Appendix C - Effluent Disposal Report · MCU26/0099
Advanced Enviro-Septic Design Calculator V11.0 MULTI-BED©
MINIMUM DAILY FLOW 1,200 Lpd
AES The World Leader in Passive Solutions ©
Site Address 267 Louis Bazzo Drive, Pomona State QLD Post Code 4568
Client Name R. Wilks Date of Site Visit 16/4/2026
Designers Designers Ph Designer Lic
W R Holmes Australian Soil Investigations 0428 310 453 1120066
Name Number (e.gQBCC)
Plumber Ph Plumb / Drainer
Lic Plumber TBA TBA TBA
Number Lic Number
Designers AES
Council Area Noosa 25 Date 14/9/2026
Cert Number
Calculator is a guide only, receiving soil classification, surface water, water tables and all other site constraints addressed by qualified designer
System Designers site and soil calculation data entry IMPORTANT NOTES
Enter AES L/m pipe loading rate "38" Secondary 38 >> This design is for SECONDARY
Is this a new installation Y or N Y >> Minimun single vent size is 80mm or 2x50mm house vents
Number of AES BEDS 1 >> Input the number of AES Beds 1 to 4
Number of Bedrooms 3 >> Not used in ANY Calculation. If not known 0 or leave blank.
Number of persons 5 >> Septic outlet filter NOT RECOMMENDED GRAVITY Systems
Daily Design FLOW Allowance Litre/Person/Day 120
Minimum AES Pipe Daily Flow (GOVERNMENT REGULATED) L/Day 1200 >> Government Requirement
Number of AES Pipe ROWS required per BED 4 >> Longer AES runs are better than multiplule short runs.
Infiltration Soil Category from site/soil evaluation per AS/NZS1547 5 >> Catagory may require design considerations. Refer AS1547
Design Loading Rate based on site & soil evaluation DLR (mm/day) 8 >> Soil conditioning may be necessary. Refer AS1547
Soil Bore log depth 2.0m >> Check water table, restrictive layers, etc
Is this design a GRAVITY system with no outlet filter? Y or N Y >> GRAVITY. House Vent & LOW VENT on AES bed is required
PLEASE CHECK YOU HAVE FALL FROM TANK TO AES SYSTEM PIPES 75
COMMENTS :- " The outcome must be important to everyone. "
- Ripping receiving surface is required in clay soil structures Cat 4,5,6. Refer to AS 1547. Always excavate & rip parallel to the site slope/AES pipe.
- Specialist soils advice & design techniques will be required for clay dominated soil having dispersive or shrink/swell behaviour. Refer AS1547
- Designers need to be familar with special requirements of Local Authorities (Minimum falls from Septic tank outlets to Land application areas etc
- Good construction techniques as per AS1547 are especially important in these soil types. Refer AS1547 & AES installation Instructions
1200
AES System Calculator Outcomes AES dimensions For ONE Bed
AES System System Extension
Total System load - litres / day (Q). 600 l/d
Length:(L) 9.60m 9.60m
7.89 Min Length of AES pipe rows to treat loading 7.89 lm
Width:(W) 2.25m 5.56m
Number of FULL AES Pipe lengths per row 3 lths
Sand Depth
Total Capacity of AES System pipe in Litres 2544 ltr. 0.75m 0.15m
:
AES Additional infiltration extension required 53.4 m2 Area m2 21.6 m^2 53.4 m^2
USE CUT LENGTHS OF PIPE IN THIS DESIGN? (ENTER Y)
IF YOU WISH TO USE A TRENCH EXTENSION DESIGN OPTION ENTER "Y" Enter Custom Width in metre
AES INFILTRATION FOOT PRINT AREA - L = Q / ( DLR x W) Length Width Minimum AES foot print required
AES Bed 1 9.60m x 7.81m = 75.0 m2 per AES Bed
OVERALL AES TOTAL FOOTPRINT 9.60m x 7.81m = 75.0 m2 TOTAL
AES pipes are best centered in the trench parallel to the site slope
Code AES System Bill of Materials. Chankar Environmental Use Only
AES-PIPE AES 3 metre Lengths required 12 lths
AESC AES Couplings required 8 ea
AESO AES Offset adaptors 8 ea
AESODV AES Oxygen demand vent 1 ea
“Nature's Wastewater Solutions”
AESODV AES Oxygen demand vent EXTRA MULTI BEDS 1 ea
AES-IPB AES 100mm Inspection point base 2 ea
TD Kit 4 4 Hole Distribution Box Kit 1 ea
Digitally signed by Kane Dickson
TD Kit 7 7 Hole Distribution Box Kit ea DN: cn=Kane Dickson, o=Chankar
VS43-4 Sweet Air Filter VS43-4 ea Environmental Pty Ltd ,
ou=Advanced Enviro-Septic ,
AES DESO Double Offset Adaptors ea
email=designreview@enviro-
TOTAL SYSTEM SAND REQUIRED (Estimate Only) 29 m3 septic.com.au, c=AU
Date: 2026.09.14 13:38:14 +10'00'
Please email your AES Calculator (EXCEL FORMAT), Site Layout & AES Design to
[email protected] [email protected]
> The AES Calculator is a design guide ONLY to allow checking of the AES components and BED configuration.
> Site and soil conditions referencing AS1547 are calculated and designed by a Qualified Wastewater Designer.
> Chankar Environmental accepts no responsibility for the soil evaluation, loading calculations or DLR entered by the designer for this calculator.
> AES pipes can be cut to length on site. They are supplied in 3 meter lengths only.
> AES ONLY supply AES components as detailed in the above Bill of Materials.
> SEPTIC Tank & other components including APPROVED SAND will need to be sourced from other suppliers. Refer to www.enviro-septic.com.au .
AES-Design-V11.0-Multi-bed Calculator © Copy Right - Chankar Environmental Pty Ltd 15/2/2024 Ph: 07 5474 4055
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix C - Effluent Disposal Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.