Original source · versioned page text
Stormwater Management Report
The original of this document is very large (11.4 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Original PDF page 32, section 2. The text section number identifies this passage in the reader.
N
S
S
FUTURE STUDY
window
fall
flush
6,000 OMP (hood) LIFT BELOW
awning below
8
E
wc
N 8° 11' 9"
7
6
.
MASTER
4
5,870
5,870
fall
1
POOL
line of wall below
B BED B
artwork
window
WD.602 WD.602
12
.75 ENS. FT
FFL 15.910 BELOW
KITCHEN DINING
b
DRIVEWAY TF
PANTRY
12
window
BELOW
.75
LAUNDRY BELOW BELOW
fall
dr.
hood
sh BELOW
window
line of wall below 2m SIDE SETBACK
window ROOFTOP PLANTER
N
8
9
2
°
1
3
.
5
4
8
'
0
5
7
"
E
concealed gutter
4 4
RWH
2,070 OMP (wall)
1.5m SIDE SETBACK
S
S
S
8
8
8
9
9
9
2
2
2
°
°
°
1
1
1
3
3
3
.
.
.
4
4
4
5
5
5
'
'
'
5
5
5
5
5
5
6
6
6
7
7
7
"
"
"
W
W
W
1,500 OMP
GARAGE
(planter)
1,410
1,410
BELOW
5 33.561
270°0'
5
S
8
9
3
°
3
3
.
4
5
'
6
5
1
7
"
W
9.5
9.2
9.7
11.25
10.75
8.25
8.75
9.0
10.50
11.50
8.50
11.75
6,222 OMP (hood)
11.
10.25
0
5
5
0
0 0
PT
EW A
2,300 5,910 2,800 8,590 3,700 4,480
VI AD
C
A B D
WD.602 C D WD.601 E F G DA3
issue
Development Approval
issue / amendment
RE OR
21.03.22 LF AB JH
issue date drawn by
EXT. FINISHES LEGEND WALL LEGEND GENERAL LEGEND FLOOR FINISH LEGEND
PF
FCA fibre cement awning. PF compliant pool fencing client
Ingrid & Nick Hutton
AS aluminium screen. FC fibre cement ext. cladding. PW parapet wall. RC masonry blockwork
D04 denotes door number FT1 FT2 Indicates extent of TILE project
M
Hutton Plover St
AL aluminium louvres, refer sched. FG fascia gutter. PS patio slab. W04 denotes window number
TE
location
RC pool shell/off form concrete
C Indicates extent of CARPET 24 Plover St Peregian Beach
ASD aluminium sliding door. FT1 floor tile (no refers to type). PV photovoltaic cells. RL 17.200 denotes finished floor level
AFD aluminium framed door. fire fireplace RWT rain water tank.
90MM ext. timber frame
+ RL 17.700 denotes spot level
TF TD Indicates extent of TIMBER.
UPPER LEVEL PLAN
70MM int. timber frame 50 step
AFW aluminium framed window. flue flue kit SBJ silicone butt jointed glass. denotes change in level Aboda Lee Foster • director
Design p - 0424 620 247
Scott Falconer • director
p - 0431 267 157
Group e - [email protected] e - [email protected]
Indicates extent of GS DR Indicates extent CONCRETE
BA sun control battens, refer detail. GS garage slab. SP structural post, refer engineer. chs shs structural posts - refer fw
denotes floor waste the aboda design group trust
ABN 56 266 884 746
Level 2 1794 David Low Way Coolum Beach,
Q. 4573. PO box 2449 Noosa Heads Q 4567
t/a aboda design group • BSA License -150580097 • See the original
The page text is free to read. Viewing or downloading an original file needs an account.