Original source · versioned page text
Revised 8256 Eumundi Noosa Road TENDER ISSUE electronically signed 2024-04-11
CH 46.150
CH 75.040
CH 90.000
CH 0.000
TYPE 2 RETAINING WALL TYPE 1 RETAINING WALL TYPE 2 RETAINING WALL
END OF EXISTING
CARPARK WALL CH 46.875
100mm STEP IN TOP OF WALL
100mm STEP IN TOP OF WALL
100mm STEP IN TOP OF WALL
100mm STEP IN TOP OF WALL
WEST EXTENT OF WALL
100mm STEP IN TOP OF WALL
NORTH-WEST CORNER
EAST EXTENT OF WALL
NORTH-EAST CORNER
NEW CONCRETE BLOCK
RETAINING WALL
CH10
CH35
007
007
CH55
CH77
CH85
EARTHWORKS FINISHED
007
007
007
SURFACE BEHIND WALL
200mm STEP IN TOP OF FOOTING
200mm STEP IN TOP OF FOOTING
200mm STEP IN TOP OF FOOTING
200mm STEP IN TOP OF FOOTING
200mm STEP IN TOP OF FOOTING
200mm STEP IN TOP OF FOOTING
FOOTING
500mm STEP IN TOP OF
900mm STEP IN TOP OF FOOTING
FOOTING
200mm STEP IN TOP OF
EXISTING SEWER
EXISTING (SURVEY)
MIN. 600mm
COVER TO
SURFACE
EARTHWORKS IN FRONT OF WALL EARTHWORKS IN FRONT OF WALL
TOE OF EXISTING (NORTHERN FACE) TO BE (NORTHERN FACE) TO BE
RETAINING WALL BACKFILLED WHERE EXISTING BACKFILLED TO MATCH EXISTING
IN NEIGHBOURING WALL RETURN IS REMOVED. REFER SURFACE PROFILE BEHIND
PROPERTY EARTHWORKS PLAN FOR DETAILS. EXISTING TIMBER SLEEPER WALL.
EXISTING TIMBER B
SLEEPER WALL
ALONG EDGE OF
EXISTING RETAINING WALL (PARALLEL TO NEW WALL) TO BE RETAINED EXISTING RETAINING WALL TO BE TAKEN UP AND REPLACED WITH CARPARK TO
NEW WALL ON NEW ALIGNMENT BE RETAINED
DATUM RL 4.0
TOP OF WALL RL 20.160 RL 20.060 RL 19.960 RL 19.860 RL 19.760 RL 19.660
RL RL 19.560 RL 19.360 RL 19.160 RL 18.960 RL 19.160 RL 18.260 RL 18.760 RL 18.960 RL 19.160
TOP OF FOOTING 19.760
0.40m 0.60m 0.80m 1.00m 0.90m 1.10m 0.90m 0.80m 1.70m 1.60m 1.10m 0.90m 0.80m 0.70m 0.50m
WALL HEIGHT
TOE OF B
19.320
19.155
18.754
18.365
17.942
17.641
17.056
16.924
16.843
EXISTING WALL
EXISTING
19.844
19.760
19.556
19.360
19.236
19.072
19.096
19.039
19.243
19.469
19.393
19.471
19.388
19.156
19.003
19.002
18.960
19.296
SURFACE
14.500
20.000
23.500
25.244
31.500
40.000
46.150
60.000
75.038
77.400
80.000
81.784
81.984
86.600
90.000
CHAINAGE
0.000
2.500
8.500
RETAINING WALL ELEVATION
HORIZONTAL SCALE 1:200
NOTES
1. REFER TO DRG 8256-005 OR RETAINING WALL LAYOUT
AND LOCATION.
2. REFER TO DRGS 8256-010 TO 012 FOR RETAINING WALL
STRUCTURAL DETAILS AND SPECIFICATION.
0 2 4 6 8 10m
SCALE 1:200 ( A1 SIZE)
TENDER ISSUE
© Black & More Client Drawing Title
This document is and shall remain
Black & More
ABN 19 609 960 232
BDH GROUP INVESTMENTS
the property of Black & More. Project
170-174 EUMUNDI-NOOSA ROAD REDEVELOPMENT
Revisions
This document may only be used
for the purposes for which it was
ATHERTON | CAIRNS | NOOSA |
NORTH LAKES | TOOWOOMBA
RETAINING WALL ELEVATION
commissioned and in accordance Drawn Drawing Approved Date 11/04/2024
B UPDATED TENDER ISSUE PM PM 11/04/24 with the Terms of Engagement for Telephone (07) 4031 9944 WM Check PM/JB Original signed by
Telephone (07) 5447 4444
A ISSUED FOR TENDER PM PM 10/04/24
the commission. Unauthorised use
P. Mathers RPEQ
6954
Drawing Size Scale (A1 size) Drg No Revision
No. Description Reviewed Approved Date
of this document in any form
whatsoever is prohibited.
Email
Internet
[email protected]
www.blackm.com
Designed Design
KMK/JB Check PM/JB Drawing is not to be used for construction unless approved A1 1:200 8256-007 B
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file