Working Drawings - Meldrum 13-10-21
400 20340
00
PARAPET 1 7.3 455
RL 2. Window & Door Schedule
G L1
N All doors and window sizes are approximate and are to be checked on site.
All doors and windows in powder coated aluminium.
Use safety glass to bathroom and other areas as required.
2600
All glass to be clear unless state otherwise
Set windows and doors to 2700mm or 2400mm unless noted otherwise.
All doors and windows as per engineer's wind load requirements.
** All measurements are height x width.
6184
FR
GARAGE DOORS
GD1 2300 x 5200 tilt-lift door lined with timber strips to detail
FR FR BASEMENT DOORS
D1 2400 x 1270 pivot glass door set at 2400
PARAPET
GROUND LEVEL DOORS
7950
D2 2800 x 1400 pivot frameless glass door, integrated with W3 set at 2800
1940
D3 2800 x 3700 2 panels of glass doors XO set at 2800
D4 2800 x 5140 3 stacking glass doors XXO set at 2800
8699
GROUND LEVEL WINDOWS
W1 2800 x 430 5 fixed glass windows set at 2800
2427
W2 2800 x 340 2 fixed glass windows set at 2800
00 W3 2800 x 390 2 fixed glass windows set at 2800
1 7.3 50
RL 1 0.5 W4 2800 x 960 single panel glass louvre set at 2800
L
NG W5 2800 x 1410 + 725 silicon butt corner window integrated with D3 set at 2800
VERIFY SIZE OF ALL W6 800 x 800 single panel satina glass louvre set at 2400
ROOFS ON SITE W7 1700 x 800 single panel glass louvre set at 2700
W8 1700 x 800 single panel glass louvre set at 2700
DOWN PIPES AND ROOF DRAINAGE W9 800 x 800 single panel satina glass louvre set at 2400
LOCATIONS ARE SUGGESTED ONLY
W10 1500 x 2400 sliding glass window XO set at 1200
AND BUILDER SHOULD ENSURE
FR ADEQUATE STORMWATER FALL AND W11 2700 x 1400 2 panels satina glass louvres set at 2400
PARAPET DRAINAGE AS REQUIRED W12 2800 x 2050 fixed glass window set at 2800
6600
6600
W13 1500 x 2400 sashless sliding glass window XX set at 2250
KEY
UPPER LEVEL DOORS
ROOF VOID ROOF VOID DOWN PIPE FR CONCRETE FLAT ROOF
DP D5 2800 x 5500 3 panels of glass doors extended track integrated with D6 XXO set at 2800
SPITTER D6 2800 x 5200 3 panels of glass doors extended track integrated with D5 XXO set at 2800
S PD PLUMBING DUCT
D7 2800 x 3700 2 panels of glass doors XO set at 2800
00
.0 FALL DIRECTION
L 17 96 RL FINISHED LEVEL
R
L 9.5 RH RAIN HEAD UPPER LEVEL WINDOWS
NG N GL NATURAL GROUND LEVEL W14 2800 x 3330 fixed glass window set at 2800
W15 2800 x 5080 4 panel glass louvres set at 2800
2390 2390
W16 2800 x 1310 + 725 silicon butt corner window integrated with D7 set at 2800
W17 1500 x 2230 fixed satina glass window set at 2400
500 500 500
W18 1200 x 1110 satina sliding glass window OX set at 2400
W19 600 x 1500 satina sliding glass window OX set at 2400
600 6280 5380 8480
W20 780 x 4100 fixed glass window set at 1710
20740
ROOF PLAN
PAUL CLOUT DESIGN GENERAL NOTES: CLIENT NAME: Meldrum, Guy & Sue
SITE ADDRESS: 4 Tristania Drive, Marcus Beach
Suite 3, 44 MARY STREET, NOOSAVILLE Use written dimensions only. DO NOT scale drawings. Contractors to verify all
PO BOX 152, NOOSAVILLE, QLD 4566. dimensions on site prior to commencing works. Site location to engineer's DRAWING TITLE: ROOF PLAN & WINDOW SCHEDULE
BSA LICENCE: 1066417 requirements. These drawings are to be read in conjunction with engineer's
design and details, the accompanying building specification and schedule of DRAWING DATE: 13/10/21 SCALE: 1:100 on A3 DRAWING No:
PH: (07) 5440 5388
[email protected] paulcloutdesign.com.au
finishes. If in doubt, please request clarification. DO NOT ASSUME. STAGE: WORKING DRAWINGS 04.0