Council archive · source document
Proposal Plans · MCU22/0016.01
Plans and drawings: the text below has words only, no drawings.
Original PDF page 11, section 1. The text section number identifies this passage in the reader.
G F E D C B A
FSC TD CS REN CS AFW AFW REN CS hood AFW REN CS FC AFW hood TS
flue
W31 W18 W20 AFW
MASTER BED TIM
T.O.W R.L 17.180
UPPER STUDY
W23
W22
W08 W07 W05
FFL 15.910 ASD
FFL 15.910
UPPER LEVEL UPPER LEVEL
W11 W10
AFW COURTYARD
T.O.W R.L 14.830 FORMAL LIVING
T.O.W R.L 14.525
TS REN BLK MEDIA
FFL R.L 13.790
FRONT
AL W34 AL W33
COURT
FFL 12.970 W32 FFL 12.970
MAIN LEVEL DPx2 DP MAIN LEVEL
ASD CRAFT TS
REN BLK
PF ZAC'S REN BLK BATH ROOM
ROOM
FFL 10.770 EXISTING POOL FFL 10.770
acrylic pool window A/C A/C
LOWER LEVEL 3 LOWER LEVEL
2
FFL R.L 10.070
T.O.W R.L 9.410 5
6
1
NORTH ELEVATION
4 SCALE 1:100 @ A3
FSC BLK
BA/C1 For Buliding Approval & construction
issue issue / amendment
22.02.23 LF AB JH
EXT. FINISHES LEGEND FCA fibre cement awning. PF compliant pool fencing
issue date
client
drawn by
Ingrid & Nick Hutton
AS aluminium screen. FC fibre cement ext. cladding. PW parapet wall.
project
AL aluminium louvres, refer sched. FG fascia gutter. PS patio slab. Hutton Plover St
location
aluminium sliding door. floor tile (no refers to type). photovoltaic cells. 24 Plover St Peregian Beach
NORTH ELEVATION 3D
ASD FT1 PV
AFD aluminium framed door. fire fireplace RWT rain water tank. NORTH ELEVATION
SCALE N.T.S. AFW aluminium framed window. flue flue kit SBJ silicone butt jointed glass. Aboda Lee Foster • director Scott Falconer • director
Design p - 0424 620 247 p - 0431 267 157
Group e - [email protected]
BA sun control battens, refer detail. GS garage slab. SP structural post, refer engineer. the aboda design group trust
e - [email protected]
Level 2 1794 David Low Way Coolum Beach,
ABN 56 266 884 746 Q. 4573. PO box 2449 Noosa Heads Q 4567
BAL1 balustrade-(no refers to type). HWS hot water service. SF structural footing, ref. eng. t/a aboda design group • BSA License -150580097 • www.aboda.com.au
• This drawing is to be read in conjunction with engineers drawings & reports • Construction
BLK masonry blockwork. HR handrail. TIM timber cladding. to comply with all relevant SAA & NCC Codes & standard Bldg By-law 1975 & as amended •
Copyright for design & drawings remain the property of the authors • Verify all dimensions on
site prior to commencement of any works • These drawings are not to be used for scaling.
C carpet LPG LPG gas bottle. TD timber deck.
scale as shown @ A3 issue
CS concrete slab. NGL NRG board
TF timber floor. drawing no.
BA/
DP
DS
down pipe.
driveway slab.
MR1
NGL
metal roof - (no refers to type).
natural ground line.
TFD
VER
timber framed door
vergola.
WD.501 C1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Proposal Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 7.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.