Original source · versioned page text
Architecturals
Original PDF page 16, section 1. The text section number identifies this passage in the reader.
Existing brick / tile
structured units.
BOUNDARY
BOUNDARY
Gable roof.
Boundary 10.0m height limit Boundary (wall / floor
Setback Setback
Eave location indicative)
fixed timber sun rid
shading / privacy RL ge
13
metal roofing screening between .12
RL 12.550 colorbond finish 8.0m height limit
buildings
U17, U18, U19
gu
Ceiling RL tter
11.
render. 90
paint finish. U18
FFL 9.850 walkway kitchen living balcony
U17, U18, U19
units beyond.
U13
FFL 6.850 walkway kitchen living
U10, U11, U12, U13
terrace
FFL 6.400
U14
FFL 6.050
U6, U7, U8, U9, contiguouse
U15, U16 gate piling wall as
Sidoni Stair 03
per eng. spec.
FFL 3.850 Street access path
Parking
DU4, DU5
FFL 3.050 landscaping
DU1, DU2, DU3
FFL 2.800
C1 ex. path Ex. sewer stormwater SCG Levels at
(indicative) water tanks this section
New Sewer beyond
(indicative)
Section B
metal roofing
colorbond finish
timber privacy
screen
10.0m height limit
render. metal cladding
Boundary Boundary
Setback paint finish. colorbond finish Setback
Eave
metal cladding
BOUNDARY
metal roofing
colorbond finish
BOUNDARY
colorbond finish Existing brick /
render. 8.0m height limit tile structured
paint finish.
RL 12.550 units. Gable roof.
U17, U18, U19 (wall location
Ceiling indicative).
Elevation beyond.
contiguouse
ridge
piling wall RL 10.70
beyond as per
FFL 9.850 eng. spec.
U17, U18, U19 gutter
RL 9.43
FFL 6.850
U10, U11, U12, U13
FFL 6.400
U14
FFL 6.050
U6, U7, U8, U9, gate
U15, U16 existing
path Stair 04 Existing sewer
Existing sewer connect to
FFL 3.850 access path
removed new SMH.
DU4, DU5
FFL 3.050 Existing SMH
DU1, DU2, DU3 removed
FFL 2.800 New SMH as
C1
per eng. spec. SCG Levels at
Ex. sewer pipe IL 3.41m bolt connection Existing and New SMH and New Sewer pipe New SMH as
from SCG engineers removable stair / landing this section pipe locations / size shown as per eng. spec. per eng. spec.
New pipe
nom. IL 2.19m Section C site plan & ex. services.
(drg no. 33094-C1.1)
for easement purposes indicative.
Subject to U.W.Approvals
po box 603 noosa heads qld 4567 project issue date details drawing proj no.
Mixed use development
ph 07 5455 4808
P1 25/07/2023 Pre Lodgement schematic design
2305
email [email protected]
abn 85 114 469 395 A 27/10/2023 Planning Application
reg no 002195 23 - 25 Sidoni Street Tewantin 0 1 2 3 5
B 29/02/2024 Revised Planning Application Sections dwg no.
client
B, C
Scale 1 : 100 @ A1
This drawing is subject to copyright and cannot
SD 4.03 B
be reproduced in any medium without the written
permission of Tim Ditchfield Architects Take 11 Holdings Ltd Pty Ltd
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original (Architecturals.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.