DRAWING SIZE — At

 

 

 

 

SLAB AS DETAILED

 

   

 

 

 

PAVEMENT AS

 

 

 

 

 

 

KE

CONSTRUCTION NOTES
GENERAL:

 

 

 

HEIGHT DATUM IN STRUCTURAL DETAILED ON DRG EX. SWPT EXISTING STORMWATER PIT 1. DO NOT SCALE FROM THIS DRAWING.
DOCUMENTS 33082-0W3.2 EX. SMH EXISTING SEWER MANHOLE 2. ALL DIMENSIONS IN MILLIMETRES
LOT 159 ON RP 48112 FFL AS EX. SCP EXISTING SEWER CONNECTION POINT 3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE
Level Datum AHD Y w NOMINATED. E.0.B. EXISTING EDCE OF BITUMEN ARCHITECTURAL DRAWINGS.
Level Origin PSM 99159 ye — K & C EXISTING KERB & CHANNEL 4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE
Elanda St, Sunshine Beach Y/ LPL AS a NS.L. NATURAL SURFACE LEVEL ARCHITECTURAL DRAWINGS ARE TO BE REFERRED TO THE
Yo NOMINATED FH, FIRE HYDRANT ENGINEER IMMEDIATELY.
Survey information provided by . 3 TP TELSTRA PIT 5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING
ARNOLD DEVELOPMENT CONSULTANTS = EP. ELECTRICAL PILLAR SERVICES WITHIN AND ADJACENT THE ALLOTMENT AND SHALL
CLL LE i KERB EXISTING KERBING ENSURE THAT ALL NEW WORKS ARE IN ACCORDANCE WITH
LL LL RCEW REINFORCED CONCRETE END WALL THE ATTACHED CRITICAL DEPTH LINE DIAGRAM.
SV STOP VALVE
WM WATER NETER FILLING NOTES

 

  

—THE SITE IS TO BE SCRAPED CLEAR OF ALL ORGANIC
MATERIAL AND DEBRIS.

—THE SUBGRADE IS TO BE ROLLED WITH A VIBRATING STEEL
DRUM ROLLER TO ACHIEVE A MINIMUM RELATIVE FIELD
DENSITY OF 98%. THE COMPACTION IS TO BE SUFFICIENT TO
ACHIEVE A BLOW COUNT OF 7 BLOWS PER 300mm WITH AN
APPROVED PERTH SAND PENETROMETER FOR A DEPTH OF
1.0m BELOW EXCAVATED LEVEL. COPIES OF COMPACTION TEST
RESULTS SHALL BE PRESENTED TO SCG CONSULTING
ENGINEERS FOR APPROVAL.

—UNLESS NOTED OTHERWISE A MINIMUM BEARING CAPACITY
OF 100kPa SHOULD BE ACHIEVED WITHIN COMPACTED FILLING.
COMPACTION & BEARING CAPACITY TEST RESULTS MUST BE
PRESENTED TO SCG CONSULTING ENGINEERS FOR APPROVAL
PRIOR TO WORKS PROCEEDING.

—THE FILL MATERIAL CLEAN GRANULAR MATERIAL (I.E. SAND
TO A CLAYEY SAND IN ACCORDANCE WITH AS1726) BE FREE
OF ANY ORGANIC MATERIAL AND HAVE A CLAY CONTENT OF
LESS THAN 12% (PLASTICITY INDEX LESS THAN 25%, LINEAR
SHRINKAGE OF 15%). THE PROPOSED MATERIAL IS TO BE
INSPECTED BY SCG CONSULTING ENGINEERS PRIOR TO ITS
REMOVAL TO ENSURE ITS COMPATIBILITY.

—THE FILL IS TO BE PLACED AND COMPACTED IN
ACCORDANCE WITH AS3798-1996 TO A LEVEL SUFFICIENT TO
ACHIEVE A LEVEL 2 CERTIFICATION WITH A MINIMUM RELATIVE
FIELD DENSITY OF 98%. COPIES OF COMPACTION TEST
RESULTS SHALL BE PRESENTED TO SCG CONSULTING
ENGINEERS FOR APPROVAL.

FILLING AND COMPACTING ADJACENT EXISTING STRUCTURES
IS TO BE IN STRICT ACCORDANCE WITH THE ASSOCIATED
DETAILS AND SPECIFICATIONS.

—AREAS WHERE EXISTING STRUCTURES OR TREES ARE
REMOVED SHALL BE BACKFILLED WITH THE APPROVED FILL
MATERIAL COMPACTED IN ACCORDANCE WITH AS2870-1996 TO
ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 987.

—ANY LOOSE OR SOFT MATERIAL UNCOVERED IN THE SITE
PREPARATION SHALL BE REMOVED AND REPLACED WITH THE
APPROVED FILL MATERIAL COMPACTED IN ACCORDANCE WITH
AS2870-1996 TO ACHIEVE A MINIMUM RELATIVE FIELD
DENSITY OF 98%.

—SITE DRAINAGE AND SILT PROTECTION MEASURES MUST BE
ISTALLED PRIOR TO CONSTRUCTION COMMENCING.

ya

 

 

DRIVEWAY /CARPARK PAVEMENT

FINISHED LEVELS DIAGRAM
TYPICAL SECTION

IS TX, FOOTING AS
DETAILED IN
STRUCTURAL

DOCUMENTS

 

 

TEMPORARY CFA PILED RETAINING WALLS BUILDING PAD

— CFA PILED RETAINING WALL DESIGN AND INSTALLATION
BY A SPECIALIST CONTRACTOR

— DRIVING OF PILE WALLS NOT PERMITTED

— INSTALLATION OF GROUND ANCHORS INTO NEIGHBORING
PROPERTIES NOT PERMITTED WITHOUT OWNERS CONSENT
— ADDITIONAL MEASURES SUCH AS GROUTING THE JOINTS
IS RECOMMENDED TO REDUCE GROUNDWATER INFLOWS.

— PROVIDE GROUND MONITORING/VIBRATION CONTROL
DURING INSTALLATION.

— ESTABLISH SURVEY MONITORING POINTS ALONG PILED
WALL TO MONITOR WALL ALIGNMENT/ GROUND MOVEMENT

 

MINOR RESHAPING TO EX. GROUND
LEVELS IN ROAD RESERVE FOR NEW
DRIVEWAY. ENSURE MIN. COVER TO
SERVICES ARE MAINTAINED AND
RE-TURF. MAX. PERMANENT CUT
BATTERS 1:3 V:H TYPICAL.

 

ESTABLISH SURVEY MOITORING POINTS ALONG PILE WALL
CAPPING BEAM TQ MONITOR WALL ALIGNMENT/GROUND

     
    
    
 
 
       
  

EXISTING UNITYWATER SEWER
MANHOLE TO BE LOWERED OR
DECOMISSIONED TO NEW DRIVEWAY
LEVELS TO FUTURE DETAIL IN
ACCORDANCE WITH UNITYWATER
APPROVAL.

MOVEMENT, PILING CONTRACTORS ENGINEER TO BE ADVISED OF on
ANY OBSERVED MOVEMENT x

 

 

 

) ENSURE 600mm MIN. BEHIND
D PILING TO ALLOW FOR
ACCESS FOR BASEMENT
WALL WATERPROOFING.
TYPICAL.

 

   
 

ESTABLISH SURVEY MOITORING POINTS ALONG PILE WALL
CAPPING BEAM TO MONITOR WALL ALIGNMENT/GROUND
MOVEMENT, PILING CONTRACTORS ENGINEER TO BE ADVISED OF
ANY OBSERVED MOVEMENT

 

 

 

—, 90.60

 

0.034 -1.434

 

L9' BL
Z2CS BV
\

0.309

 

 

 

~——

—
Pay

IM»

 

-2.227
TEMPORARY BATTERED
EMBANKMENT FOR
BASEMENT EXCAVATIONS.
MAX. SLOPE 1V: 2H, IN
ACCORDANCE WITH
GEOTECHNICAL ENGINEER
RECCOMENDATIONS.

y

 

 

REFER Drg 33082-0W4.1
FOR DRIVE WAY DETAILS.

  
   
 
  

BUILDER TO POT HOLE LOCATE AND
CONFIRM EXISTING SERVICES LOCATIONS
& LEVELS BEFORE ANY EARTHWORKS
ARE CARRIED OUT. REPORT ANY
DISCREPANCIES TO THIS FIRM.

T

600mm _ MIN.

POOL
EXCAVATION

   
 
   

7] BASEMENT
FFL: 49.210

FPL: 48.960

y

 

 

 

LL°8v

7

 

GROUND
FPL: 91.600

EXISTING STRUCTURE /OWELLING
INCLUDING NEIGHBOURING
ALLOTMENTS

 

THE BUILDER/CONTRACTOR
SHALL CONFIRM ALL
RELEVANT LEVELS PRIOR 10
COMMENCING WORKS.

 

 

|

C2062)

 

 

FLANDA Sl

Ground /

 

Ne

 

pad Tevel
UNSTABLE
Yy

 

 

 

 

 

 

LEGEND

--~~ INDICATES PROPOSED SURFACE
CONTOURS AND LEVELS TO AHD. ae

THIS FOOTING WITHOUT
t+ PIERS IS FOUNDED

ABOVE CRITICAL DEPTH

LINE AND IS UNSTABLE.

 

 

 

 

 

-0.106 -2.915

 

 

THIS FOOTING IS FOUNDED

BELOW CRITICAL DEPTH
LINE AND IS STABLE.

 

48.07

 

 

 

EXISTING SURFACE SPOT LEVELS.

 

 

4480

LINE OF PROPOSED
PIERS OR UNDERPINNING FOUNDED 1B —*— EXCAVATION OR OTHER
BELOW THE CRITICAL DEPTH LINE Ne TRENCH.

WOULD BE NEEDED TO SUPPORT

ANY FOOTING THAT IS FOUNDED
ABOVE THE CRITICAL DEPTH LINE.

 

DASHED LINE INDICATES
PROPOSED BUILDING

INDICATES DEPTH OF CUT (NEGATIVE) OR : AX FOOTPRINT

FILL (POSITIVE) AS NOTED A

 

 

 

Horizontal 30 Degrees’

CRITICAL DEPTH LINE

 

ono

 

>

NOTE:

THIS DETAIL ALSO APPLIES TO EXISTING
FOUNDATIONS ON NEIGHBOURING
PROPERTIES. SHEET PILING MUST BE
INSTALLED WHERE EXISTING FOOTINGS WILL
BE FOUNDED ABOVE ANY EXCAVATION
CRITICAL DEPTH LINE

Sy NR

aN \
INDICATES CFA

 

 

 

2 6Y

»
y

INDICATES AREA OF CUT

OS

 

EXTENT OF PILING TO BE DETERMINED IN
ACCORDANCE WITH CRITICAL DEPTH LINE
PROTECTION OF NEIGHBOURING STRUCTURES

CONCRETE PILING OR SIMILAR, DESIGN AND
INSTALLATION BY OTHERS. MINIMUM VIBRATION TECHNIQUES TO
BE USED FOR INSTALLATION, VIBRATION CONTROL AND
MANAGEMENT BY PILING CONTRACTOR. BUILDER TO CONFIRM
EXTENT REQUIRED TO SATISFY CRITICAL DEPTH LINE
PROTECTION OF NEIGHBOURING STRUCTURES.

 

 

 

INDICATES AREA OF FILL

 

Elevations Table

RC CAPPING BEAM

INDICATES POSITION OF TEMPORARY FULL LGTH OF WALL

Minimum Elevation Maximum Elevation Color

 

 

    

  

 

 

 

    

 

  
  

 

 

 

 

 

   

 

 

 

   
 

 

 

 

BED SHORING, DESIGN AND INSTALLATION BY REFER DETAIL. RC CONTIG PILES,
SPECIALIST CONTRACTOR i ot
DESIGN BY OTHERS EXISTING GROUND LEVEL
—_ v
——  E —— INDICATES OVERHEAD ELECTRICITY \
SUPPLY LINE ©
INDICATES EXISTING SEWER LINE I Ti Tk Revision Description Date
eet Issue:
HT =
— w—— _INDICATES WATER MAIN APPROX Ei: | FOR APPROVAL
ALIGNMENT, BUILDER TO CONFIRM EXACT Tel 2
LOCATION PRIOR TO WORKS SITE PLAN — EARTHWORKS & PILING PLAN =vcAATON DEPT Ful |5 DO NOT SCALE FROM THIS DRAWING
INDICATES TELSTRA LINE APPROX Scale 1: 100 Vv a The design and associated details contained on this and associated
T ———— TWATEIA a drawings are copyright and are not to be used or reproduced without
vOCAHON PROR- Ig Works EXACT TF Toi n the written permission of SCG Consulting Engineers.
DILAPIDATION REPORT: 5
SITE_GEOTECHNICAL 4 f
BUILDER TO MAINTAIN STABILITY —E—er—EeereroJrm" PRIOR TO ANY CONSTRUCTION = Unit 1/11 Project Ave,
— sw/ex INDICATES STORMWATER DRAIN EXISTING OF ALL NEIGHBOURING STRUCTURES, INFORMATION RECOMMENDATIONS PRESENTED IN UNDERTAKE DILAPIDATION REPORT OF ALL = SCG Noosa Heads
NEIGHBORING DWELLINGS/ STRUCTURES. el
AS NOTED RIS EET oe UNE OETAL COMPLETED BY A GEOTECHNICAL ENGINEER. f Fe e\ cm ean
5 ‘WweD:www.Scg-engineers.com
RW INDICATES POSITION OF CONCRETE i meee
SLEEPER RETAINING WALL TO a Tith
— — = itle:
STRUCTURAL ENGINERS DETAIL. PRIOR TO COMMENCING WORKS, ALL SERVICES SHOWN ON THIS PLAN INDICATIVE NOTE: CONTRACTOR TO REPAIR ADJACENT THE Tel EARTHWORKS PLAN
UNDERTAKE DILAPIDATION REPORTS OF ONLY CONTRACTOR TO LOCATE ALL SERVICES CONSTRUCTION SITE KERB, FOOTPATH OR MITE

CUT/FILL LEVELS SHOWN REPRESENT THE FINISHED PAD
LEVEL (FPL) TO THE UNDERSIDE OF THE GROUND BEARING
SLABS AND PAVEMENTS AND INCLUDES THE CRUSHER

PRIOR TO COMMENCING WORKS ON SITE. ALL ROAD RESERVE IF ANY DAMAGE IS SUSTAINED

 

 

ALL NEIGHBORING DWELLINGS/STRUCTURES (OR CONCRETE PILED RETAINING WALL

 

SERVICES ARE TO BE PROTECTED IN DURING CONSTRUCTION. GRASSED AREAS ARE

 

 

 

ACCORDANCE WITH THE AUTHORITY
RESPONSIBLE FOR THE SERVICE

TO BE RE TOP SOILED AND TURFED.

 

www.dialbeforeyoudig.com.au

\_/ SECTION Project

56 ELANDA ST,
SUNSHINE BEACH

 

 

DUST OR ROAD BASE LAYERS 10 BE PROVIDED UNDER THE
SLABS. ADDITIONAL LANDSCAPING FILL NOT INCLUDED.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BEFORE YOU DIG Date: May 3 Drawn Design 1H
om __ > * ‘mt:100@a1 § noes a va Ne. .
wn 200 @ AB : eRehardeon | 199082 —OW2.1} -

 

 

 

Used in these records

About this file

File size
4.1 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

OPW23_0139 - Appendix B - Engineering Plans.pdf · 4.1 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.