Council archive · source document
Development Application part 9 of 10 Business Code - MCU13/0092
~
Place ba;code hec< lil~I~~lfll~~i~I~~~I~I~lr (0
80668154
.
._
_
THIS IS THE NEXT PART OF A
,0, MULTIPLE PART RECORD
\-
Part_g_ofE
Application number: MW\ 3/ OO=]2
C:\Documents and Settings\eje\Desktop\Multi Part Record Cover Sheet NEXT PART (3).doc
180X:Q.$..\93R: ..J.._O....~’-4 .
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 5 pages
Page 2
F
Atachment
[OCR of page images]
Attachment
=
Page 3
0) Table 14-8 For all Business Uses
o
t::~ column 1 column 2
Ql~
Specific Outcomes Probable solutions (if code assessable)
Q~ 14.16’ Effects cof use’", ""
,
.~~~~:~":! ’
if. iii!
,~ ~d.s ~:t ’>i C’f~
i"
,
X ,i. f -
~. f~’ ,.;
Ql.2
C’I)~ Electricity infrastructure
05; 018 The development does not adversely 518.1 No solution provided
o.g impact on existing or future electricity supply
<:5; infrastructure;
E
Q) CU
Ol
AND
~I 019 All uses and works maintain an adequate
519.1 Development for uses adjacent to or
safe distance from electrical infrastructure
within 50m of an existing electricity substation
including substations, overhead powerlines, incorporates noise attenuation measures to
power poles and transformers. mitigate noise impacts;
AND
519.2 Buildings and structures (including
swimming pools, sheds, tennis courts and
outbuildings) are not constructed under
overhead electricity transmission lines, or
within electricity easements.
Noise
020 Development is designed and sited to avoid No solution provided
noise emissions that unreasonably diminish the
amenity of the area or surrounding uses.
Mechanical plant and equipment and storage
areas
021 Mechanical plant and equipment (including 521.1 Mechanical plant and equipment are-
air conditioning equipment) and storage areas are a) located more than 2m from any property
designed and located to- boundary;
a) avoid adverse visual impacts when viewed b) where located at ground level, screened
from the street and adjoining properties; and by fencing 1.5m in height or dense
b) visually integrate with the building design. vegetation of at least 1.5m in width
incorporating grouped trees and shrubs
with maximum separation distance of 1 m
measured from the centre of the tree or
scrub; and
c) are visually integrated into the line and
plane of the building and roof design and
do not project beyond the height or width
of the building when viewed from the
street and adjoining properties;
AND
521.2 Fer Industrial business and Retail
business Type 3, materials stored outside of
a building do not exceed 4m in height or half
the height of the on-site buildings whichever is
the greater.
Safety and security
022 All property boundaries are clearly 522.1 Boundaries are identified by such
identifiable with public and private spaces clearly means as-
defined.
a) fencing; or
_Q) changes in surface l!1aterials or levels;
or
c) landscape treatments;
14-14
Business Uses Code
Page 4
column 1 column 2 ’"
o
Specific Outcomes Probable solutions (if code assessable)
c::~
AND (ti~
522.2 Loading and storage areas are well lit or a:~ .....
can be locked after hours. (ti.E
CI),:’!
023 All premises and access routes are clearly 523.1 All premises are identified by the o ~
identifiable to all persons, particularly emergency
provision of the street number in a prominent O.g
services personnel. location, preferably near the site entry, (i.e. on
<~
E
the kerb or letterbox or by signage on the (l) <11
Ol
building or site). ~~
024 All building entries are designed to be 524.1 The number of entrances and exits are S
obvious and easily identifiable. limited and main building entrances/exits are
located at the front of the site, in view of the
street. Where this is not possible, due to site
orexisting building constraints, a well defined
path is provided to the entrance/exit;
AND
524.2 All entrances/exits to buildings, are well
lit and signed, and signage includes hours of
operation;
AND
524.3 Entrances/exits are located to provide
a direct link to driveways and carparking
areas;
AND
524.4 Recessed doorways are avoided where
the recess is of sufficient size to conceal a
person. Where recessed doorways are
unavoidable, measures are used to enhance
safety, as follows-
a) good lighting installed;
b) strategically placed mirrors installed;
c) angled approaches provided; or
d) gates which restrict access provided.
025 Uses are arranged within buildings and on 525.1 Windows and main entrances are
sites to enable external areas to be monitored. positioned to allow for casual surveillance.
026 Communal open space, including 526.1 Communal open spaces, including
congregation and seating areas, is located where congregation and seating areas are situated
it can be monitored. where they are in the line of sight of windows,
doors and/or balconies of buildings, or can be
seen from a street or other public space.
027 Buildings and structures are designed to
minimise opportunities for vandalism. 527.1 Buildings or structures that are visible
from a public street or laneway-
a) avoid the use of solid fences and blank
walls which attract graffiti. Where solid
blank surfaces are unavoidable,
measures in the form of landscapin~,
creepers, murals, vandal resistant paint,
etc are used;
14-15
Business Uses Code
Page 5
0> column 1 column 2
o
t::~ Specific Outcomes Probable solutions (if code assessable)
CO~
b) use toughened glass, security screens
~ and other measures (but not including
.....
CO2 security shutters that obscure the view of
CI)!2 shopfronts) are used in windows which
O
are provided at ground level, to deter
O.g
break and enters; and
<
Q)~ Ol
c) use hardy vandal proof materials and
.::~ anti-graffiti paint are used in the
~ construction of buildings.
.E:
028 Lighting of appropriate intensities is S28.1 Lighting of appropriate intensities is
provided to maximise safety. provided ".."hlch satisfies the requirements of
Australian Standard AS 1158: Public Lighting
Code, unless otherwise specified in this Code;
AND
S28.2 External lighting of a graduated
intensity is provided which starts at a lower
level of brightness at the perimeter of the site
and rises to a higher level at the entrance to
buildings or at the centre of the site;
AND
S28.3 Lighting is directed onto the site and
away from neighbouring properties;
AND
S28.4 Vandal-resistant lighting is used in
public and publicly accessible areas.
029 Public toilets are designed and constructed S29.1 Public toilets are located in high traffic
to- areas;
a) ensure the safety of all people using them; AND
and
b) take advantage of informal surveillance S29.2 Features that may legitimise loitering,
from adjoining uses and activities, such as seating or public telephones are not
discouraging non-legitimate uses. located within 20m of toilet entrances;
AND
S29.3 Entrances to public toilets are visible
from the street, footpath and other activity
areas on the site or adjoining sites.
030 Premises have accessibility to public S30.1 Safe and convenient pathway access is
transport. provided from the site to link to existing
pathway networks that services public
transport facilities;
OR
S30.2 Direct pathway access is provided to
the public transport facility if the facility is
contained on site or within 50m from the
property boundary.
031 Business Uses are designed and S31.1 Safe and convenient cycle access to
constructed to encourage users of the and from the site from the existing road and
-develepment to access the site by means ef.-foot bicyele netwerk, and safe bieycle movemeAt
or bicycle through provision of appropriate end-of- within the site is provided;
trip facilities including bicycle parking and AND
14-16
Business Uses Code
Page 6
column 1 column 2 0)
c
Specific Outcomes Probable solutions (if code assessable)
c::
shower/change rooms. 531.2 Secure and convenient parking space
for bicycles is provided on site in accordance
~~
Q~
with AS2890.3 Bicycle Parking Facilities and
(0.9
Figure 14-1 Minimum Requirements for CI).l2
Bicycle Parking; O
AND O~
531.3 Where at least 5 bicycle parking <:
E
spaces are required in accordance with Figure Q)~
14-1 Minimum Requirements for Bicycle
~~
Parking, end-of-trip cycle facilities are
~
provided at the following rate:
a) 1 locker per 2 bicycle parking spaces; and
b) 1 shower cubicle with ancillary change
rooms per 10 bicycle spaces or part
thereof;
AND
531.4 Bicycle parking spaces and cyclist
facilities are designed in accordance with
AUSTROADS Guide to Traffic Engineering
Practice, Part 14 -
Bicycles, Section 10;
AND
531.5 On-site pedestrian facilities such as
seating and shade structures are provided in
developments for the convenience of persons
walking to the site.
Figure 14-1 Minimum Requirements for
Bicycle Parking
Use Minimum bicycle
parking
Commercial 1
bic]’cle parking space per
thereof of
Business SOm or part
ross floor area.
Entertainment & 1
SOm
bic]’cle parking space per
thereof of
Dining Business or part
ross floor area.
Industrial 1 bicycle parking space per
Business Type 2 100m2 or part thereof of
ross floor area.
1
Retail Business
bic]’cle parking space per
thereof of
Type 1 (if not a SOm or part
roadside stall ross floor area.
Retail Business 1 bicycle parking space per
Type 2 100m2 or part thereof of
ross floor area.
Retail Business 1 bicycle parking space per
Type 3 100m2 or part thereof of
ross floor area.
Retail Business 1 bicycle parking space per
Type 6 100m2 or part thereof of
ross floor area.
Retail Business 1 bicycle parking space per
Type 7 100m2 or part thereof of
ross floor area.
5ite facilities
032 Waste storage areas, external storage 32.1 Waste storage areas, external storage
areas and lading aOCKsao not aetract frOm the areas and loading ocks-are situated to the
visual amenity of the streetscape or cause rear of the building or under the ground;
nuisance to ad.oinin roperties. OR
14-17
Business Uses Code
Used in these records
Development Application part 9 of 10 Business Code - MCU13/0092Related documentApplication case desk ↗
About this file
- File size
- 3.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.