                                               Advanced Enviro-Septic Design Calculator V11.0 MULTI-BED©
                                                                 MINIMUM DAILY FLOW 1,200 Lpd
                                        AES The World Leader in Passive Solutions ©
 Site Address 267 Louis Bazzo Drive, Pomona                                                                        State        QLD              Post Code                 4568

 Client Name R. Wilks                                                                                                                        Date of Site Visit       16/4/2026

  Designers                                                                              Designers Ph                                          Designer Lic
                W R Holmes Australian Soil Investigations                                                          0428 310 453                                           1120066
   Name                                                                                    Number                                              (e.gQBCC)
                                                                                         Plumber Ph                                           Plumb / Drainer
 Lic Plumber TBA                                                                                                       TBA                                                 TBA
                                                                                           Number                                              Lic Number
                                                                                        Designers AES
Council Area Noosa                                                                                                         25                      Date               14/9/2026
                                                                                         Cert Number

                  Calculator is a guide only, receiving soil classification, surface water, water tables and all other site constraints addressed by qualified designer

                         System Designers site and soil calculation data entry                                                     IMPORTANT NOTES

                              Enter AES L/m pipe loading rate "38" Secondary                  38          >> This design is for SECONDARY

                                               Is this a new installation   Y or N            Y           >> Minimun single vent size is 80mm or 2x50mm house vents

                                                           Number of AES BEDS                  1          >> Input the number of AES Beds 1 to 4

                                                            Number of Bedrooms                 3          >> Not used in ANY Calculation. If not known 0 or leave blank.

                                                               Number of persons               5          >> Septic outlet filter NOT RECOMMENDED GRAVITY Systems

                               Daily Design FLOW Allowance Litre/Person/Day                  120

        Minimum AES Pipe Daily Flow (GOVERNMENT REGULATED) L/Day                             1200         >> Government Requirement

                              Number of AES Pipe ROWS required per BED                         4          >> Longer AES runs are better than multiplule short runs.

              Infiltration Soil Category from site/soil evaluation per AS/NZS1547              5          >> Catagory may require design considerations. Refer AS1547

              Design Loading Rate based on site & soil evaluation DLR (mm/day)                 8          >> Soil conditioning may be necessary. Refer AS1547

                                                               Soil Bore log depth           2.0m         >> Check water table, restrictive layers, etc

                 Is this design a GRAVITY system with no outlet filter? Y or N                Y           >> GRAVITY. House Vent & LOW VENT on AES bed is required

PLEASE CHECK YOU HAVE FALL FROM TANK TO AES SYSTEM PIPES                                             75

COMMENTS :- " The outcome must be important to everyone. "

- Ripping receiving surface is required in clay soil structures Cat 4,5,6. Refer to AS 1547. Always excavate & rip parallel to the site slope/AES pipe.
- Specialist soils advice & design techniques will be required for clay dominated soil having dispersive or shrink/swell behaviour. Refer AS1547
- Designers need to be familar with special requirements of Local Authorities (Minimum falls from Septic tank outlets to Land application areas etc
- Good construction techniques as per AS1547 are especially important in these soil types. Refer AS1547 & AES installation Instructions
         1200
                                  AES System Calculator Outcomes                                                                          AES dimensions For ONE Bed

                                                                                                                                              AES System           System Extension
                                              Total System load - litres / day (Q).          600          l/d
                                                                                                                                Length:(L)         9.60m                   9.60m
     7.89                          Min Length of AES pipe rows to treat loading              7.89         lm
                                                                                                                                Width:(W)          2.25m                   5.56m
                                       Number of FULL AES Pipe lengths per row                 3          lths
                                                                                                                                Sand Depth
                                    Total Capacity of AES System pipe in Litres              2544         ltr.                                     0.75m                   0.15m
                                                                                                                                     :
                           AES Additional infiltration extension required                    53.4         m2                     Area m2         21.6 m^2              53.4 m^2

                 USE CUT LENGTHS OF PIPE IN THIS DESIGN? (ENTER Y)

                  IF YOU WISH TO USE A TRENCH EXTENSION DESIGN OPTION ENTER "Y"                                                 Enter Custom Width in metre

   AES INFILTRATION FOOT PRINT AREA -                   L = Q / ( DLR x W)                 Length                 Width               Minimum AES foot print required
                                                                        AES Bed 1           9.60m           x      7.81m              =             75.0          m2 per AES Bed




                                  OVERALL AES TOTAL FOOTPRINT                               9.60m           x      7.81m              =             75.0          m2 TOTAL
 AES pipes are best centered in the trench parallel to the site slope

    Code                            AES System Bill of Materials.                                                                         Chankar Environmental Use Only
AES-PIPE                        AES 3 metre Lengths required                                  12          lths

AESC                                AES Couplings required                                     8          ea

AESO                                  AES Offset adaptors                                      8          ea

AESODV                             AES Oxygen demand vent                                      1          ea
                                                                                                                                             “Nature's Wastewater Solutions”
AESODV               AES Oxygen demand vent EXTRA MULTI BEDS                                   1          ea

AES-IPB                       AES 100mm Inspection point base                                  2          ea

TD Kit 4                          4 Hole Distribution Box Kit                                  1          ea
                                                                                                                                 Digitally signed by Kane Dickson
TD Kit 7                          7 Hole Distribution Box Kit                                             ea                     DN: cn=Kane Dickson, o=Chankar
VS43-4                              Sweet Air Filter VS43-4                                               ea                     Environmental Pty Ltd ,
                                                                                                                                 ou=Advanced Enviro-Septic ,
AES DESO                            Double Offset Adaptors                                                ea
                                                                                                                                 email=designreview@enviro-
                TOTAL SYSTEM SAND REQUIRED (Estimate Only)                                    29          m3                     septic.com.au, c=AU
                                                                                                                                 Date: 2026.09.14 13:38:14 +10'00'
      Please email your AES Calculator (EXCEL FORMAT), Site Layout & AES Design to
                                  [email protected]                                                                      [email protected]
> The AES Calculator is a design guide ONLY to allow checking of the AES components and BED configuration.
> Site and soil conditions referencing AS1547 are calculated and designed by a Qualified Wastewater Designer.
> Chankar Environmental accepts no responsibility for the soil evaluation, loading calculations or DLR entered by the designer for this calculator.
> AES pipes can be cut to length on site. They are supplied in 3 meter lengths only.
> AES ONLY supply AES components as detailed in the above Bill of Materials.
> SEPTIC Tank & other components including APPROVED SAND will need to be sourced from other suppliers. Refer to www.enviro-septic.com.au .
                               AES-Design-V11.0-Multi-bed Calculator ©                Copy Right - Chankar Environmental Pty Ltd 15/2/2024 Ph: 07 5474 4055

Used in these records

About this file

File size
2.2 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Appendix C - Effluent Disposal Report.pdf · 2.2 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.