Attach K- Code Compliance Tables

Attached to the e-mail MCU16/0012 - 5 Garnet Street Cooroy.

of 25

Page text shows just the words. Original shows the document exactly as it was published.

                                                                                      town planning
                                                                              code compliance tables
Planning Scheme Code Compliance Tables
    Business Uses Code
Specific outcomes, probable solutions and acceptable solutions for the Business Uses Code

 Table 14-8 For all Business Uses
 Specific Outcomes                                     Probable Solutions                                     Compliance
 14.16 Effects of use
 Electricity infrastructure                            S18.1 No solution provided                             Complies- the proposal will not impact on
 O18 The development does not adversely impact         S19.1 Development for uses adjacent to or within       existing or future electricity supply infrastructure.
 on existing or future electricity supply              50m of an existing electricity substation
 infrastructure;                                       incorporates noise attenuation measures to
                                                       mitigate noise impacts;
 AND                                                   AND
 O19 All uses and works maintain an adequate safe      S19.2 Buildings and structures (including swimming     Complies- the proposed building will not
 distance from electrical infrastructure including     pools, sheds, tennis courts and outbuildings) are      impinge on safe distance from electrical
 substations, overhead powerlines, power poles         not constructed under overhead electricity             infrastructure.
 and transformers.                                     transmission lines, or within electricity easements.
 Noise                                                 No solution provided                                   Complies – the site is located within the Business
 O20 Development is designed and sited to avoid                                                               Centre zone and will not lead to noise emissions
 noise emissions that unreasonably diminish the                                                               that diminish the amenity of the surrounding
 amenity of the area or surrounding uses.                                                                     area.

 Mechanical plant and equipment and storage            S21.1 Mechanical plant and equipment are—              Able to be conditioned to comply- in the main
 areas                                                 a) located more than 2m from any property              plant and equipment is located within the
 O21 Mechanical plant and equipment (including         boundary;                                              basement and is therefore not visible external to
 air conditioning equipment) and storage areas are     b) where located at ground level, screened by          the site.
 designed and located to—                              fencing 1.5m in height or dense vegetation of at



   saunders havill group                                                          page 1                                                                   Job 7588
Log in to download the original file

Attach K- Code Compliance Tables.pdf · 341 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.