7 6 5 4 3 2 1 design group
16,110 3,400 4,290 3,990 1,100 3,330
NRG
building design + interior architecture
EXT. FINISHES LEGEND
TD BAL TD BAL AL REN MR1 TF join truss join MR1 TF truss AFW TS SP BLK REN BLK REN TS REN BLK
AS aluminium screen.
insulation AL aluminium louvres, refer sched.
insulation
8M HEIGHT LIMIT 7° ASD aluminium sliding door.
AFD aluminium framed door.
3°
UPPER CEIL R.L. 19.300 UPPER CEIL R.L. 19.300
AFW aluminium framed window.
refer engineer BAL1 balustrade-(no refers to type).
PLY PLY PLY
W09 BLK masonry blockwork.
PB
W19 box box gutter ref. eng.
ALFRESCO LINK ENTRY
3,100
artwork
KITCHEN
2,700
brick feature brickwork
T.O.BAL R.L. 17.200 W17
DISPLAY
C carpet
pendant lights
J12 conc off form concrete.
WD.703 J11 join J09 D03
UPPER FFL R.L. 16.200 9 TF UPPER FFL R.L. 16.200
MAIN CEIL R.L. 15.900 FC 8 W01 CS concrete slab.
7
6 STAIR DP down pipe.
5
4
PB PB PB FT conc FT
LOUNGE W05 BED 2 join
HALL BATH 3 DS driveway slab.
2
ENTRY
DP
black paint to u/s acoustic void
1
D12 fibre cement external cladding.
2,760
of joists
COURT
4 FC
2,780
SP
ASD insulation 3
T.O.BAL R.L. 14.140 robe join 2
1 FG fascia gutter.
fill
TD TF FT FT FT1 floor tile - (no refers to type).
seat SF SF
MAIN FFL R.L. 13.140 fire fireplace
FC waterproof
membrane/ drainage flue flue kit
7 timber sleepers
& protected termite
HR
5
6
barrier to BCA/AS
GS garage slab.
SP 4
NGL
2
3 SF SF SF
agg. drainage to
HWS hot water service.
SF
POOL R.L. 11.260 1 stormwater HR handrail.
pavers / steps
SF
LPG LPG gas bottle.
NGL natural ground line
SF -
NRG Greenboard cladding
NOOSA COUNCIL NRG
MR1 metal roof - (no refers to type).
APPROVED PLAN PW parapet wall.
MCU17/0031 19 MAY 2017 PS patio slab.
rainwater head, ref. engineer
SECTION C
RWH
NRG NRG BLK RWT rainwater tank.
SCALE 1:100 @ A3 TS BLK REN FT MR1 REN AL flue REN REN AFW SBJ AFW FG FC join TF MR1 join FT truss MR1 AFW awning
SBJ silicone butt jointed glass.
SP structural post, refer engineer.
SF structural footing, refer engineer.
insulation TD timber deck.
TF timber floor.
tile feature tiling
UPPER CEIL R.L. 19.200 TRW timber retaining wall.
VG valley gutter.
PB PB
D04 W13 SF/LF/
BA/C1 Working Documentation 08.05.17 AB/NB
WIR ENS
2,700
no. issue / amendment date initial
robe robe W14 client
W15 J & E Kelly
W09 W10 J19
project
UPPER FFL R.L. 16.200 Kelly Residence
ENTRY MAIN CEIL R.L. 15.900 location
DP
16 Piper St, Peregian Beach
acoustic PB REN
D11 D13
SECTIONS C & D
PB
GARDEN
join
insulation NRG
W01 REN REN
GUEST BED GARAGE
2,760
4 Lee Foster / director Scott Falconer / director
3 BLK NRG p - 0424 620 247 p - 0422 483 159
2 design group e - [email protected] e - [email protected]
1 the aboda design group Level 2 1794 David Low Way Coolum Beach,
trust *ABN 56 266 884 746 Q. 4573. PO box 2449 Noosa Heads Q 4567
TF J07 GS t/a aboda design group *BSA License -1175604 *www.aboda.com.au
J06 join
*This drawing is to be read in conjunction with Engineers Drawings & Reports
GARAGE FFL R.L. 13.140 *Construction to comply with all relevant SAA & BCA Codes & standard Bldg
By-law 1975 & as amended.
*Copyright for design & drawings remain the property of the authors.
SF fill *Verify all dimensions on site prior to commencement of any works.
fill *These drawings are not to be used for scaling.
scale as shown @ A3 issue
drawing no.
SECTION D WD.602
SF
SF SF SF
BA/C1
SCALE 1:100 @ A3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plan MCU17-0031.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.