9
Job No. ME13/018
All footings should found within medium dense sand, beneath the loose surficial
sand and below the expected zone of erosion by wind, rainfall and surface runoff.
Structural design should ensure stiffness in the down slope direction e.g. Strip
footings and internal beams aligned up and down the slope.
No structural development is to found within loose surficial soils, or shallower than
1.0m or on non structural or uncontrolled fill material.
6.0 GENERAL GUIDELINES FOR DEVELOPMENT
Sound hillside engineering practice is essential to the long term performance of the
development.
The proposed residential development must be designed, constructed and maintained in
accordance with the attached Guidelines for Hillside Construction and the development
examples shown on the attached Illustrations of Good and Poor Hillside practice. The more
significant requirements are summarized below:
. No cut or fill should be carried out unless approved by a suitably qualified
geotechnical engineer or engineering geologist. All fill should be constructed under
Level One Supervision as defined in AS 3798 2007 (Guidelines on Earthworks For
-
Commercial and Residential Developments)
. All storage tank overflow water must be piped to the nearest gully well down slope of
the proposed houses or into the stormwater system. Uncontrolled discharge to the
hill slope is not permitted.
. Storage tanks should be located down slope or to the side of the proposed house.
. No development should take place within any surface irregularities such as possible
slumped areas, washouts or erosion features. If development is to occur in these
areas, surface irregularities must be removed prior to development and drainage
improved.
If the recommendations outlined in Sections 5.0 to 7.0 are followed and implemented the risk
level implications for the risk posed to the property can be reduced to Low which is a tolerable
level of risk.
Ref 01273 - Mr Andrew Aitken
Lot 9 No. 18 Tropicana Rise, Castaways Beach. MORRISON GEOTECHNIC
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
REFERENCED DOCUMENT - MCU13/0106Related documentApplication case desk ↗
REFERENCED DOCUMENT - MCU13/0106Related documentApplication case desk ↗
About this file
- File size
- 16.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.