Approved Plans - 132002.220270.3

of 3

Page text read automatically using OCR, there may be inaccuracies

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
SUNSHINE COAST REGIONAL COUNCIL

        APPROVED
132002.220270.3       12 NOV 12


[OCR of page images]
 

 

EXISTING ROOF

|

   

 

JOINERY

EXISTING ROOF

EXISTING ROOF

QW NL/]/00,_,_/L_L_7_, FTY~“

 

PURLINS

 

 

PAINTED PBD SHEETING
WITH COVER BATTENS
FIXED TO TIMBER
FRAME WALLS

MEZZANINE RL 2.44

 

WINDOWS FIXED TO
MANUFACTURER'S SPEC

   

ALUMINIUM FRAMED

 

 

 

 

 

 

 

 

JOINERY

 

  

 

 

 

90 x 90 HWD.
TIMBER POST

TIMBER FRAMED
STAIRS FIXED TO
MANUFACTURER'S SPEC

EX. SLAB RL 0.00

    
   
  

75 MIN

ELEVATION A

SCALE 1:100

 

  
   
   

YELLOWTONGUE PLY

 
 
    
 

EXISTING OVER 140x45mm F27
WORKSHOP/ EXISTING CONCRETE HWD FLOOR JOISTS.
WALLS & SLAB BATTEN SCREW FLOOR
STORAGE JOISTS TO POLE PLATE

AND BEAM

 

 

 

MEZZANINE RL 2.44

MEZZANINE/OFFICE

 

ALUMINIUM FRAMED
WINDOWS FIXED TO
MANUFACTURER'S SPEC.

PAINTED PBD SHEETING
<—— WITH COVER BATTENS
FIXED TO TIMBER
FRAME WALLS

 

 

 

 
 
   
 
 
 
  

140x45mm F27 HWD
POLE PLATE FIXED TO
EXISTING WALL VIA
2/M12 BOLTS (TYPICAL)

 
 
 
 
   
    

EXISTING CONCRETE
WALLS & SLAB

 

 

4

 

EX. SLAB RL 0.00

|

90x90mm HWD POST

HOT DIP GALVANISED
BRACKET EITHER SIDE OF
<——— POST WITH 2/M12 BOLTS

FIX BRACKET TO EX. CONCRETE
SLAB VIA 2/M12 BOLTS

 

UZ LTCTTTTTaa——_———> es,

y

200x63mm SMARTFRAME LVL.
BEAM FIXED TO EXISTING WALL.
VIA GALVANISED BRACKET
EITHER END. 2/M12 BOLTS EACH
TO BEAM AND WALL

EXISTING
WORKSHOP/
STORAGE

DETAIL SECTION

 

 

~

NOTES:

STAIRS TO COMPLY WITH BCA D2.9 AND D2.13.
BALUSTRADES AND HANDRAILS TO
COMPLY WITH D2.16 AND D2.17.

N3

STRUCTURAL DESIGN BASED UPON
NON-CYCLONIC N3 FOR WIND SPEEDS
TO 41 mis.

TERMITE PROTECTION:
AS PER AUSTRALIAN STANDARD AS3660.1/2000

HATCHINGS AND FITTINGS ARE
INDICATIVE ONLY.

 

 

NOTE:

LEVELS ARE ON AN ARBITRARY DATUM.
LEVELS & DIMENSIONS FOR EXISTING
STRUCTURE TO BE VERIFIED ON SITE.
BO NOT SCALE.

 

 

 

 

 

 

NOTE:
ALL OPENING SIZES ARE TO BE
CONFIRMED ON SITE BY CONTRACTOR.

 

 

 

 

 

 

 

 

 

 

 

SCALE 1:50
/oi\ POST FOOTING DETAIL
Ye) SCALE 1:20 SUNSHINE COAST REGIONAL COUNCIL
APPROVED
132002.220270.3 12 NOV 12
Amendments: Proposed Additions WORKING DRAWING

General Notes:

These drawings have been prepared for Building Permit application only. It is the Builders/owners responsibility to
further interpret the design and drawings to detail the project for construction.

The builder shall verify the location of all services.

All levels and dimensions are to be checked and verified by the builder on site prior to the commencement of any
work, making of shop drawings or fabrication of components.

DO NOT SCALE OFF DRAWINGS.

USE FIGURED DIMENSIONS.

 

 

To Existing Unit at

 

 

Lot 2 on SP 189445

 

for GMS Corp Pty Ltd

2/61 Gateway Dve, Noosaville

 

ELEVATION & SECTION
DETAILS

 

Scale: As Shown @ A3 Date: 27/9/10

Drawn: JL

 

 

 

Signed:

 

 

Revision:

 

Sheet: 3 “)

 

 

 

 
Log in to download the original file

APPROVED PLANS - 132002.220270.3.pdf · 1.1 MB (small file)