Council archive · source document
Approved Plan - 51993.564.02
Plans and drawings: the text below has words only, no drawings.
Original PDF page 1, section 1. The text section number identifies this passage in the reader.
owner responsibility notes:
-it is the responsibility of the owner to provide all weather access to building site
-it is the responsibility of the owner to undertake tree removal, including obtaining associated permits, and
to provide a site clear of any vegetation
site notes: or debris to satisfaction of builder prior to commencement of site works
-position of dwelling to be confirmed by client prior to any -it is the responsibility of the owner to undertake removal of any site spoil/stock piles to the satisfaction of
site works the builder prior to commencement
-all storm water, down pipes, rain water tanks & site of building works or a variation will be incurred for associated costs
drainage to be sized & located by the hydraulic - any walls constructed on the boundary, will require the client/s
consultant/plumber in accordance with ncc vol 2 3.1.3.5 to remove the boundary fence prior to construction
& 3.5.2 and qdc mp4.2/local planning scheme house
code
-builder to ensure that actual sewer line and manhole
positions match those as shown -based on local authority
9
78
1.
documents. any discrepancies must be brought to the note: all windows and gates opening into pool enclosure to comply with pool safety requirements (all louvres
attention of builder and resolved prior to commencement max, 100mm blades) pool fencing to specialist contractors specifications - plans shown indicative only.
T1
of construction
-builder to determine appropriate platforming method on pool fencing must comply with australian standard as 1926.1 & qdc part 3.4.
site prior to commencement of any works. finished floor fencing to be minimum 1200mm high with self-closing gate as per requirements. provide resuscitation sign.
level is to be above the minimum level as per local provide pool fencing certificate(s).
authorities requirements & to comply with ncc vol 2
3.1.2.3 pool safety barriers must comply with the building act 1975, building regulation 2006, qdc mp3.4 -
-the finished surface immediately surrounding the swimming & pool barriers and australian standards as 1926.1 & as 1926.2.
buildings to comply with ncc vol2, 3.1.3.
-surface drainage is to discharge evenly within the site
and without nuisance to adjoining properties.
-all sub-floor areas must be graded to avoid the ponding
of water.
-cut and fill batters not to exceed a maximum slope as
per ncc table 3.1.1.1 for the site specific soil type, refer 231°46'10"
also to ncc clause 3.2.2.4 for slab edge support on 35.002
sloping sites.
-1000 maximum high timber retaining walls with 65∅ ag
pipe behind (to discharge to stormwater line) and
granular backfill behind, to be wholly contained within the
site only if indicated on the plans.
'0"
1°7
-the height of fences, including the height of retaining
0
.50
17
walls are not to exceed 2.0m above finished ground level,
12
only if indicated on the plans and to local authority
approval.
all proposed finished floor levels to be checked and
verified
4
on site to comply with minimum building requirements,
14
4.940
2.
5 2.140
flood levels 68
322°56'15"
2.
UNIT 2
13.501
5
and local council regulations, prior to construction NEIGHBOURING DWELLING 04
2.
25
4
2.
8
67
5,3
2.
sewerage to local council design roof water to
7
82
77
1.
discharge into rainwater tank and overflow into EXISTING 216.6 m2 7.594
existing council system 7.626 9
6.947 95
7.607 7.591 6 1.
28
2
50
3
37
6 2.
9. 6. 387
6.41
0 0 2.
0
66 43 EXISTING PARTY WALL EXISTING PARTY WALL
note: built-to-boundary allotments only - 2. 2.
150
5 6 5
612.54963
2.544 21
surveyor setout required, and certificate to be submitted 8.
1
48 7. 7.
2.
7.619
to building certifier prior to final approval. ensure no APPROVED 54
4 7.6117.6
7.61115
2.
encroachment over boundary, including gutter GAZEBO
1
43 2.543 2.551
cavity stacker
2. 4
2.162
7
70 70
14.9 m2 8. 8.
UNIT 1
224°20'5
7,783
8 "
34
note: all windows and gates opening into SUBJECT DWELLING
5 69
50 .5
1
46
2. 2.
17 17.496
pool enclosure to comply with pool safety 0
8.
19
2. 2 2. 1
requirements (all louvres max, 100mm blades) pool FF
L
fencing to specialist contractors specifications - plans 7 3
FFL:2.40 4.936 4.9
4.824
shown indicative only. 65 .6
2 9 71
7. 6.9817 6.763 2.
48 1.965 2.050
5
00
46
3 2.
7.623 54 7.585 7.574
2.
all existing sewers and easements on site
1,5
should be located prior to construction
4.902
4.5 m2
4.900
36
328°0'0"
4.679
APPROVED CARPORT
41
4
4.947 4.947 64
2.
30.5 m2
1,5
note: original detail land survey 0
2.
54
undertaken by: Cadcon 33 9
0
47 1
46
1.2 m2
2. 8
32.6
5" 5.171 2.
43
2.1 m2 2. 0
2.
48 2.
40
34'2 5.186
75°
5,18
3
37
1.982 2.062 83
1.
4
4.947 4.937 4.934
1,6
2.059
5"
5,
3
9
41
3.22
°0'4
2. 1.981
16
342
1
2 9
36 83
328°0'0"
2. 1.
6.000
2.065
2 3
39 22 1.980
2. 2.
5 3.
28 22
N 2.
2.090 10°1'2 3
0"
5
1.989 83
2.080 1.
3.223
3.838 38°1'5 6.000
5"
2.0
73 1.974
52°2'17" 52°2'55"
2.062
2
2.006 2.061 837
4
1.947 11..83
8 1.939 .843 1
82 83 T2
1.887 1.1.933 1 1. 08
7
2 1.
5 7 1
82 81
1 82
6 80 .80 8 1. 1. 1.
81 1. 1 67
1. 1.
SITE AREA SCHEDULE:
SITE AREA: 740.5m2 (total)
SITE COVER: EXISTING 222.4m2 (30.03%)
EXISTING DEMO - 5.89m2 0"
PROPOSED ADDITION 7.8m2
5'3
2°4
6 26
PROPOSED CARPORT 30.5m2 .49
29
PROPOSED GAZEBO 14.9m2
PROPOSED TOTAL 53.2m2
PROPOSED TOTAL INC. EXISTING 269.71m2 (36.4%)
hws
COUNCIL: NOOSA COUNCIL hws
NOOSA COUNCIL
APPROVED PLAN m/b
51993.564.01 27 OCTOBER See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 7 sections
Section 2
2023
0 1m 5m
Revision Proposed Residence Address Client Scale
This plan shall remain the sole property of Suncoast Building Design and must not be 1/10 Sunseeker Cl Noakes 1:200
given, lent, hired out or otherwise disposed of or copied without the written permission of Rev A - 27.06.23 - Proposed Gazebo in leiu of Alfresco
Suncoast Building Design. Rev B - 24.08.23 - Extend Living wall Noosaville
Rev C - 05.10.23 - Council RFI & Internal changes Drawn Page No.
Note: all dimensions/engineer details and relevant information to be checked and
confirmed by builder /client. Suncoast Building Design does not take any responsibility MM/SB 2
after drawings have been checked and confirmed by builder/client or construction has Suite 7 / 10 Grebe St, Peregian Beach mob: 0401565629
Document
commenced. Set ID: 22610652 [email protected] Job No. Date Stage Drawing
Version: 1, Version Date: 06/10/2023 www.suncoastbuildingdesign.com.au mob: 0491289102
20.141 05.10.23 DA Approval Site Plan
Section 3
2
3 1
4
project notes:
-
UNIT 2
NEIGHBOURING DWELLING
5,3
77
EXISTING PARTY WALL EXISTING PARTY WALL
FR BUILT IN STORAGE
EURO LDRY
0
150
KITCHEN
3,801 SITTING
GAZEBO
WALL TBC
DINING 7,776
2138 stacker
cavity stacker
ENTRY
2109
FFL:2.40
00
1,5
c LOUNGE
770
820
built wall out as PDR
required for cavity
stacker
ROBE
LINEN
CARPORT
ROBE
BED 1
2106 L 2106 L
41
770
WIR ENS
1,5
2108 GLASS
ROBE
5,12
37
0
1,6
5,
12
8
b
a
NOOSA COUNCIL
APPROVED PLAN
51993.564.01 27 OCTOBER 2023
0 1m 5m
Revision Proposed Residence Address Client Scale
This plan shall remain the sole property of Suncoast Building Design and must not be 1/10 Sunseeker Cl Noakes 1:100
given, lent, hired out or otherwise disposed of or copied without the written permission of Rev A - 27.06.23 - Proposed Gazebo in leiu of Alfresco
Suncoast Building Design. Rev B - 24.08.23 - Extend Living wall Noosaville
Rev C - 05.10.23 - Council RFI & Internal changes Drawn Page No.
Note: all dimensions/engineer details and relevant information to be checked and
confirmed by builder /client. Suncoast Building Design does not take any responsibility MM/SB 5
after drawings have been checked and confirmed by builder/client or construction has Suite 7 / 10 Grebe St, Peregian Beach mob: 0401565629
Document
commenced. Set ID: 22610652 [email protected] Job No. Date Stage Drawing
Version: 1, Version Date: 06/10/2023 www.suncoastbuildingdesign.com.au mob: 0491289102
20.141 05.10.23 DA Approval Ground Floor Plan
Section 4
UNIT 2
NEIGHBOURING DWELLING
EXISTING PARTY WALL EXISTING PARTY WALL
80
745
1,182
2,9
2,840
3,320
2,240
4,090
4,090
2138 stacker
3,100
cavity stacker
5,745
90
250
1,160
2109
5,0
00
90
c
90
1,053
900
770
820
5,380
90
5,080
90
3,740
2106 L 2106 L
2,980
2,750
770
2,230
2108
6,000
250
250
250
14,830 90 1,750 90 4,190 220
3,600 250 10,980 90 1,800 250 4,200 1,800
3,600 250 4,900 90 4,300 90 1,600 90 1,800 250 6,000
b
a
NOOSA COUNCIL
APPROVED PLAN
51993.564.01 27 OCTOBER 2023 0 1m 5m
Revision Proposed Residence Address Client Scale
This plan shall remain the sole property of Suncoast Building Design and must not be 1/10 Sunseeker Cl Noakes 1:100
given, lent, hired out or otherwise disposed of or copied without the written permission of Rev A - 27.06.23 - Proposed Gazebo in leiu of Alfresco
Suncoast Building Design. Rev B - 24.08.23 - Extend Living wall Noosaville
Rev C - 05.10.23 - Council RFI & Internal changes Drawn Page No.
Note: all dimensions/engineer details and relevant information to be checked and
confirmed by builder /client. Suncoast Building Design does not take any responsibility MM/SB 6
after drawings have been checked and confirmed by builder/client or construction has Suite 7 / 10 Grebe St, Peregian Beach mob: 0401565629
Document
commenced. Set ID: 22610652 [email protected] Job No. Date Stage Drawing
Version: 1, Version Date: 06/10/2023 www.suncoastbuildingdesign.com.au mob: 0491289102
20.141 05.10.23 DA Approval Ground Floor Dimension Plan
Section 5
2
3 1
4
project notes:
-
GAZEBO ROOF
REMOVE DOOR AND REPLACE WITH
1224 SW, INFILL GAP AND MAKE GOOD
REMOVE DECK K S
OR
DW
OSE
OP
PR
NO CARPORT ROOF
c
PROPOSED ROOF
b
a
NOOSA COUNCIL
APPROVED PLAN
51993.564.01 27 OCTOBER 2023 0 1m 5m
Revision Proposed Residence Address Client Scale
This plan shall remain the sole property of Suncoast Building Design and must not be 1/10 Sunseeker Cl Noakes 1:100
given, lent, hired out or otherwise disposed of or copied without the written permission of Rev A - 27.06.23 - Proposed Gazebo in leiu of Alfresco
Suncoast Building Design. Rev B - 24.08.23 - Extend Living wall Noosaville
Rev C - 05.10.23 - Council RFI & Internal changes Drawn Page No.
Note: all dimensions/engineer details and relevant information to be checked and
confirmed by builder /client. Suncoast Building Design does not take any responsibility MM/SB 7
after drawings have been checked and confirmed by builder/client or construction has Suite 7 / 10 Grebe St, Peregian Beach mob: 0401565629
Document
commenced. Set ID: 22610652 [email protected] Job No. Date Stage Drawing
Version: 1, Version Date: 06/10/2023 www.suncoastbuildingdesign.com.au mob: 0491289102
20.141 05.10.23 DA Approval First Floor Plan
Section 6
notes:
3.5.1.2 Corrosion protection and compatibility
requirements for roofing
(a)Metal sheet roofing must be protected from
corrosion in accordance with Table 3.5.1.1.
(b)Where different metals are used in a roofing
system, including flashings, fasteners, guttering,
downpipes, etc., they must be compatible with each
other as described in Tables 3.5.1.2a to 3.5.1.2d and
(i)no lead materials can be used upstream from
aluminium/zinc coated materials; and
(ii)no lead materials can be used on roofs that form
part of a potable (drinking) water catchment area; and
(iii)no copper materials can be used upstream from
galvanised coated materials.
3.5.3.2 Materials
Gutters, downpipes and flashings must—
(a)be manufactured in accordance with AS/NZS 2179.1
for metal; and
(b)be manufactured in accordance with AS 1273 for
UPVC components; and
(c)be compatible with all upstream roofing materials in
accordance with 3.5.1.2(b); and
(d)not contain any lead if used on a roof forming part
of a potable water catchment area.
3.5.3.4 Installation of gutters
(a)Gutters must be installed with a fall of not less than
—
(i)1:500 for eaves gutters, unless fixed to metal fascias;
and
(ii)1:100 for box gutters.
(b)Eaves gutters must be—
(i)supported by brackets securely fixed at stop ends
and at not more than 1.2 m centres; and
(ii)be capable of removing the overflow volume
specified in Table 3.5.3.3a and Table 3.5.3.3b.
20°
FAL (c)Overflow measures in accordance with Table
L 3.5.3.4a
20°
FAL 3.5.3.5 Downpipes — size and installation
L
Downpipes must—
(a)not serve more than 12 m of gutter length for each
down pipe; and
(b)be located as close as possible to valley gutters;
and
00
(c)be selected in accordance with the appropriate
1,5
eaves gutter section as shown in Table 3.5.3.2a to
c Table 3.5.3.2c.
3.5.1.3 Minimum pitches for metal sheet roofing
20° FALL profiles
2° FALL
metal roofing 5○ or more will be corrugated custom
orb uno
41
metal roofing between 2○ - 5○ will be trapezoidal
1,5
profile or similar
metal roofing at 1○ will be a concealed fastened
profile or similar
37
5,12
1,6
0
5,
12
8
b
a
NOOSA COUNCIL
APPROVED PLAN
51993.564.01 27 OCTOBER 2023 0 1m 5m
Revision Proposed Residence Address Client Scale
This plan shall remain the sole property of Suncoast Building Design and must not be 1/10 Sunseeker Cl Noakes 1:100
given, lent, hired out or otherwise disposed of or copied without the written permission of Rev A - 27.06.23 - Proposed Gazebo in leiu of Alfresco
Suncoast Building Design. Rev B - 24.08.23 - Extend Living wall Noosaville
Rev C - 05.10.23 - Council RFI & Internal changes Drawn Page No.
Note: all dimensions/engineer details and relevant information to be checked and
confirmed by builder /client. Suncoast Building Design does not take any responsibility MM/SB 8
after drawings have been checked and confirmed by builder/client or construction has Suite 7 / 10 Grebe St, Peregian Beach mob: 0401565629
Document
commenced. Set ID: 22610652 [email protected] Job No. Date Stage Drawing
Version: 1, Version Date: 06/10/2023 www.suncoastbuildingdesign.com.au mob: 0491289102
20.141 05.10.23 DA Approval Roof Plan
Section 7
notes:
wall cladding to be installed a per manufacturers
spec.
refer to job spec. for all colours/finishes
All openable windows where the floor below the
window is 2m or more above the surface beneath
& has a sill height less than 1.7m from ffl, will be
fitted with a device capable of restricting the
window opening in accordance with ncc 3.9.2.6 &
3.9.2.7
position of external lights & outlets not shown in
elevation
window sizes shown are nominal only & may vary
depending on manufactures specifications and
exact sizes
locations for all heating & cooling units, solar
panels, man holes & whirly birds and the like are
nominal only and subject to change as per final on
site location requirements by relevant supplier
FF - CL (5.100)
all barriers & hand rails to comply with ncc 3.9.2
proposed window to
replace sliding door
o/a height as per existing
FF- FL (2.700)
GF - CL (2.400)
UNIT 2
NEIGHBOURING DWELLING
GF - FL (0.000)
Elevation 1
FF - CL (5.100)
NO PROPOSED WORKS
carport
gazebo
FF- FL (2.700)
GF - CL (2.400)
3,117
3,115
2,496
2,546
GF - FL (0.000)
Elevation 2
NOOSA COUNCIL
APPROVED PLAN
51993.564.01 27 OCTOBER 2023 0 1m 5m
Revision Proposed Residence Address Client Scale
This plan shall remain the sole property of Suncoast Building Design and must not be 1/10 Sunseeker Cl Noakes 1:100
given, lent, hired out or otherwise disposed of or copied without the written permission of Rev A - 27.06.23 - Proposed Gazebo in leiu of Alfresco
Suncoast Building Design. Rev B - 24.08.23 - Extend Living wall Noosaville
Rev C - 05.10.23 - Council RFI & Internal changes Drawn Page No.
Note: all dimensions/engineer details and relevant information to be checked and
confirmed by builder /client. Suncoast Building Design does not take any responsibility MM/SB 9
after drawings have been checked and confirmed by builder/client or construction has Suite 7 / 10 Grebe St, Peregian Beach mob: 0401565629
Document
commenced. Set ID: 22610652 [email protected] Job No. Date Stage Drawing
eVersion:
l e v 1,a Version
t i o nDate:
s 06/10/2023 www.suncoastbuildingdesign.com.au mob: 0491289102
20.141 05.10.23 DA Approval Elevations
Section 8
notes:
wall cladding to be installed a per manufacturers
spec.
refer to job spec. for all colours/finishes
All openable windows where the floor below the
window is 2m or more above the surface beneath
& has a sill height less than 1.7m from ffl, will be
fitted with a device capable of restricting the
window opening in accordance with ncc 3.9.2.6 &
3.9.2.7
position of external lights & outlets not shown in
elevation
window sizes shown are nominal only & may vary
depending on manufactures specifications and
exact sizes
locations for all heating & cooling units, solar
FF - CL (5.100) panels, man holes & whirly birds and the like are
nominal only and subject to change as per final on
site location requirements by relevant supplier
all barriers & hand rails to comply with ncc 3.9.2
NO PROPOSED WORKS
carport
FF- FL (2.700)
GF - CL (2.400)
approx. form n.g.l
3,227
3,040
3,117
UNIT 2
NEIGHBOURING DWELLING
GF - FL (0.000)
Elevation 3
NOOSA COUNCIL
APPROVED PLAN
51993.564.01 27 OCTOBER 2023 0 1m 5m
Revision Proposed Residence Address Client Scale
This plan shall remain the sole property of Suncoast Building Design and must not be 1/10 Sunseeker Cl Noakes 1:100
given, lent, hired out or otherwise disposed of or copied without the written permission of Rev A - 27.06.23 - Proposed Gazebo in leiu of Alfresco
Suncoast Building Design. Rev B - 24.08.23 - Extend Living wall Noosaville
Rev C - 05.10.23 - Council RFI & Internal changes Drawn Page No.
Note: all dimensions/engineer details and relevant information to be checked and
confirmed by builder /client. Suncoast Building Design does not take any responsibility MM/SB 10
after drawings have been checked and confirmed by builder/client or construction has Suite 7 / 10 Grebe St, Peregian Beach mob: 0401565629
Document
commenced. Set ID: 22610652 [email protected] Job No. Date Stage Drawing
Version: 1, Version Date: 06/10/2023 www.suncoastbuildingdesign.com.au mob: 0491289102
20.141 05.10.23 DA Approval Elevations
Used in these records
Approved Plan - 51993.564.02.pdfRelated documentApplication case desk ↗
About this file
- File size
- 445 KB (small file)
- File type
No other editions are linked here.