Original source · versioned page text
2020-10-12 GC Agenda - Item 6 - Attachment 1 - Proposal
Very large file: it may take a few minutes
The original of this document is very large (21.7 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
fall
KIN
REV DESCRIPTION DRN DATE
A MCU DA Issue MS 25.02.20
B MCU DA Issue MS 02.03.20
C MCU DA Issue MS 06.03.20
D Client Revisions MS 14.04.20
DP
Pla
E MCU DA MS 05.08.20
nte
Information Response
r
BO
GP der
Un
Fir
Ex tair
CO
eS
isti 02
U2
L
Ex
ng
n
Ne
16
isti (no
ree
Sc
w
ng wor
1:2
New, reconfigured entry / exit fire
Provide tactile indicators
escape stairs, ramps and
0
Re ks)
as per AS 1428.4.1 and
ram
GP der
platforms to conform with current
Un
NCC requirements
p
sta
building standards to future detail
Pla
ura
HY
nte
HY
Restaurant
D
D
r
n
entry
t
CO
L
CO
Ga
Screen
te
L
CO
1700
L
1257
100 x 25 powdercoated Provide 100 x 25 anodised Stair
up
aluminium screen and aluminium screen between exit
DP
KE
gate to fire exit walkway and existing planter New 1:20 ramp
X
dn
90
New frameless glass balustrade
with anodised aluminium
10
Duct
La
uprights and handrail, fixed to
nd
new floor structure
Screen
ing
1950 90 1950 90 2800 90 1815
Fe
PW
Ma
ma
CO
le
2530
D
Sto
RL 5.630
le
RL 5.630 RL 5.630
Stair
L
dn
re
RL 5.630
CO
L
DP
Screen
90
GD GD GD
DP
DP
CO
CO
Trellis Trellis
Generally throughout:
DP
L
L
DP
Feature frameless glass 100 x 25 powdercoated - New render and paint finish to all external walls
Provide new wall
enclosure to existing duct
balustrade fixed to edge of aluminium screen fixed - New anodised aluminium (25µm coating)
stair treads as per future detail to slab edge
sliding doors to terraces / balconies
Feature frameless glass - New anodised aluminium (25µm coating) windows
Downpipe to be concealed Line of new roof over
within structural column, to
balustrade fixed to slab edge.
to main stair and
- New frameless glass balustrade with
Continue panelling beyond
Line of new roof over to
future detail, T.B.C.
upstand wall on ground level
landing shown dotted anodised aluminium (25µm coating) uprights
amenities shown dotted - New tiles to walkways, terraces and balconies
LEVEL 1
Scale 1:50
Suite 2,
Cnr Gard
Alexand
PO Box
P 07 54
admin@
SUNCOAST RESORT BUSINESS CENTRE
SUITE 2 CNR GARDAK ST & SURF RD
ALEXANDRA HEADLAND Qld 4572
PO BOX 6232 MAROOCHYDORE BC Qld 4558
PH : 07 5443 5028 FAX:07 5479 2380
ABN 23 123 917 724
EMAIL: [email protected]
project
PROPOSED ALTERATIONS &
ADDITIONS TO EXISTING
RESORT BUILDING
for
NETANYA RESORT
at
75 HASTINGS STREET
NOOSA HEADS
drawing
DETAILED AREA - 'SAILS'
ENTRY / PARK ROAD
FRONTAGE
Existing walkway planters Existing walkway planters New feature entry / exit stair to AS SHOWN
Downpipes off new roof to be Feature powdercoated 100 x 25 powdercoated Powdercoated aluminium Existing 'Sails'
and footpath to be Existing 'Sails' restaurant and footpath to be common landing. Provide frameless date 5/08/2020 drawn JP scale @A1
concealed within structural aluminium trellis screen with aluminium screen and gate (Plant sun hood / box frame restaurant behind;
reconfigured / added to suit behind; no works reconfigured / added to suit glass balustrade to anodised batten
column, to future detail, T.B.C. vertical landscaping on wires area behind) to future detail surround to new window no works
substation doors and gates substation doors and gates screening to street front
drawing no. 19021 SD60.09 revision E
Copyright of this document remains the exclusive
N
property of SPROUT ARCHITECTS PTY LTD
ABN 23 123 917 724.
Contractors are to verify all dimensions and levels on
site prior to commencing. Report all discrepancies to
the Architect. Use figured dimensions in preference
0 5 10 to scaled.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.