1 2. PLANTER THROUGH 2M SIDE SETBACK
3. WALL & ROOF THROUGH 1.5M SIDE SETBACK QDC COMPLIANT
GARAGE 3 4. EAVE THROUGH 2.5M SIDE SETBACK
QDC compliant 5. PLANTER THROUGH 2M SIDE SETBACK
6. WALL THROUGH 1.5M SIDE SETBACK
2
7. POOL DECK THROUGH 6M REAR SETBACK
8. TRANSPERENT BALUSTRADE >2M ON BOUNDARY
9. EAVE THROUGH 2M SIDE SETBACK
SOUTH EAST
2M
AB
OV
EN
AT
7
UR 8M HE
AL IGHT L
1M IMIT
AB
OV
EN
4 +8.0M
AT +7.5M
UR
AL
L IM IT
HT
EIG
8 MH
8 +4.5M
5
GARAGE 2M ABOVE NATURAL
6
SOUTH WEST EIG
HT
L IM I
T 8M
HEI
GHT
LI M IT
2M ABOVE NATURA
L
FENCE A
M H
8
1M ABOVE NATURAL
+8.0M
+7.5M
9
PT
8M
HE
EW A
IG H
TL
VI AD
IM I
T
1 1 DA3 Development Approval
issue issue / amendment
+4.5M
RE OR
21.03.22 LF AB JH
2 NORTH WEST issue date drawn by
PF
client
2M ABOVE NA 6 5 Ingrid & Nick Hutton
TURAL project
M
Hutton Plover St
3
TE
location
GARAGE 2M AB
OVE N
24 Plover St Peregian Beach
QDC compliant ATURA
L PLANNING ENVELOPE
8 Aboda Lee Foster • director Scott Falconer • director
Design p - 0424 620 247 p - 0431 267 157
1M ABOVE NA Group e - [email protected] e - [email protected]
TURAL the aboda design group trust Level 2 1794 David Low Way Coolum Beach,
ABN 56 266 884 746 Q. 4573. PO box 2449 Noosa Heads Q 4567
t/a aboda design group • BSA License -150580097 • www.aboda.com.au
• This drawing is to be read in conjunction with engineers drawings & reports • Construction
to comply with all relevant SAA & NCC Codes & standard Bldg By-law 1975 & as amended •
Copyright for design & drawings remain the property of the authors • Verify all dimensions on
site prior to commencement of any works • These drawings are not to be used for scaling.
setback means the minimum distance from
scale as shown @ A3 issue
any lot boundary to a building or structure,
drawing no.
excluding eaves, roof overhangs and
awnings provided they encroach no more
than 600mm into the setback distance. WD.151 DA3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.