Council archive · source document
Approved Plans & Compiled Reference Documents - MCU19 0008.02 · MCU19/0008.02
Plans and drawings: the text below has words only, no drawings.
Very large file (10.9 MB): may take a few minutes to open.
Attachment F: City Plan policy – Geotechnical stability assessment
Appendix 1: Landslide susceptibility analysis form
LANDSLIDE SUSCEPTIBILITY ANALYSIS Analysis No. PG-2096-01
Location: Site No. Site Name:
1 Natural Surface Slope 9 Material in cutting
Site Level Factor Site Level Factor
Less than 5 degrees L 0.1 High strength rock L 0.5
0.5 Between 5 and 15 degrees M 0.5 Medium strength rock L 1
Between 15 and 30 degrees M 0.8 Low strength rock M 1.2
Between 30 and 45 degrees H 1.2 Very low strength rock and soil H 1.5
More than 45 degrees M 0.8 2 Soil VH 2
2 Slope Shape 10 Cut slope support
Site Level Factor Site Level Factor
Crest or ridge L 0.7 0.5 Concrete wall L 0.5
0.9 Planar / Convex M 0.9 Crib wall M 0.9
Rough / Irregular H 1.2 Gabion wall M 1
Concave H 1.5 Rock wall H 1.5
3 Site geology Unsupported H 2
Site Level Factor
Volcanic Extrusive rock H 1.1 11 Concentration of surface water
Sedimentary rock M 1 Site Level Factor
1 Low grade metamorphic rock M 1 Ridge L 0.7
High grade metamorphic rock L 0.9 Crest M 0.8
Volcanic Intrusive rock M 1 0.9 Upper slope M 0.9
4 Soils Mid slope H 1.2
Site Level Factor Lower slope H 1.5
Rock at surface VL 0.1 12 Wastewater Disposal
Residual soil < 1m deep L 0.5 Site Level Factor
Residual soil 1-3m deep M 0.9 1 Fully Sewered M 1
1.5 Residual soil > 3m deep H 1.5 Onsite disposal – Surface M 1.2
Colluvial soil < 1m deep H 1.5 Onsite disposal – Soak Pit/Trenches H 1.5
Colluvial soil 1-3m deep VH 2
Colluvial soil > 3m deep VH 4 13 Stormwater Disposal
5 Fill height Site Level Factor
Site Level Factor All stormwater piped into road drainage L 0.7
None L 1.0 1 Rain water tank with overflows M 1
1.1 Less than 1m M 1.1 Stormwater discharge on site H 1.5
Between 1 and 3m M 1.3
Between 3 and 6m H 1.7 14 Evidence of instability
More than 6m VH 2.5 Site Level Factor
6 Evidence of groundwater 0.8 No sign of instability L 0.8
Site Level Factor Soil Creep H 1.2
0.7 None apparent L 0.7 Minor irregularity VH 2
Minor moistness M 0.9 Major irregularity VH 5
Generally wet H 1.5 Active instability VH 10
Surface springs VH 3
Summary
7 Cut height Factor
Site Level Factor 1 Natural Surface Slope M 0.5
None (Go to section 11) L 1.0. 2 Slope Shape M 0.9
Less than 1m M 1.1 3 Site Geology M 1
Between 1 and 3m M 1.3 4 Soils H 1.5
1.7 Between 3 and 6m H 1.7 5 Fill Height M 1.1
More than 6m VH 2.5 6 Evidence of Groundwater L 0.7
7 Cut height H 1.7
8 Slope of cut face 8 Slope of Cut Face L 0.5
Site Level Factor 9 Material in Cutting VH 2
0.5 Less than 30 degrees L 0.5 10 Cut Slope Support L 0.5
Between 30 and 45 degrees M 1 11 Concentration of Surface Water M 0.9
Between 45 and 60 degrees H 1.5 12 Wastewater Disposal M 1
More than 60 degrees VH 3 13 Stormwater Disposal M 1
14 Evidence of Instability L 0.8
Relative Susceptibility (1x2x3x4x5x6x7x8x9x10x11x12x13x14) 0.32
Low
Major update to City Plan Policies (Schedule 6) – Draft for Adoption Page 8 of 11
Word Version (#60957630) PDF (#68702182)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plans & Compiled Reference Documents - MCU19 0008.02.pdfRelated documentApplication case desk ↗
About this file
- File size
- 10.9 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.