                                          Building Suncoast Green

   column 1                               column 2
    Specific                 Probable solutions (if code assessable)
   Outcomes
                             b)    Use toughened glass, security screens
                                   and other measures (but not including
                                   security shutters that obscure the view
                                   of shop fronts) are used in windows
                                   which are provided at ground level, to
                                   deter break and enters; and
                             c)    Use hardy vandal proof materials
                                   and anti-graffiti paint are used in
O28 Lighting of                    the construction of buildings.
appropriate intensities                                                         Complies – Electrical
                             S28.1 Lighting of appropriate intensities is
is provided to                                                                  contractors will install lighting
                              provided which satisfies the requirements of
maximise safety.                                                                which meets Australian
                              Australian Standard AS1158: Public
                              Lighting Code, unless otherwise specified in      Standard AS1158: Public
                              this Code;                                        Lighting Code, unless
                                                                                otherwise specified in this
                             AND                                                Code;
                             S28.2 External lighting of a graduated
                             intensity is provided which starts at a lower      Complies – The lighting design
                             level of brightness at the perimeter of the        achieves the solution.
                             site and rises to a higher level at the
                             entrance to buildings or at the centre of the
                             site;
                             AND
                             S28.3 Lighting is directed onto the site and       Complies - Lighting spill has
                             away from neighbouring properties;                 been considered and will be
                                                                                operated at acceptable levels
                             AND
                                                                                and will not impact adjoining
                             S28.4 Vandal-resistant lighting is used in         properties.
O29 Public toilets are       public and publicly accessible areas.
designed and constructed     S29.1 Public toilets are located in high           Complies - The lighting design
to—                          traffic areas;                                     achieves the solution.
a)    ensure the safety of
      all people using       AND
      them; and              S29.2 Features that may legitimise                 N/A
b)    take advantage         loitering, such as seating or public
      of informal            telephones are not located within 20m of
      surveillance from      toilet entrances;                                  N/A
      adjoining uses
      and activities,        AND
      discouraging           S29.3 Entrances to public toilets are              N/A
      non-legitimate         visible from the street, footpath and other
      uses.                  activity areas on the site or adjoining
                             sites.

                             S30.1 Safe and convenient pathway access           Complies - A public bus stop is
O30 Premises have            is provided from the site to link to existing      located on Eumundi Noosa Road
accessibility to public      pathway networks that services public              approximately 500m from the
transport.                   transport facilities;                              subject site.
                             OR
                             S30.2 Direct pathway access is provided to         Complies - A paved footpath
                             the public transport facility if the facility is   along Gateway Drive and
                             contained on site or within 50m from the           Eumundi Noosa Road links the
                             property boundary.                                 subject site to the bus stop.




                                                                                                              23
Log in to download the original file

5. Planning Report.pdf · 1.4 MB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.