Council archive · source document
Existing development approval · MCU22/0154.01
Plan No. Rev. Plan/Document Name Date
DA200-B B Proposed ground level plan prepared by DT Architect 08.02.2023
DA201-C C Proposed upper floor plan prepared by DT Architect 08.02.2023
DA202-A A Proposed section prepared by DT Architect 19.01.2023
DA203-B B Proposed elevations prepared by DT Architect 08.02.2023
DA204-B B Proposed elevations prepared by DT Architect 08.02.2023
DA400 - Finishes schedule prepared by DT Architect 19.01.2023
Building Appearance
3. Ground floor shopfront glazing along all frontages must be fully transparent to a
minimum of 65% of the street frontage to allow passive surveillance and encourage
social interaction and must be provided at full height (floor to ceiling).
4. Any security screens on the premises must consist of grille or translucent screens and
not solid shutters, screens or roller-doors.
5. All mechanical equipment and other service infrastructure located on the site must be:
a. located not less than 2 metres from a property boundary.
b. fully enclosed or screened such that they are not visible from the street frontages
nor adjoining properties. Roof materials must be non-reflective and designed with
colours and styles to minimise the visual impact of the development.
Weather Protection
6. Street awnings must be provided along the full length of the western, eastern and
southern frontages as shown on the approved plans. The awnings must have a minimum
width of 2.4 metres from the building line or the same unless otherwise approved and
must be designed to provide continuous solar and rain protection and promote all
weather activity.
7. All ground floor shopfront glazing must be protected against vandalism by the use of a
form of safety glass such as toughened or laminated glass.
8. The eastern balcony area above ground floor must not be enclosed by permanent
fixtures such as shutters, louvres, glass panelling or the like.
9. During operating hours, pedestrian areas and entrances/exits to all stairwells, lifts,
foyers and public toilets must be well lit with vandal resistant lighting and with intensities
to satisfy the requirements of Australian Standard AS1158 “Public Lighting Code”.
Lighting must be designed to reduce the contrast between shadows and well-lit areas.
10. The approved use must not operate outside the hours of 6am to 10pm seven days a
week, except for Food and Drink Outlet which may operate on Friday and Saturday until
12 midnight.
11. The requirements of this condition must be included in the Community Management
Statement for any body corporate for the subject site.
Operations
12. The operation of the food and drink outlet and associated activities must not result in
environmental nuisances such as noise, visual or odour impacts that unreasonably
diminish the amenity of the area or surrounding uses.
Page 2 of 8
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Existing development approval.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.6 MB (small file)
- File type
No other editions are linked here.