Council archive · source document
Attach A - proposed upper floor · MCU15/0038
Attached to the e-mail MCU15/0038 & OPW15/0072 Response to Information request - Email 1 of 2.
NOTES: 168 noosa parade, noosa heads 8115 10 of 10 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN DOMESTIC BUILDING CODE. 2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010 (south-west) elevation D 70 100 RESIDENTIAL TIMBER FRAMING MANUAL. 100 2000 3680 2075 100 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12 10 of 10 1830 1830 elevation C 4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM (north-west) JOINT GROUP J2. 5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4. 6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF. SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH AS 1684.2 2010 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS. relocate window to here existing existing 100 8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES 100 9. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILS 100 wc AND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS 920 store (tiles) 10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO office 2020 2040 RESPONSIBILITY WILL BE TAKEN AFTER CONSTRUCTION HAS COMMENCED line of carport (carpet) 100 11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN (carpet) 900 STANDARDS RELATING TO HIS OR HER OWN WORK 820 12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 3660.1.2000 2220 100 90 line of lower floor 820csd 1100 DN office 1600 100 (carpet) hall 100 3220 copier (carpet) 1600 cabinet 4080 90 820csd balcony 820csd office office 2000 (timber) (carpet) (timber) 200 1821FG 200 fixed glass in place of glass bricks elevation A elevation B (north-east) (south-east) 100 2200 100 2000 90 3435 200 10 of 10 09 of 10 FEATURE TIMBER PINE BATTEN SCREENING proposed upper floor FG 1800 2200 FG FG FG FG FEATURE TIMBER BATTENS PROPOSED ENTRY concept drawings only FIXED TO MASONARY WALL not for construction elevation A (south-east) FEATURE HWD CLADDING TO VISUALLY ENHANCE MAIN STRUCTURE (REFER ELEVATION) PROPOSED: CLIENT: BUILDER: MANDY'S DESIGN & DRAFTING SHEET: 9 of 10 DATE: ISSUE NO: OFFICE LAYOUT DOWLING & NEYLAN TBC PH: 0403 481 474 SCALE: 1:100 JUNE 15 I NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attach A - proposed upper floor.pdfRelated documentApplication case desk ↗
About this file
- File size
- 97 KB (small file)
- File type
No other editions are linked here.