Original source · versioned page text
Approved Plan - OPW26 0021 (As Published)
Plans and drawings: the text below has words only, no drawings.
LEGEND
MARK DESCRIPTION
CADASTRAL PARCELS
W
S EXISTING BUILDING
N
EXISTING SEWER MAIN S ROADWORKS & CARPARKING
W
EXISTING CONCRETE
S
ELECTRICAL
W
S POLES
S PILLARS
W
E(OH) E(OH)
LINE NETWORK HV (OH)
S E(OH) E(OH)
LINE NETWORK LV (OH)
W
11KV HIGH VOLTAGE CABLE (UG)
MH
S
LOW VOLTAGE CABLE (UG)
EXISTING SINGLE WATER
GARAGE TO REMAIN
W .33 EXISTING SYSTEM VALVE
~3 FH
S
W EXISTING HYDRANT (FH)
W EXISTING WATER MAIN
PP
S
SEWER
W
EXISTING MAINTENANCE HOLE (MH)
S
EXISTING DRIVEWAY EXISTING MAINTENANCE SHAFT (MS)
W
W
H)
AND CROSSOVER TO EXISTING SEWER MAIN
S S
S
E(O
REMAIN
COMMUNICATIONS
S
W
W
NBN EXISTING COMMUNICATIONS
S
H)
STORMWATER
S
E(O
EXISTING SINGLE CAR W S
W
EXISTING STORMWATER PIPE
S
SW
PORT TO REMAIN
W
MH
S EXISTING STORMWATER SURFACE FLOW
S
)
W
H
S
LEVELS & RETAINING
E(O
W
0
3.0 EXISTING RETAINING WALL
S
S
MH
S
W
0 + 23.750 EXISTING SURFACE LEVEL
2.1
W
H)
S
E(O
DU
W S
W
K
6.7
ES
S
T
0
W S
E
) H
RE
TR
E(O
FH
W
ST
EE
W
S
ER
T
S
W
P P
H)
DE
S
E(O
S
W
W
S EXISTING CONCRETE
S
W
DRIVEWAY STRIPS TO
W
H)
)
OH
E(O
S BE REMOVED
E(
PP
S
S
W
H)
W
S
S
E(O
W
PP S
)
OH
W
W
S
E(
S
H)
S
E(O
)
OH
S
W
E(
S
S
NOOSA COUNCIL
EXISTING SITE LAYOUT APPROVED PLAN
OPW26/0021 3 MARCH 2026
SCALE 1:200 @ A3
255104-OPW-01-260121.DWG
SCALE APPROVAL ISSUE DATE DESCRIPTION BY CHKD DRAWING DETAILS PROJECT NUMBER
PROJECT CLIENT 1 21-01-26 FOR APPROVAL DK DK
PROPOSED DRIVEWAY CROSSOVER LAWRENCE REID 0 2 4 6 8 10m
.................
DATUM
DESIGN
AHD
DK
255104
8 DUKE STREET SUNSHINE BEACH
DANIEL KENNA DRAWN DK SHEET ISSUE
TITLE SCALE 1:200 A3 (RPEQ 15522)
EXISTING SITE LAYOUT PLAN
e [email protected] ABN 99 642 485 363 This drawing is not to be copied or amended without written permission from DRAWING STATUS DESIGN CHECK DK C03 1
Document Set ID: 24527658 a PO Box 988 Maroochydore 4558 p 0404 157 187 Ingeniir Pty Ltd FOR APPROVAL DATE 21-01-26
Version: 1, Version Date: 10/02/2026
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 1 page
Page 2
S LEGEND
N
W
MARK DESCRIPTION
MH
S
CADASTRAL PARCELS
PROPOSED BUILDING
W
ROADWORKS & CARPARKING
S
PROPOSED DRIVEWAY/CARPARK
W
PROPOSED CROSSOVER
S
PROPOSED NEW KERB
W
CCJ CONTROL JOINT
SLAB CUT JOINT
S
SJ
W
ELECTRICAL
POLES
S
W
PILLARS
H)
E(OH) E(OH)
LINE NETWORK HV (OH)
S
E(O
W
W
E(OH) E(OH)
LINE NETWORK LV (OH)
W 11KV HIGH VOLTAGE CABLE (UG)
S
H)
W
DU
LOW VOLTAGE CABLE (UG)
E(O
W
0
3.0 WATER
KE
S
S
MH
S
W EXISTING SYSTEM VALVE
ST
FH
W
0
3.5
H)
S
RE
EXISTING HYDRANT (FH)
E(O
+ FSL 41.65
ET
MATCH INTO EXISTING W S W EXISTING WATER MAIN
W
LEVELS AT BOUNDARY. SEWER
4.
9
S
1.4
2%
NEW DRIVEWAY TO MIDDLE W
4
S
H)
OF EXISTING GATE FSL EXISTING MAINTENANCE HOLE (MH)
E(O
FH +
W
5
W 1.4 EXISTING MAINTENANCE SHAFT (MS)
L4
S
2.
FS
5%
4
S + EXISTING SEWER MAIN
S S
2.1
W
H)
LEVELS & RETAINING
S
E(O
6.7
S + INV 41.30
W
1.5
0
W + FSL 23.750 PROPOSED FINISHED SURFACE LEVEL
0
S
NEW CROSSOVER TO
S
W
W
IPWEAQ STD DRGS.
H)
E(O
S
RSD-100 & RSD-101
S
S (RS-049 & RS-050)
W
NT
H)
POI
W
S
S
E(O
ON
SITI
W
RAN
PP TO
T T
EE
S
)
.24
OH
~15
W
W
TR
S
E(
S S
ER
H)
P
S
E(O
)
EP
OH
S
W
3.5
E(
S D 3.0
S
~15
)
W
OH
PROPOSED SITE LAYOUT
MAINTAIN 1m CLEARANCE FROM CROSSOVERS .24
E(
TO POWER POLES, PRAM RAMPS, KERB LINTELS 6.70
AND OTHER OBSTRUCTIONS TYPICAL
1.5m
| 2.5% SCALE 1:200 @ A3
1.5m
CROSSOVER AS PER
| 12.5
%
IPWEAQ STD DRGS RSD-100
& RSD-101 TYPICAL
N
R PLA
FOOTPATH AS REQ'D AS PE
AS PER IPWEAQ STD NOOSA COUNCIL
DRG PCD-101 APPROVED PLAN
OPW26/0021 3 MARCH 2026 EXISTING CROSSOVER DETAILS
TYPICAL CROSSOVER DETAILS
255104-OPW-01-260121.DWG
SCALE APPROVAL ISSUE DATE DESCRIPTION BY CHKD DRAWING DETAILS PROJECT NUMBER
PROJECT CLIENT 1 21-01-26 FOR APPROVAL DK DK
PROPOSED DRIVEWAY CROSSOVER LAWRENCE REID 0 2 4 6 8 10m
.................
DATUM
DESIGN
AHD
DK
255104
8 DUKE STREET SUNSHINE BEACH
DANIEL KENNA DRAWN DK SHEET ISSUE
TITLE SCALE 1:200 A3 (RPEQ 15522)
PROPOSED SITE LAYOUT PLAN
e [email protected] ABN 99 642 485 363 This drawing is not to be copied or amended without written permission from DRAWING STATUS DESIGN CHECK DK C04 1
Document Set ID: 24527658 a PO Box 988 Maroochydore 4558 p 0404 157 187 Ingeniir Pty Ltd FOR APPROVAL DATE 21-01-26
Version: 1, Version Date: 10/02/2026