Appendix B Code and Overlay Assessment
45 Elizabeth Street, Noosaville



 Division 9— Natural Hazards Overlays Code
 Specific outcome                                     Probable solution                            Response                                                  Complies
 Table 13.12 Acid sulfate soil areas
 13.39 Effects of works

 General

 O22 Works do not disturb acid sulfate soils or are   Partial solution S22.1 The disturbance
 managed to avoid the release of acid or associated   of acid sulfate soils is avoided by—
 metal contaminants.
                                                         a) not excavating or otherwise
                                                         removing soil or sediment identified      Excavation works are not proposed.                        YES
                                                         as containing acid sulfate soils;

                                                         b) not permanently or temporarily
                                                                                                   Excavation works are not proposed.                        YES
                                                         extracting groundwater that results
                                                         in the aeration of previously
                                                         saturated acid sulfate soils; and

                                                         c) not undertaking filling that results
                                                         in actual acid sulfate soils being        The site is proposed to be filled 900mm. This fill will   YES
                                                         moved below the watertable or             be designed and undertaken in accordance with the
                                                         previously saturated acid sulfate         relevant guidelines for working within acid sulphate
                                                         soils being aerated; OR                   soil areas.




                                                      S22.2 The disturbance of acid sulfate        Site ground works will be designed and undertaken in
                                                                                                                                                             YES
                                                      soils avoids the release of acid or          accordance with the relevant guidelines for working
                                                      associated metal contaminants by—            within acid sulphate soil areas.

                                                         a) neutralising existing acidity and


                                                                                                                                                                        132

Used in these records

About this file

File size
1.3 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

AppendixB_CodeandOverlayAssessment.pdf · 1.3 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.