Skip to the record
Accept no imitations.

Council archive · source document

Amended Plans · 172007.545.02

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
                                            site boundary




                                                                                                                                 site boundary
               existing awning beams
                     & cross-members
                        to be removed
                                                                                                                                                 suite 2
                                                                                                                                                 46 mary street
                                                                                                                                                 noosaville qld 4566
      existing awning columns (4no.)
                      to be removed                                                                                                              po box 613
                                                                                                                                                 noosa heads qld 4567
                existing balustrade to
                 Upper Level Terrace                                                                                                             telephone        07 54473255
                       to be removed                                                                                                             facsimile        07 54473299

                                                                                                                                                 inf [email protected]

                                                                                                                                                 www.ct-design.com.au

                                                                                                                                                 building designer licence 1016347

                                                                                                                                                 This drawing is to be read in
                                                                                                                                                 conjunction with Engineers Drawings
                                                                                                                                                 & Reports.
                                                                                                                                                 Construction to comply with all
                                                                                                                                                 relevant SAA & BCA Codes &
                                                                                                                                                 standard Bldg By-law 1975 & as
                                                                                                                                                 amended.
                                                                                                                                                 Verify all dimensions on site prior to
                                                                                                                                                 commencement of any works. These
                                                                                                                                                 drawings are not to be used for
                                                                                                                                                 scaling. Copyright for design &
                                                                                                                                                 drawings remain the property of
                                                                                                                                                 the authors.

                                                                                                                                                 CONSULTANTS
                                                                                                                                                 .

                                                                         EXISTING SOUTH ELEVATION                            1:100               Structural Engineer
                                                                                                                                                 .
                                                                                                                                                 SCG Consulting Engineers
                                                                                                                                                 Contact: Matt 07 5455 5604
                                                                                                                                                 [email protected]
                                            site boundary




                                                                                                                                 site boundary
                                                                            new metal flashing/gable infill, paint finish,                       .

                                                                            refer to External Finishes Schedule                                  Surveyor
                                                                                                                                                 .
                                                                                  new RHS beam, in line with beam over,                          Hass Survey
                                                                                  refer to Engineers Design                                      Contact: Phil Hass 0421 039 204
                   new awning to top of                                                                                                          [email protected]
                       awning structure,                                                                                                         .

           refer to Proposed Roof Plan                                                                                                           Building Certifier
                                                                                                                                                 .
                                                                                                                                                 Suncoast Building Approvals
                new RHS fascia beam,
                                                                                                                                                 Contact: 07 5443 7288
                   refer to Engineering                                                                                                          [email protected]
              & Ext. Finishes Schedule
   new zip track drop down sunscreens
to perimeter of awning structure (5no.),                    dropdown
                                                            zip screen
               refer to Series 700 Detail

new awning columns (4no.) & beams,                                                                                                               C2 Issued for Construction
          refer to Engineers Design                                                                                                              Revised 05.05.2021
                                                                                                                                                 for Lodgement of Variation
                                                                                                                                                 Project
       new frameless glass balustrade,
              refer to Series 700 Detail                                                                                                         PROPOSED
                                                                                                                                                 RENOVATION
             NOTE: paint finish to new                                                                                                           Location
                 steel awning structure,
            (including columns, beams                                                                                                            25 ARKANA DR
            & cross-members), refer to                                                                                                           NOOSA HEADS Q
Ext. Finishes Schedule for paint colour
                                                                                                                                                 Client
                                                                                                                                                 F & R SANDERS
                                                                                                                                                 Drawing Title
                                                                                                                                                 SOUTH ELEVATIONS

                                                                                                                                                 Scale                    Date
                                                                                                                                                 as shown @A3 2020
                                                                                                                                                 Drawn By                 Job No:
                                                                                                                                                 SC                       2010
                                                                                                                                                 Drawing No.              Issue No.

                                                                         PROPOSED SOUTH ELEVATION                            1:100               WD.504 C2

Used in these records

About this file

File size
2.0 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Amended Plans.pdf · 2.0 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.