Original source · versioned page text
Bushfire Report
Attached to the e-mail MCU16/0081 Bushfire report, Survey, Ecological Assessment Report Email 2 of 3.
Original PDF page 93, section 1. The text section number identifies this passage in the reader.
FURTHER READING
Ahern A., Aon Re Worldwide and
Chladil M. (2004). How Far do
Bushfires Penetrate Urban Areas?
Tasmania Fire Service.
Blanchi, R., Leonard, J. and Maughan,
D. (2004). Towards New Information
Tools for Understanding Bushfire
Risk at the Urban Interface. CSIRO
Manufacturing & Infrastructure
Technology, Bushfire Research,
Bushfire CRC Research Project.
Chen, K. and McAneney, J. (2004).
Quantifying Bushfire Penetration
Into Urban Areas in Australia. Risk
Frontiers–Natural Hazards Research
Centre, Macquarie University, NSW,
Australia, June.
Leonard, J. (2003). Bushfires in
the ACT. Australian Institute of
Building Surveyors 38th Annual State
Conference.
McAneney, J and Chen, K. (2010)
Bushfire Penetration Into Urban
Areas in Australia: A Spatial
Analysis, Bushfire CRC report for
the 2009 Victorian Bushfires Royal
Commission. Researcher Justin Leonard examines a fence after burning test at the NSW Rural Fire Service Hot Fire
Training Facility.
when flames did not contact the fencing until ignition of the fencing occurred, after The results, when used alone, should only be
systems, however they provided little barrier which point additional heat impact was used for research and development, quality
during direct flame contact. Neither fencing received by all elements behind the fencing. assurance or similar industrial needs. More
configuration supported lateral flame spread Significant risk of house loss occurred during extensive toxic release experiments could be
to the extent that would expose the structure all experimental exposures, either through conducted to simulate fencing exposure to
to direct flame contact. Under structural thermal exposure or mechanical impact as bushfire for a quantitative risk assessment of:
fire exposure conditions, the fencing the fencing collapsed onto the structure. the toxic gases released during combustion
quickly burnt away leaving no barrier to the Under structural fire exposure conditions, the of each fencing material; the impact of air
impinging flames. fencing quickly burnt away leaving no barrier emissions of arsenic; the exposure of site
to the impinging flames and radiant heat. occupants to arsenic from the ash from
Treated pine
CCA-treated pine, and; the contamination of
This had the worst performance, as its FUTURE DIRECTIONS
building sites from arsenic.
integrity under leaf litter attack resulted in The cone calorimeter experimental method
ignition and extensive flame spread with the used for toxic release does not assess the fire Detailed analysis is needed of the fencing data
potential for loss of the adjacent structure. hazard of the materials – or products made collected by the Bushfire CRC Task Force after
Its performance as a heat barrier was good from them – under actual fire conditions. Black Saturday.
Fire Note is published jointly by the Bushfire Cooperative Research Centre Australasian Fire and Emergency Service
Bushfire Cooperative Research Centre Level 5/340 Albert Street Authorities Council
(Bushfire CRC) and the Australasian Fire East Melbourne VIC 3002 Level 5/340 Albert Street
and Emergency Service Authorities Council Telephone: 03 9412 9600 East Melbourne VIC 3002
(AFAC). This Fire Note is prepared from www.bushfirecrc.com Telephone: 03 9418 2388
available research at the time of publication www.afac.com.au
to encourage discussion and debate. The Bushfire CRC is a national research centre in the
contents of the Fire Note do not necessarily Cooperative Research Centre (CRC) program, formed AFAC is the peak representative body for fire,
represent the views, policies, practices or in partnership with fire and land management agencies emergency services and land management agencies
positions of any of the individual agencies in 2003 to undertake end-user focused research. in the Australasia region. It was established in 1993
or organisations who are stakeholders of the Bushfire CRC Limited ABN: 71 103 943 755 and has 26 full and 10 affiliate members.
Bushfire CRC.
4 Background briefings on emerging issues for fire managers from AFAC and Bushfire CRC.